6712 Back Forty Loop
Zephyrhills
>
Building Department
>
Building Plans
>
6712 Back Forty Loop
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 1:52:15 PM
Creation date
2/27/2025 11:25:45 AM
Metadata
Fields
Template:
Building Plans
Street #
6712
Location
Back Forty Loop
Contractor
Lennar Homes
Building Plans - Permit #
6317
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with LIL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in LIL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI LIL 2034, standard for single and multiple station CO alarms or <br />LIL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would Include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.WEATHERPROOF DUPLEX OUTLET <br />P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />I� SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 THREE-WAY SWITCH <br />24 FOUR-WAY SWITCH <br />jR RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® HI -HAT -TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />® RECESSED LIGHT FIXTURE <br />4-P.C. LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />16) EXHAUST FAN <br />Q EXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />�BP PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />©2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />1]M ELECTRIC METER <br />WWI ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />C. J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />Y J OPT. CEILING FAN <br />W (1) PHONE LINE, (1) DATA PORT <br />150A/200A <br />INDOOR <br />PANEL <br />CENTER <br />#14 to lights & outlets <br />NEMA 1 #12 to appliances and GFI <br />150 AMP/ <br />200 AMP #10 to WH <br />#& to Range <br />10 #& t0 H VAC <br />_LT <br />R <br />150=2/0 <br />200=470 in 2" Conduit <br />200 amp <br />150 amp <br />UNDERGROUND i nn ct <br />SERVICE BY POWER CO. <br />INTERSYSTEM 4 Bare Cu Ground <br />BONDING #4 GROUNDING WIRE <br />TERMINATION PER WITH CODE APPROVE <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />---- <br />LANAI----L1 <br />I <br />/� > I <br />I <br />�\ <br />I <br />V <br />I <br />GFI <br />I <br />c - <br />SRKFST. <br />LIGHT AS_PER <br />SPECS <br />rI 5- " <br />GF <br />EX <br />I I <br />GFIG <br />FI _ <br />• II <br />I <br />I <br />- - I: o IIGF <br />I ` � I I <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS- <br />AC PAD <br />WP <br />GFI DISC. <br />DINING <br />LO <br />LIGHT AS PER <br />SPECS <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN <br />SCALE: %4'=1'-0" <br />0 <br />• <br />PENDANT <br />LIGHT PER <br />SPECS <br />GREAT RM <br />ROUGH -IN <br />U.C.OUTLET <br />FOR OPT. <br />FAN/LIGHT <br />SWITCH FOR <br />1 OPT. CLG. FAN/ <br />I <br />DISPOSAL <br />LIGHT PRE -WIRE <br />a � <br />CH <br />U,•� <br />X4 <br />�.:��, <br />- GFI # , , • r. <br />,w <br />Q / <br />v <br />— <br />GARAGE <br />LIGHT AS <br />v PER SPECS � <br />W / <br />� W <br />,.,GARAG E <br />GARAGE--&/ <br />DOOR <br />GFI <br />--------- --- <br />I I I <br />IRRIGATION GFI I I <br />a <br />I @ 44" A.F.F. j <br />I 1 I <br />• <br />I I <br />I <br />I � I <br />-----------------------------� <br />COACH LIGHTS <br />OR PREWIRE AS <br />PER SPECS <br />II �' GFI <br />ENTRY <br />--------------------� <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I � <br />I <br />I I <br />I I <br />I� �I <br />I ALT I <br />j I AC PAD I j VP <br />_ of a <br />7 <br />OWNER'S <br />WP ===� <br />SUITE <br />:��_OPT. O. 'BAT'H�`` <br />.� <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />�------ WIC �\ � <br />I I <br />RECEPT. FOR (':-- 1 <br />ALARM SYSTEM <br />LL <br />S.D. <br />0 <br />/ OPT. CLG. FAN/ <br />�- LIGHT PRE -WIRE <br />BSA 2 <br />PROVIDE PHONE / CABLE I <br />AND OUTLET AT TECH BEDROOM 4 <br />CENTER S.D. <br />/ /---------- <br />3 4 ~ I <br />0 iLc <br />HAU W <br />GFI @ I--------- <br />44" A.F.F. I \ H A\Ff <br />Ind W <br />S.D. <br />I � <br />I <br />OPT. CLG. FAN I <br />LIGHT PRE -WIRE <br />BEDROOM 3 <br />I1 <br />I OPT. CLG. FAN/ <br />LIGHT PRE -WARE <br />BEDROOM 2 <br />I � <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />1.5" VTR 3" VTR_ ij1_ <br />III I <br />�I I <br />I I <br />I I <br />I I <br />I r� <br />3" VTR III <br />I � I <br />I I I I I <br />I I 1 7n I t <br />R <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN <br />SCALE: %4'=V-0" <br />!r! <br />N <br />N <br />a <br />a <br />C lC V N <br />►+ Q_ <br />y !9 O <br />W d O J <br />a-r <br />m c <br />L <br />3 � <br />N) G <br />= I; <br />4o O <br />d to <br />M <br />O <br />fV <br />LO <br />r-- <br />-_ <br />= F' <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />a <br />N <br />$ R 8 <br />N 8 N r <br />to Co <br />c. <br />LL a <br />rncoi <br />dyl <br />a <br />r a <br />M tL <br />Z <br />OI <br />a8 0 o <br />n <br />o ` `" d <br />O) <br />W <br />Z <br />LLM <br />LLW <br />05 Qj Z <br />2 Z 8 3: <br />N O U ❑❑❑ <br />W <br />z <br />z <br />L_ <br />�Q) <br />cn, <br />U <br />`�. I <br />0 <br />w <br />N <br />Iz <br />ice— rh' <br />c <br />q <br />M <br />w <br />J <br />E <br />q <br />0 <br />aP <br />> <br />z® <br />a� <br />too <br />Z <br />¢04 <br />p0.4 <br />a <br />Wly <br />d <br />ro <br />Vi ` <br />W p <br />b <br />< p <br />.0 <br />� <br />x <br />Z <br />A <br />�LL <br />�r <br />M <br />if <br />O 4 <br />V <br />°O <br />= <br />�U-) <br />J <br />0 <br />v, <br />i <br />Ln <br />(� Ln <br />r <br />CV <br />$ <br />N <br />J <br />(n o <br />N <br />Lin <br />oILL <br />co N <br />O <br />m N <br />L0 <br />r <br />< <br />r l5 <br />T� <br />LO <br />CEO CV <br />LO <br />0 <br />Z <br />Z <br />E T <br />to <br />d <br />J <br />Q <br />J <br />JOB <br />NO: <br />23-04903 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3 <br />