Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />16GAxl-1\2" LONG (3/4%1" CROWN) <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET <br />STAPLES BETWEEN STUDS AS SHOWN <br />WALL SHEATHING <br />16GAx1-1/2" LONG (3/4"-1" <br />CROWN) STAPLES @ 6" <br />O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />10'-0" <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE 0 0 0 <br />5'-0" ¢ - <br />STUB -OUT FOR o ° o <br />GAS METER 0 o <br />U <br />O <br />N = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />'I T-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />F-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />'I T-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Thickness <br />Filler Block Thickness <br />Series <br />3/4" orp 7/8" <br />5000s 1.8/1.7 <br />el <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1l8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />60 2.0 <br />wood panels <br />2x — + 5/8" or 3!4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking + <br />1/8" gap <br />+ <br />FILL CELL STD. 90° HOOK BOND BEAM <br />cn <br />w <br />j STD. 90° CONT. #5 <br />CONBAR I HOOK ��r BAR <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />5/8" 0 <br />#5 CONT, THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D PLYWOOD FLOOR <br />COLUMN AND SHEATHING PER PLAN <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG, WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2' min. <br />2" max. nn 4 1max. <br />V <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2° min. <br />required when indicated or 4 max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGy" GAP @TOP sides by 6". <br />- Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION <br />- Birdsmouthcuts. N.T.S. <br />N.T.S. - Under 2nd floor column w/ loads <br />higher than 1.1101h <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non stacking walls <br />over squash=20 blocks and <br />require additional <br />consideration. Check <br />wall or beam below.* <br />local building <br />code for appropriate <br />1J16" <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (1 OM nails at 6" o.c. <br />QY/ Provide adequate bearing <br />for each lapped joist. <br />Od nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />Iz blocking and wall or beam below.* <br />Use 10dxY nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. -- <br />R►_ <br />�'�- <br />6 A 1 2" ROUND HOLE MAY 6 6. DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1%" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS, <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y2' <br />Any 1 6 ' joist <br />8 <br />T-9' <br />V-1" <br />,2,° <br />V-2". <br />1'-3° <br />1'-3' <br />1 'I'-7" <br />1'-'f 1 <br />2-4' <br />2 <br />3 2" <br />3 T' <br />12 <br />1'-0" <br />1'A" <br />1'-2' <br />1, 2" <br />V, 3' <br />V-9' <br />2. 4' <br />2-11" <br />3'-T' <br />4 2' <br />4-9' <br />-4' <br />T-W <br />T-1" <br />1'-Z' <br />1"-2" <br />1-7' <br />2-�S <br />3-2" <br />3-40„ <br />4. . <br />9-7. <br />6-4' <br />7 -2' <br />20 <br />1'-9' <br />1-1" <br />i' " <br />T "' <br />24Y' <br />3 C' <br />4--9' <br />41-10" <br />5-11�" <br />6' 11" <br />7'-111" <br />8' 11,. <br />1�-W <br />2-6 <br />3' -Z" <br />4-9' <br />9-10'" <br />7,-2° <br />8-4" <br />'-6' <br />10'g' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7.1y2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist B Bring Location <br />Series De th End Intermediate <br />BC15000s® <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI6000s® <br />BC16500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60e <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />1 2-8d <br />5-8d <br />16" <br />1 2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />SIMPSC <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />Joist <br />When joists meet over wall, provide <br />13 minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Joist hanger <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) I I Inl I II II I it <br />Nail with 10- 10d nails. <br />Install tight to top flange. SLEEVE THRU STEM ° <br />a <br />SEE PLAN FOR °. a .. a . <br />FOUNDATION INFO ° <br />°, <br />STEM FOUNDATION <br />GRADE <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. _ _ <br />Install tight to to flange. I=� I I=III- <br />9 Pr—rir—iir—T <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />REINF. SEE PLAN <br />�A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12/ METAI2TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />'�0 LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PVC OR SCH40 SLEEVE <br />PI HMRING I INF <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 °_ <br />d 4 °O" ° °a IG <br />i ��1=1 a a d a 11=1�1 III) <br />a _I I II I II <br />1I— <br />SEE FND. PLN. <br />SIZE & REINF. <br />M <br />N <br />0 <br />w ati o <br />.� <br />c eo c•a <br />X <br />R% G i <br />-0 CN S <br />y C <br />V i <br />�CR.T <br />a� <br />2 E <br />C)- U <br />M <br />N <br />0 <br />N <br />N <br />0 <br />0 <br />F Q. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />W <br />Il- <br />a_ <br />d E <br />o 0 <br />/� <br />V <br />2 co N Co <br />0 <br />in r J <br />0 <br />Q <br />r> v # u <br />N J <br />C J � W <br />J L LL 6. <br />_ aW <br />Z <br />?5 <br />99� <br />W <br />:3 m 04 � 0 <br />ti o <br />W <br />LL Z <br />��°j6' m J <br />N N Z Q <br />ZN <br />do °ate' o <br />W <br />00 <br />(D <br />V M M <br />N <br />o g <br />N <br />z o � <br />E3 <br />WV) <br />N <br />z a <br />i'1 C <br />J o <br />a--J <br />fL5 <br />W <br />� <br />U <br />0 <br />c� <br />UJ <br />its <br />E <br />O <br />m t <br />t� •., <br />_ <br />U 'o y <br />Of 'D <br />m <br />a <br />w <br />cc <br />M <br />0O 3 <br />z <br />4 <br />U_ <br />0 <br />zo <br />� <br />>N <br />zo <br />14E <br />CL O <br />U <br />z <br />oa <br />F- rp <br />— <br />o E <br />g <br />��i <br />00 <br />o <br />oQ <br />< <br />Xz <br />�� <br />ITT <br />C.0m <br />o <br />�� <br />2 c <br /><om0 <br />0Qo <br />Y <br />0 <br />z <br />m J <br />hm <br />Qz <br />Z2 <br />8 <br />0- -. <br />a� <br />�w <br />�z <br />=5 <br />J <br />o <br />w <br />�0 <br />_�< <br />Lo <br />°< <br />`` <br />>M <br />J <br />O� <br />rn <br />m <br />m <br />W <br />L <br />00 <br />(0 L0 <br />r <br />N <br />CL <br />L0Q <br />6 -6 <br />N <br />-°oJ <br />T <br />C° <br />+-+ <br />Lid <br />O <br />LL <br />Itt <br />0 <br />L <br />CIO <br />I� <br />tB N <br />m <br />O <br />O <br />Q <br />00 N <br />r <br />MM <br />(0 LO <br />o <br />Z <br />c�6 <br />z <br />E 00 <br />E r <br />iri <br />CU <br />a <br />U <br />Q p <br />� <br />JOB <br />NO : <br />23-04905 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S N 1 <br />