Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />3/8" CEMENT <br />PLASTER - <br />12 MIL DRYLOK <br />CMU - MASONRY BLOCK <br />EXTREME <br />WINDOW <br />FASTENER <br />1) SEALANT AT <br />4 SEALANT JOINT <br />WINDOW BUCK TO <br />OUTSIDE EDGE OF <br />'' MASONRY <br />WINDOW BUCK <br />, 2) SEALANT JOINT <br />5) SEALANT FROM <br />INSIDE EDGE OF <br />WINDOW FRAME <br />WINDOW BUCK <br />ACROSS WINDOW BUCK <br />AND EXTEND TO <br />WINDOW FRAME <br />MASONRY <br />ATTACHED <br />6) TOOLED SEALANT <br />r} -= REQUIREMENTS <br />BEAD BRIDGING <br />CLADDING AND WINDOW <br />FRAME <br />3) SEALANT WINDOW FRAME T( <br />WINDOW BUCK ALL THE WAY <br />AROUND, INCLUDING SILL. <br />SCS 06_05 CMU INSTALLATION 6 POINT BUCK AND <br />FENESTRATION INSTALLATION AND INTERFACE <br />JAMB, SILL AND HEAD DETAIL <br />APPROVED SHEATHING <br />APPROVED HOUSEWRAP <br />STRUCTALATH TWIN TRACK 2.5 <br />3/4" CEMENT PLASTER <br />12 MIL (min) DRYLOK EXTREME <br />APPROVED FLASHING TAPE <br />'V' SEALANT SOCKET WITH <br />TOOLED APPROVED SEALANT <br />SCS 06_02 WINDOW FIN INTERFACE WITH <br />EXTRUDED SHOULDER <br />WEATHER <br />RESISITIVE <br />BARRIER <br />TAPE <br />(ASSEMBLED WINDOW )WIN•�OW )) <br />HEAD FLASHING TIE-IN INSTRUXTIC <br />1. Cut, fold up & temporarily secure <br />resistive barrier above header to allow for <br />flashing installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />s <br />DO NO' <br />BOTTO <br />FLANGE <br />^' ^ 1D WEATHER <br />✓E BARRIER & <br />tARILY SECURE <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />WATER RESISTIVE BARRIERS ARE REQUIRED BEHIND STUCCO <br />PER THE FBC RESIDENTIAL 7TH EDITION (2020) <br />Detail Instructions <br />Refer to the number marked as oRstructions in each detail that corresponds to the <br />numbered items in the list below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />11 ��[-loll\l J <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD BED <br />VINYL SHOWER PAN <br />SLOPE <br />d ° ° ^ <br /><7 <br />WOOD FRAME CONSTR. <br />EXTERIOR SELF -ADHERED FLASHIN <br />SHEATHING BY LAPPING DOWN -� <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOI: <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />1 <br />4 <br />4SHING <br />WEATHER RESISTIVE <br />BARRIER <br />S'S <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL WP02) <br />SELF -ADHERED FLASHING v <br />1 � <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />(SEE DETAIL WP07) <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />E <br />4M <br />SELF-ADHEF <br />(D <br />1'4" PER PLAN <br />V-0" PER PLAN <br />SHOWER SEAT <br />J <br />a z <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Q <br />W <br />n <br />co <br />Q <br />z <br />Z Z <br />a' CL <br />Ix <br />a, a- <br />= W <br />U <br />LU W <br />_ Cr <br />W <br />o <br />to <br />DOOR ROUGH OPENING <br />- 3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND <br />RETURN UP JAMB 6". USE LIQUID <br />NAIL BRAND OR EQUAL WEATHER <br />PROOF CAULKING <br />SELF -ADHERED FLASHING <br />SUBFLOOR <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />8 2 <br />:LF-ADHERED FLASHING <br />TCH <br />HERED FLASHING <br />2 <br />I4 <br />5 <br />1 <br />I <br />I <br />I <br />I <br />PLASTER STOP <br />CONTINUOUS BACKER <br />ROD & SEALANT <br />A <br />WINDOW UNIT <br />FLASHING REQUIREMENTS <br />- SLOPE <br />0.3 in: 12.0 in <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall <br />(0.6 cm: 30.5 cm) <br />include flashing as described in Section R703.4. <br />SELF -ADHERED FLASHING <br />EXTERIOR <br />R703.1.1 Water resistance. The exterior wall envelope shall be designed and constructed in a manner that prevents the accumulation of <br />CEMT. FIN. <br />water within the wall assembly by providing a water-resistant barrier behind the exterior cladding as required by Section R703.2 and a means <br />BUILDING PAPER <br />of draining to the exterior water that penetrates the exterior cladding. <br />WIRE LATH <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls No. 15 asphalt felt shall be applied <br />horizontally, with the upper layer lapped over the lower layer not less than 2 inches. Where joints occur, felt shall be lapped not less than 6 <br />inches. Other approved materials shall be installed in accordance with the water -resistive barrier manufacturer's installation instructions. The <br />No. 15 asphalt felt or other approved water -resistive barrier material shall be continuous to the top of walls and terminated at penetrations and <br />building appendages in a manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over <br />wood -based sheathing, shall include a water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade <br />O <br />D paper. The individual layers shall be installed independently such that each layer provides a separate continuous plane and any flashing <br />(installed in accordance with Section R703.4) intended to drain to the water -resistive barrier is directed between the layers. <br />SELF -ADHERED FLASHING <br />1 <br />CEMT. FINISH SILU POTSHELF/ CHIMNEY SHOULDER <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance <br />equal to or greater than that of 60-minute Grade D paper and is separated from the stucco by an intervening, <br />MECHANICALLY FASTEN IF RUBBERIZED ASPHALT <br />substantially nonwater-absorbing layer or designed drainage space. <br />NEEDED IN CORNERS RUBBERIZED ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />R703.4 Flashing,Approved metal flashing, vinyl flashing, self -adhered membranes and mechanical) attached flexibleflash <br />ing asn <br />pp g� y gllfdhyg shall be <br />FLASHING <br />SELF -ADHERED FLASHING <br />applied shingle -fashion or in accordance with the manufacturers instructions. Metal flashing shall be corrosion resistant. Fluid -applied <br />membranes used as flashing shall be applied in accordance with the manufacturer's instructions. All flashing shall be applied in a manner to <br />SCORED <br />prevent the entry of water into the wall cavity or penetration of water to the building structural framing components. <br />RELEASE PAPER <br />Self -adhered membranes used as flashing shall comply with AAMA 711. All exterior fenestration products shall be sealed at the juncture with <br />R(BEFORE FOLDING, SCORE ELEASE PAPER TO EXPOSE <br />the building wall with a sealant complying with AAMA 800 or ASTM C920 Class 25 Grade NS or greater for proper joint expansion and <br />ADHESIVE ASSHOWN) <br />contraction, ASTMC1281, AAMA 812, or other approved standard as appropriate for the type of sealant. Fluid -applied membranes used as <br />flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved flashings <br />shall be installed at the following locations: <br />1.1.Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall <br />finish or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings <br />shall comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />2 <br />following: <br />5 <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />4 <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />6 <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for <br />7 <br />subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />1.2 1.2. In accordance with the flashing design or method of a registered design professional. <br />SELF -ADHERED FLASHING �' <br />1.3 1.3. In accordance with other approved methods. <br />INSIDE CORNER L11 <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMAANDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />2.2.At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under <br />stucco copings. <br />Ground <br />3.3.Under and at the ends of masonry, wood or metal copings and sills. <br />4.4.Continuously above all projecting wood trim. <br />5.5.Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6.6.At wall and roof intersections. <br />Water Resistant Barrier <br />7.7.At built-in putters. <br />FOUNDATION WEEP SCREED <br />f-STRIP OF SAF <br />1-DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) o- <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) - - <br />BOND BREAK WEATHER RESISTANT BARRIER- - - - <br />SELF FURRING (SF) LATH -• w - <br />PLASTER ACCESSORY - - <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS :LL1\S\`1 <br />I <br />it 1 <br />1I 1 <br />p 1 <br />11 <br />- ail I <br />ACKER ROD J <br />FINISH <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />- 7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />- Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />-7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />N <br />N <br />c <br />0 <br />r <br />W <br />o <br />7ui2: <br />r�= <br />, D co >< <br />r �w G- <br />VI 1p p <br />N ! V L <br />�y o co <br />N <br />C <br />N O i Q <br />d u 0 <br />N n 'aT <br />.= <br />E <br />o <br />0 13 <br />N <br />0 <br />fV <br />O <br />t[� <br />o <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />a <br />� <br />Q <br />E <br />o �8 <br />1 <br />N O1 0o <br />4) C N <br />m <br />nNO <br />a) m v M LL <br />Q <br />C -JLL LL W <br />�LLa <br />Z <br />- o a <br />L l0 � <br />tpg <br />W <br />p <br />5 rem 0 <br />���� <br />Z <br />LLW <br />m d <br />°�,° M Z J <br />JK <br />N <br />o cdi 0 N <br />Z <br />W <br />❑ ❑ <br />0 <br />� <br />z � <br />z <br />z <br />Q � <br />N <br />CD <br />CD <br />0 <br />�- <br />u- <br />5 <br />LL <br />4-1 <br />rp <br />w <br />a <br />W, U <br />-� <br />O <br />N <br />YZN <br />'01- <br />L <br />� <br />0 <br />� <br />w <br />= <br />M <br />LJL <br />z O <br />E <br />aE0 <br />LJ <br />� z <br />Zo <br />❑ a <br />l'- rt7 <br />p <br />.0 <br />V ¢ <br />U O <br />U <br />¢ <br />Z <br />1D <br />� <br />� <br />4 U <br />4 <br />f0f <br />a <br />U1 <br />� <br />Z10 <br />. <br />Z <br />� .I <br />s <br />¢ b <br />S Z <br />>a0 <br />J <br />W <br />?- <br />O� <br />a <br />a <br />N W <br />1 <br />31 <br />v <br />°I< <br />In <br />> Ln <br />J <br />O <br />rn <br />TO <br />M LOT <br />CV <br />a <br />N <br />Q <br />$ <br />0.. <br />U) <br />N <br />*-0 (0 <br />O <br />Ln <br />lie <br />M <br />L) M <br />C:) <br />°N° N <br />it) <br />T <br />Q <br />T <br />E <br />.0 Ln <br />^ <br />cn Ln <br />Z <br />Mn <br />Z <br />E T <br />Vt <br />a��i <br />` <br />c <br />M <br />v � <br />¢ o <br />JOB <br />NO : <br />23-04903 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />WP1 <br />