My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6766 Back Forty Loop
Zephyrhills
>
Building Department
>
Building Plans
>
6766 Back Forty Loop
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:42:49 PM
Creation date
2/27/2025 11:25:59 AM
Metadata
Fields
Template:
Building Plans
Street #
6766
Location
Back Forty Loop
Contractor
Lennar Homes
Building Plans - Permit #
6037
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />150AI200A INDOOR <br />PANEL CENTER <br />MO <br />200 amp <br />150 amp <br />UNDERGROUND IDis <br />SERVICE BY POWER CO.----_ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 17, 250.94 <br />NEMA 1 <br />150 AMP/ <br />200 AMP <br />#14 to lights & outlets <br />#12 to appliances and GFI <br />#10 to W H <br />#8 to Range <br />#6 t0 HVAC <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram REV.03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16" AFF (general). CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2" AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance with FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />0 <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />;Q) <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />DB <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TELEVISION (OPTIONAL) <br />❑N 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />M <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />r J <br />OPT. CEILING FAN <br />G� <br />(1) PHONE LINE, (1) DATA PORT <br />1.5" VTR <br />I <br />I <br />_III 3" VTR <br />I ' � <br />� T, I <br /><� I I <br />��I I <br />SWITCH <br />q" VTR <br />PLUMBING RISER <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />I C <br />DEDICATED <br />RECEPTACLE FOR <br />ICROWAVE RANGE <br />HOOD PER SPECS <br />WP A/C PAD <br />GFI DISC. <br />h <br />/ I <br />/ I <br />11ENTR wP <br />DB & GFI TO I GFI <br />BE ALIGNED — — — — — — — <br />VERTICALL <br />1 <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS <br />IY M <br />w w <br />W� <br />Z J <br />0 m <br />HUH <br />y0� <br />COACH LIGHTS \ COACH LIGHTS <br />OR PREWIRE AS OR PREWIRE AS <br />PER SPECS , PER SPECS <br />SPEC 3 & 4 KITCHEN FIRST FLOOR ELECTRICAL PLAN - ELEV-A <br />SCALE: %4'=1'-0" <br />ELECTRICAL SPECIFICATION NOTES: <br />ELECTRICAL CONTRACTOR MUST VERIFY <br />WITH THE SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT FIXTURES <br />SHOWN ARE FOR LOCATION PURPOSES. <br />I I I <br />I I I <br />I I I <br />I I I <br />I I I <br />L----------- I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I t <br />I I <br />I I <br />I I <br />I I <br />L--------------------------------------- <br />SECOND FLOOR ELECTRICAL PLAN <br />ELEV-A <br />® o <br />cat . _ <br />-o <br />w <br />C� > w <br />c <br />C*4 ti <br />cu c.a <br />C LL <br />C[ <br />w CL w <br />E <br />m <br />� coo <br />� • •— t1 as <br />4, C5 <br />a <br />f.-.� <br />M <br />O <br />fV <br />����a93Sa39�t6tr Mo <br />.• GEIliSA <br />�,��� <br />ce° f <br />i Sri o I 87':) r <br />.. - <br />., •. �� <br />fib. 3 / r '••' �,�� <br />Psi <br />%`#K3u' etl'a3�a <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />H <br />W E N <br />Q O N N <br />N <br />V 6 <br />O � y it- LL <br />Q C j d Y U <br />LL <br />JlL <br />� Z <br />Z Low o o <br />C> <br />Y <br />W �g rn"m . <br />� <br />z <br />w <br />Z N m Z O <br />U f=- <br />00 ❑❑❑ <br />ZILL <br />Z <br />W <br />Z N M <br />0 00 <br />z <br />z o <br />J <br />z <br />�— <br />w <br />Ou., g <br />N <br />N' <br />w` <br />^ <br />v <br />r— J E <br />ml <br />v o <br />c `n iu <br />¢ <br />f" <br />m <br />o <br />zi <br />w <br />M <br />ch <br />w � <br />o <br />Z <br />i <br />zo <br />20 <br />Z6 <br />Z® <br />:= o <br />CJ <br />z <br />oa <br />F— (6 <br />0 O <br />�0. <br />p <br />r <br />0 Q <br />tt <br />SO <br />i <br />w= <br />o <br />wz ¢, <br />ci M <br /><z <br />p¢Z, <br />mo <br />Z <br />m J <br />U <br />O m <br />Q W <br />0 <br />A <br />¢� <br />0M <br />o� <br />Zz <br />z <br />ao <br />W <br />3 <br />N� <br />M <br />0 <br />c O <br />> co <br />rn <br />0 <br />00 <br />co to <br />iO <br />C11 <br />LO <br />�-. <br />J <br />CV <br />o <br />CL <br />U) <br />+-� o <br />L0 <br />IL <br />co N <br />m <br />d) <br />O <br />LO <br />04 <br />Q 0 <br />E <br />CO cj <br />00 �; <br />o <br />Z <br />Z <br />E CID <br />O <br />U <br />a <br />_j ¢ p <br />JOB <br />NO: 23-02469 <br />SCALE : AS NOTED <br />SHEET NO. <br />3 <br />