Laserfiche WebLink
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed Joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed 1_1180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -In -place concrete may be provided in composite lintel In lieu of concrete <br />masonry units. <br />9, Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.20-0630.16 and 20-0630.15. <br />11. The exterior surface of lintels installed In exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12, Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load Applied horizontal load �� • O <br />Safe vertical load + Safe horizontal load _ <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />-WWI <br />LENA <br />Mwm <br />M. <br />8F441B/1T8F401B/1T 8RF400B/1T 8F321B/1T <br />FORM At GROUT SOLID <br />4 �a <br />O #5 BAR CONT. <br />8F12-1B/1T <br />O <br />"V" LINTEL DETAIL <br />SCALE - N.T.S. <br />MEN <br />F = FILLED WITH <br />GROUT / <br />U = UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @� BOTTOM <br />OF LINTEL CAVITY <br />8F 16- <br />B/1 T <br />a <br />tNOMINAL <br />QUANTITYOFr <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINALJ <br />HEIGHT <br />MATERIALS <br />c-if p�lintels = 3500 psi. <br />2. fc prestressed lintels - 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 318" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 <br />MIN..REBAR(1)(1) <br />AT TOP <br />REQ'D <br />LEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />- <br />4 • <br />4 <br />.M.U. <br />#5 REBAR AT TOP <br />a • <br />MIN. (1) REO'D <br />1-1/2" CLEAR <br />• <br />° <br />4 <br />GROUT <br />� <br />• <br />_ <br />n J <br />m to <br />C.M.U. <br />-45 REBAR AT <br />~ J <br />• <br />BOTTOM OF <br />LINTEL CAVITY <br />OF <br />o <br />-BOTTOM <br />X <br />o Lu cj <br />REINFORCING <br />a O 9 <br />r` <br />- <br />7-5/8"ACTUAL <br />PROVIDED IN <br />LINTEL <br />o �t in <br />1 b r * <br />5 REBAR AT BOTTOh <br />8" NOMINAL WIDTH <br />(VARIES) <br />LU ppr+ <br />a. e <br />AS INDICATED <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />LINTEL PLAN NOTES: <br />1. THIS PLAN IS TO BE USED FOR STRUCTURAL <br />INFORMATION ONLY. <br />2. UNLESS NOTED OTHERWISE ALL LINTEL DEPTHS ARE <br />TO BE ASSUMED TO BE 16" MINIMUM DEPTH. <br />3. THE NUMBER OF COURSES OF MASONRY REQUIRED <br />BETWEEN THE LINTEL & THE BOND BEAM SHOULD BE <br />COORDINATED WITH THE ELEVATION DRAWINGS <br />4. THE CONTRACTOR IS RESPONSIBLE FOR <br />COORDINATING THE PROPER LINTEL HEIGHT. <br />5. LINTELS AT GARAGE DOOR OPENING ARE MINIMUM <br />DEPTH REQUIRED FOR THE DESIGN LOADS. THE <br />DEPTH MAY BE INCREASED IF REQUIRED FOR <br />PROPER LINTEL HEIGHT,G.C. COORDINATE. <br />POWER STEEL LINTEL IS AN ADEQUATE <br />SUBSTITUTION @ ALL LOCATIONS UNLESS <br />NOTED OTHERWISE AT OPENING LOCATION <br />�F� OF <br />4'-6" LL 4'-6" LL <br />(1E) <br />6-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: Y4"=V-0" <br />C'l+ <br />'O <br />y W <br />L <br />V • G� O <br />eo as D x <br />u= a <br />N to C= <br />N Cl Q Co <br />a ., <br />�y a' <br />c <br />CD Q <br />os a <br />7 O- <br />c E <br />l0 <br />01 <br />.�i?t��lAoi <br />;- 1 yIV <br />To the best of the Engineers knowledge, information and bell ef, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />fA <br />E <br />a 8 $ <br />V w Co <br />6,�N0 <br />u <br />0 J LL LL d <br />0. <br />{a� <br />= <br />o <br />d' <br />W °i °' m <br />Z Co <br />CZILd <br />OU <br />Z 0 <br />Wcr) <br />I V <br />_r) <br />Z 8S <br />Z n <br />Q <br />d � <br />t/1 Z v <br />ty <br />N <br />LU <br />OW <br />S <br />g�2 <br />w � <br />V <br />U <br />C <br />Q Y <br />• <br />N m <br />M <br />0 <br />W <br />E <br />E <br />Q <br />Fi <br />oa <br />Z <br />g <br />N �- <br />o <br />`" 8 <br />�W <br />L <br />ro <br />`O <br />a <br />m <br />F <br />Z <br />Z <br />ro <br />y0 <br />iK a <br />> <br />�i <br />z <br />c <br />U <br />�o <br />E <br />�- <br />S <br />.0O <br />� <br />LO <br />O <br />Q <br />CU <br />(M <br />Cr <br />O <br />m <br />co <br />IN <br />al <br />o <br />o <br />04 <br />o <br />a) <br />L0 <br />M <br />M <br />t- <br />Z <br />Z <br />W <br />E T-- <br />.. <br />m <br />a <br />U Q o <br />JOB <br />NO: 22-06464 <br />SCALE : AS NOTED <br />SHEET NO. <br />8 <br />W <br />C� <br />Q <br />