Laserfiche WebLink
vt <br />I Pi <br />0 <br />r5(' <br />eT <br />a <br />O <br />FL <br />E <br />LZ <br />S <br />0 <br />N <br />4Z <br />LO <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance With ILL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit Is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided With a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />[10W.P. WEATHERPROOF DUPLEX OUTLET <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />fLOh SPECIAL PURPOSE OUTLET <br />4a DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />24 FOUR-WAY SWITCH <br />$R RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 WALL MOUNTED LIGHT FIXTURE <br />O RECESSED LIGHT FIXTURE <br />P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />Q EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />i9 PUSH BUTTON SWITCH (OPTIONAL) <br />i0 PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />fV1J ELECTRIC METER <br />owl ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />150A/200A INDOOR <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />to lights & outlets <br />to appliances and GFI <br />to WH <br />o Range <br />a HVAC <br />so=2ro <br />2oo=4I0 In 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND IQjj <br />SERVICE BY POWER CO.—,__ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />I, j 2,t <br />A� �) Q VTo <br />PLUMBING RISER_ <br />NOTE: PLUMBING RISER IS SCHEMATIC TO SCALE: NTS <br />BE VERIFIED WITH PLUMBER <br />15'-0" <br />4. RECEPT. VERIFY METER <br />FOR ALARM LOCATION WITH <br />BUILD R WP H.B. <br />SYSTEM f-1 A GFI I <br />--------- r IRRIGATION <br />GFI '1 VERIFY LOCATION GFI aZ-W A.F.F. <br />ELECTRICAL PANEL I I I <br />OWNER IssW ITE <br />T 1. / <br />2 CAR GARAGE <br />1—J.._-T - <br />I <br />GFI FOR I <br />/ ROUGH -IN FOR / I GAR. DOOM I I <br />/ OPT. CLG. FAN/ 7 --�— I GFI I I <br />LIGHT PRE -WIRE GFI @ 44" I I I <br />A.F.F. I I I <br />S.D. / / / dVP -----------` I- It <br />I I I <br />It <br />C.M I 0 T. OPT. <br />I / e D. Ill 1 i I I I <br />I <br />L------------ <br />AHU GFI @ 44" <br />nil I <br />A.F.F. <br />FAMILY R M ---- _ - <br />�� ENTRY <br />j ROUGH -IN FOR + <br />OPT. CLG. FAN! --�- DB . WP <br />I LIGHT PRE -WIRE — GFI <br />------- <br />I U.C. OUTLET - - - - - - - <br />I FORDW--------------- 3 <br />I S.D. _ _ ` f S.D. <br />U.C. OUTLET <br />I I i <br />rI <br />M � I � - _- � 1 OPT. <br />J <br />1 <br />GFI REF. - -- - <br />F <br />CBEDROOM 2 S.D.PA CAFE GFi--: ' BEDROOM 31 BEDROOM 4 <br />AT>�I <br />� D.W. _ , - - - GFI / 1 <br />\ i 'IN I / / / 11- \ %ROUGH -IN FOR <br />1 K / DIS � ---- � �% 1 <br />-} I OUGH-IN FOR / � � -,- - t - !��� OPT. CLG. FAN! <br />Ll.!C. SWIP I OPT. CLG. FAN/ W 1 - LIGHT PRE -WIRE <br />IP — ` \ �__ �- - - ._E LIGHT PRE -WIRE / I I - <br />PENDANT AS \ i j 1 ji - -- 6/ 1 (/ <br />PER SPECS ROUGH -IN FOR I <br />OPT. CLG. FAN! I <br />i <br />14) \ � LIGHT PRE -WIRE <br />103 <br />DEDICATED RECEPTACLE <br />H.B. FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />ELECTRICAL PLAN - ELEV-Al_ <br />N <br />C%A0 <br />co w <br />y p <br />s�L o <br />= toaQDoK <br />M O >— <br />en <br />4-�tv�C <br />w <br />O1 "r <br />=ta <br />� 3 ` <br />ttd y ar <br />1_ <br />iti o <br />W <br />6 <br />c E <br />to o <br />o. u <br />0 <br />N <br />N <br />N <br />M <br />�n <br />0 <br />To the test of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code <br />- <br />Residential 7th Edition. Engineer's signature and seal <br />is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />0) <br />W <br />N <br />LQ <br />o <br />6 co <br />0) <br />a <br />"S' 'Z L. s <br />LL <br />Z <br />cqLLLLLL a <br />0' a <br />pCm <br />OC <br />W <br />�2O0, m w <br />LL <br />MZdk <br />N 04 <br />Z <br />OU <br />W <br />00 <br />N <br />Z <br />z <br />Z n <br />¢ $ <br />J — <br />XC.9 <br />c <br />.j <br />,, g <br />N <br />�ro <br />" <br />OOf � <br />O <br />�21 <br />2� <br />g <br />� <br />E <br />�� <br />�� <br />aLA- <br />��9 <br />Z <br />_Ely <br />to <br />t_to <br />g <br />Z <br />CO <br />yJ Q) <br />y{ <br />g■ <br />W <br />3 <br />v <br />-M <br />1O <br />(0 <br />LO <br />U-) <br />ai <br />rn <br />Lo <br />c� <br />Q <br />:3 0 <br />M <br />r <br />� <br />N <br />M <br />Ln <br />r <br />O <br />N <br />QI <br />0 <br />04 <br />cD <br />,= <br />Ln <br />T <br />QLO <br />T <br />ti <br />c, T' <br />Z <br />C <br />T' <br />B <br />v :� <br />C <br />c <br />FL <br />1U a <br />¢ p <br />-j <br />JOB <br />NO: <br />22-06464 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />