Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH —,� WALL SHEATHING <br />Q <br />41 <br />L•1. ... x^"z . I I . �� p I <br />16GAx1-1' 2" LONG ('3l4""-1"CROWN) - If! 9 : <br />STAPLES (cz} 6"' O.C. VERT BETWEEN i I MAX'� I I 1 — 16GAx1-112"' LONG (3,"4'"-1" <br />STUDS (NOTED THUS:—) - OFFSET I I --I� I I I CROWN) STAPLES rc� 6" <br />Slf APLES BETWEEN STUDS AS SHOWN - _.-... _ W_..-........_._ O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV, 09.24.21 SCALE: 14" V-0" <br />'DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 103.7.1 LATH' <br />""ONLY APPLIES TO LENNAR TPAIJAX** <br />LATHING ACCESSORIES: <br />ATTACHMENTS SHALL BE OF CORROSION -RESISTANT MATERIALS. <br />WOOD APPLICATION: 16 GA. x 1-1/2" LONG (3/4%1" CROWN) STAPLES @ 6" O.C. <br />VERTICALLY/HORIZONTALLY INTO FRAMING MEMBERS. <br />MASONRY APPLICATION: CONCRETE STUB NAIL, 3/8" (10 MN`i) HEAD DIA. MIN. @ <br />6" O.C. VERTICALLY/HORIZONTALLY OR COMPATIBLE ADHESIVES, EXTERIOR <br />GUN -GRADE, CONSTRUCTION ADHESIVE WITH 1" DABS @ 6" O.C. OR IN A <br />SEMI -CONTINUOUS BEAD BETWEEN THE SOLID PLASTER BASE AND THE SOLID <br />PORTION OF THE KEY ATTACHMENT FLANGE. <br />CONTROL JOINTS: INSTALL CONTROL JOINT LATHING ACCESSORIES IN <br />CONFORMANCE WITH C1063. LATH SHALL NOT BE CONTINUOUS THROUGH <br />CONTROL JOINTS, BUT SHALL BE STOPPED AND TIED AT EACH SIDE. <br />ALL ACCESSORIES SHALL BE IN ACCORDANCE WITH THE LATEST ASTM C1063 & <br />ASTM C1861. <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />5'-0" <br />STUB -OUT FOR "' <br />GAS METER 0 , <br />0 <br />N <br />H C G <br />000 <br />o J LO <br />�8 <br />g <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"*ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY'"* <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16"-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />151-4" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Cr: <br />w <br />00 <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + �, <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ 4 <br />+ + <br />+ <br />+ + <br />+ <br />+++ <br />+ <br />+++ <br />(�1 <br />+ + <br />+ <br />(61, <br />" <br />+ <br />+++ <br />+ + <br />+ + <br />. <br />+ <br />+ + <br />+ <br />+ + <br />+++ <br />+++4 <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + o <br />+ + <br />+ + + + + <br />\++ <br />+ <br />+ <br />+ + + + + + + + cb <br />+ <br />+ + + + + + + + + + <br />+ + <br />++ <br />+++ <br />+++++++++ <br />+ <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />+ + + <br />8d RING SHANK NAILS @ 6" O.C. & <br />4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />+ + <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH <br />CJ� <br />\—RIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. EDGES & <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />2-3/8 INCH NAIL LENGTH <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />O <br />NOTE: I , .., .,.......,. .,.,.,,.,... ,.,.�.......,..",,..,.- ------ <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />5000s 1.8/1.7 <br />3/4" or 7/8" <br />wood panels <br />Two 3/4" wood anels or 2 x _ <br />P <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2x _+ 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _+ 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x _+ 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />-t <br />FILL CELL—\ �— STD. 90° HOOK r- BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. ) Small gap 2" min. <br />2" <br />max. � 4 max. <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit ��- <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 1Od nails required <br />web stiffener 2" min. <br />required when indicated or 4 max. <br />2x_ CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING Y" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />t. <br />DOUBLE JOIST CONNECTION top flangeuthcuts. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. higher than t snnlh <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />*Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />T1/16" <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or-20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block / <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />I Ica 9" N nrll nails nt R" n r <br />�'/ Provide adequate bearing <br />for each lapped joist. <br />Odnails SECTION @ INT. BRIG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />* 1— <br />iD CD <br />6„ A %" ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1y2' <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Use 1063" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.— <br />Round Halls 18im ter ": <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />8.875 <br />10 <br />11' <br />121, <br />'13 <br />Rectangular Hok, Side (in) <br />- <br />l <br />2 <br />4 <br />5 <br />6 <br />8 <br />9 <br />10 <br />Any 16" joist <br />Span ("'.) <br />8 <br />V-0" <br />1"-l" <br />1' 2" <br />V-2" <br />-3" <br />1'-3M <br />1'-7" <br />V-11" <br />2'-4" <br />2"-9" <br />3'-2" <br />3'-7" <br />12 <br />V-0" <br />V-1" <br />V-2" <br />V-2" <br />1'-3" <br />1' 9" <br />2'-4" <br />2'-11" <br />3'-7" <br />4-2" <br />4'-9" <br />5'-4" <br />16 <br />V-0" <br />V-1," <br />V-2„ <br />1, 2„ <br />1'-7" <br />2,_5„ <br />3.-2" <br />3'-10„ <br />4'_0„ <br />5,-7" <br />6.4" <br />7'-2- <br />20 <br />V-0" <br />1'-1" <br />1'_2" <br />1' 2" <br />2'-0" <br />3' 0" <br />4'-0"' <br />4'-10" <br />5'-11" <br />6'-11" <br />7'-11" <br />8'-11" <br />24 <br />1'-0" <br />1'-1'" <br />1'-2" <br />1'-3" <br />2'-5" <br />3'-7" <br />4'-9" <br />5'-l0" <br />7'-2" <br />8--4" <br />9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB, THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />J/ \ Filler block. <br />Nail with <br />10-1 Od nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />r r when t Web stiffeners are not required e top P required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />7. <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series Depth End Intermediate <br />BCI5000s ® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />BC16000so <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />" <br />3-16d <br />3-16d <br />14" <br />-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS T <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPSC <br />w/(22) <br />NAILS T <br />R TRUSS <br />'OP PLATE <br />LC <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />!a <br />,e <br />00 FINISH GRADE <br />SLEEVE THRU STEMS <br />SEE PLAN FOR °• a • •, <br />FOUNDATION INFO a <br />STEM FOUNDATION <br />GRADE <br />° <br />REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ,° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL. SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />or <br />IFd 1a5�I I I a <br />'llNA I I• .. _I <br />I I <br />JUL 2 1 2023 <br />rJ J <br />SEE FND. PLN. <br />SIZE & REINF, <br />Virtual Review Assist, Inc. <br />PIPE VERTICAL TWI►IIP!Pleted and approved <br />or con - a 2020 FBC 7th Editi <br />by Debra Anne Klahr PX2300 <br />TOP (2) #5's x 4'4" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE PLUMBING LINE <br />PENETRATION T i <br />- - - - - - - - - <br />----------------------- <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />71 a Fl— <br />Ad a a <br />------� . --.-- -- a/ as <br />d <br />lill- <br />° <br />SEE FND. PLN. <br />SIZE & REINF. <br />Ad <br /><h <br />N <br />N <br />r'° <br />o; <br />Ln <br />�. <br />Qz <br />®' <br />W <br />" <br />O <br />0 <br />z <br />d <br />V) N u7 — E <br />O p o <br />V C '0 <br />�iJ U <br />M ti <br />ri S <br />N V c d °' <br />4) 0 u <br />0 if: Q <br />'N W 0- <br />N i ECl) m <br />o <br />C', a <br />LU <br />LLI (DW <br />o w Lu <br />W~ Q � J Y Z Z <br />°�Ja0 U.0OLJo <br />JZLL� <br />LL Q � <br />0 ~ <br />0 0 <br />j�x 0220001 <br />0waWvoiwowwN0M�¢z0 <br />0 > <br />I_ <br />o0 <br />0OZ <br />Q�Woe0zWo�o¢ <br />00Q 0 0 a <br />H LL <br />I <br />0 <br />z W <br />0� <br />O <br />0 I..: M <br />QV)(MU-) <br />2(nUt� <br />aCM <br />00 <br />V <br />z l�- <br />W0 <br />W <br />J 0O <br />M <br />N <br />co <br />N <br />N <br />N <br />N <br />ti <br />4 <br />1 4 <br />O <br />N <br />0.0 <br />N <br />n <br />O <br />O <br />O <br />O <br />00 <br />0) <br />' <br />co <br />00 <br />N <br />O <br />NO <br />O <br />e— <br />0 <br />e- <br />0 <br />O <br />0 <br />N <br />0 <br />N <br />O <br />cV <br />(V <br />p <br />N <br />N <br />N <br />00 <br />Q <br />In <br />00 <br />er) <br />T— <br />O <br />No <br />� <br />0 <br />0 <br />O <br />� <br />O <br />� <br />o <br />CG <br />0 <br />U) <br />N�/� <br />�1 J <br />� <br />>1 <br />0 <br />0 <br />0 <br />M <br />0 <br />O <br />O <br />O <br />- <br />LO <br />1 <br />N <br />1 <br />I d I <br />LO <br />1 (01 <br />r. <br />CO <br />z z <br />—z_ O <br />OLLI <br />4--+ <br />Vo20 <br />1.-W U) <br />i_0W <br />of a- <br />.� <br />V) <br />Z <br />LU <br />LU <br />W � Q <br />= z <br />N <br />U�3� <br />00 <br />1 <br />W <br />Z <br />z <br />W cV <br />O�1W <br />N <br />a <br />v <br />Ln Z z <br />z <br />Qz <br />O <br />� <br />ry <br />z <br />U <br />OU <br />O <br />a <br />W <br />a <br />z <br />SN1W <br />z <br />z <br />W <br />M <br />N <br />O <br />0 <br />LAST PLOT DATE <br />May. 9, 23 <br />Z O <br />STRUCTURAL <br />— J <br />DETAILS <br />