Laserfiche WebLink
THIS DETAIL ONLY REFERS TO THE DIAMOND -MESH <br />EXPANDED METAL LATH ATTACHMENT. <br />METAL LATH <br />WALL SHEATHING <br />'''' v <br />.................. I' . ..'.'.'.'.'.'.'.'.'.'.'..'. <br />::� ::::::::::::::: Imo:::::::::: <br />16GAx1-1\2" LONG 3/4"-1" CROWN 8':': 1: <br />( ) t5kMAX . . <br />I. :::... 16GAx1-1/2" LONG (3/4"-1" <br />STAPLES @ 6" O.C. VERT BETWEEN <br />STUDS (NOTED THUS:—) - OFFSET CROWN) STAPLES @ 6" <br />STAPLES BETWEEN STUDS AS SHOWN O.C. VERT INTO STUDS <br />(NOTED THUS:—) <br />METAL LATH ATTACHMENT DETAIL <br />REV. 09.24.21 SCALE: 3/4" = V-0" <br />*DETAIL EXCEEDS THE REQUIREMENTS FOR FBCR 703.7.1 LATH* <br />**ONLY APPLIES TO LENNAR TPA/JAX** <br />CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O 0 0 <br />5'-0" ¢ - <br />c <br />STUB -OUT FOR 1'-O„ O o CD <br />GAS METER 0 ° <br />� U <br />O F <br />N <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />**ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY** <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" 0, C. <br />16-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C, <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />1314" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" orp <br />5000s 1.8/1.7 <br />nel <br />wood panels <br />Two 3/4" wood panels or 2 x <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.811.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602,0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking ° <br />1/8" gap <br />r / <br />FILL CELL <br />STD. 90° HOOK BOND BEAM <br />U) <br />w <br />STD. 90° <br />CONT. #5 <br />CONT. #5 HOOK <br />BAR <br />BAR <br />#5 CONT. <br />FROM <br />ON <br />TOUHI HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />SEE PLAN FOR REQ'D <br />PLYWOOD FLOOR <br />COLUMN AND <br />SHEATHING PER PLAN <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts from <br />STUDS <br />above to bearing below. <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. <br />}Small 2" min. <br />2" max <br />gap <br />• A <br />4 max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. 2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4 <br />required when Indicated or max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite -Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVINGy" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />DOUBLE JOIST CONNECTION top flange uthcutst. <br />Birdsmouth cuts. N.T.S. <br />Under 2nd floor cnh rmn w/ 1—ric <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* Non -stacking walls <br />over squash=20 blocks and <br />require additional <br />wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate <br />details in <br />One 10d box <br />areas=20 of high <br />or=20 sinker <br />lateral load. <br />nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES —� <br />DO NOT cut, notch <br />or drill flanges <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Load bearing walls <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls : for vertical load transfer <br />when load bearing - for lateral support when joists <br />le <br />meet over wall, or wall stacks directly over wall or <br />Web Stiffener Fastener Schedule <br />Joist Bearin Location <br />Series Depth End Intermediate <br />BCI5000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5- d <br />BCI 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14 <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-718" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/ " <br />8 <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />1 6-16d <br />SIMPSC <br />w/ (22) <br />NAILS T <br />5/81 <br />THRU <br />BOLT <br />SIMPSC <br />w/ (22) <br />NAILS T <br />R TRUSS <br />OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />AIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON META12 / <br />Plumbing META12 TSS INSTALLATION <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Joist <br />�When joists meet over wall, provide <br />1 3/4" minimum bearing for each. I -Joist can be offset <br />Q " Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />10dnails require additional consideration. <br />SECTION @INT. BRIG. WALL— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />IDDIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />FA <br />6" A 1y2" ROUND HOLE MAY 6" 6" DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1Yz" <br />THE WEB, PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS, <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1y2" <br />Any 16}o_tst.._.__ <br />1'-0" <br />TA, <br />1,-2, <br />1,7-2". <br />1'_3a <br />T-W <br />2-4" <br />2-11" <br />3L7' <br />41 f <br />4 0 <br />9-4' <br />_ ..12 <br />S ia6f MY-__ _ _ ._. <br />10 <br />1" <br />11,. <br />1,_2. <br />1" Z' <br />1-7" <br />2 " <br />3'-2" <br />3'-10" <br />"' <br />617", <br />" <br />7 ' <br />20 <br />1'-W <br />V-1"" <br />1" 2' <br />1'-2" <br />24)" <br />3-0" <br />4'-0'" <br />4'-10'" <br />9-11" <br />6-11'" <br />7'-11', <br />8l-1.11t <br />24 <br />1'-0'" <br />V-1" <br />1' Z' <br />1'-3 <br />2f <br />3'-T' <br />4'-9" <br />6-19' <br />T 2" <br />8'4" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y2" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3 to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />. <br />$ i <br />Main <br />:1 ,I <br />Backer block (12" wide min.) =r1 I ICI I II I II I II I I� III= -1 i I <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM <br />SEE PLAN FOR °• ° • • <br />4 a <br />FOUNDATION INFO a <br />STEM FOUNDATION <br />Nail with I — GRADE �—REINF, SEE PLAN <br />\ Filler block. <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />AV1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />depth <br />o � P <br />I -JOISTS BUCKETS <br />N.T.S. <br />Jc <br />tvi- t,nHar 4 rvu <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON META12 / META12 TSS <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />`�® <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A <br />(WHEN <br />w/ (18)10d x 1 1/2" <br />° <br />REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'4' v <br />CENTERED @ PIPE <br />PENETRATION <br />I ° <br />a ° <br />I, 111—III—I1 n a <br />ICI � Imo_. <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />° <br />y-- SEE FND. PLN. <br />SIZE & REINF. <br />BELOW <br />GRADE PIPE VERTICAL THRU FND. <br />G <br />TOP (2) #5's x 4'-0" <br />CENTERED @ PIPE <br />PENETRATION <br />—\ <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />is • ° • <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENTERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4a ' .G q . <br />°' <br />d <br />=11 M1 I M1 I Q I 1=! 11 <br />-I I iEd 15d ° ° d 1I 111111 � <br />SEE FND. PLN. <br />SIZE & REINF. <br />C <br />cat <br />c*�a <br />C" <br />cue <br />C= <br />a �- <br />>UJ <br />IL :5 cm <br />v =C­= <br />474 <br />- CM >< <br />�® <br />y -a C14 s <br />si. s cu <br />as - _ <br />ECJ <br />t� <br />3 cu <br />� CU <br />E <br />a � <br />co <br />_ <br />M <br />N <br />0 <br />N <br />00 <br />"• <br />No <br />"78 7r <br />m <br />� <br />STATE OF <br />?• <br />� <br />'0' �• �' s•"•'k� <br />4 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 <br />Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />E "9 N <br />O M S 0 <br />ci <br />w C5 QC�J: L <br />G <br />500 N LJL <br />L w <br />W <br />Q <br />M CDa <br />JU wa a 0 <br />0 <br />0 Z <br />z <br />-.0N <br />L may° <br />> 0 <br />a <br />W <br />0 <br />(ONO m Q <br />0 n rn ¢ z <br />Z <br />co <br />w <br />N t7 Z U O <br />0 <br />F=- <br />zun <br />o� ❑❑❑ <br />to <br />(D <br />m 12 <br />- <br />z N M <br />o <br />z N <br />(D <br />z o � <br />J <br />U*) <br />N <br />c`� <br />z <br />U = <br />Q)(1 <br />0 <br />+/-�J <br />" V <br />C <br />W <br />a ° <br />J <br />0 <br />Ln <br />� <br />� <br />w °o <br />- N <br />::3 <br />n$ <br />U <br />„, <br />r— J EIBM <br />= w <br />U i N <br />c `n d <br />¢ o <br />° <br />N O <br />41111 <br />o <br />w <br />CO <br />M <br />M <br />J <br />z ¢ <br />O <br />Z <br />O <br />C',V <br />w� <br />0e <br />oa <br />F <br />— o E <br />g <br />? U <br />n °� <br />z <br />10 <br />z <br />�w <br />C <br />is <br />¢0 <br />U <br />mo <br />Z <br />m J <br />� <br />¢w <br />�m <br />op <br />�Z <br />go <br />co <br />C) <br />m <br />�o <br />a <br />N W <br />�k <br />Z3 <br />oZ, <br />_ <br />o <br />w� <br />>� <br />.J <br />M <br />V' <br />0I¢T0U <br />a F <br />0 <br />C 0 <br />2 <br />>M <br />rn <br />m <br />2 <br />O <br />CID00 <br />0LO <br />0.111%N <br />Q <br />J <br />N <br />° <br />>, <br />N <br />0 <br />Ln <br />O <br />U_ <br />m cv <br />O <br />O <br />Q <br />co <br />r <br />CO CV)o <br />' <br />co <br />z <br />E O <br />i <br />;v <br />c <br />a <br />E= <br />U 0 <br />JOB <br />NO : <br />23-02469 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />