ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to center line of the box to be: 16"AFF (general). <br />In a Flood Zone, all electrical equipment to be at or above DFE. <br />Kitchen 44" AFF <br />Bathroom 39" AFF <br />Laundry Room 36" AFF <br />Exterior Waterproof 12" AFF <br />Garage - general purpose 44" AFF <br />Range 2"AFF <br />2. All trim plates and devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the National <br />Electric Codes (NEC 2017), by a licensed electrical contractor who shall be responsible for the installation & <br />sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the branch <br />circuits in all dwelling units per NFPA 70-17, National Electrical Codes (NEC 2017) and as defined in UL 1699. <br />7. Provide Tamper Resistant Receptacles as required by the NFPA 70-17, National Electrical Codes (NEC <br />2017). <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling units in <br />accordance With FBC R315 and NFPA 70-17, National Electrical Codes (NEC 2017). Such devices shall be <br />listed by the appropriate standard, either ANSI/UL 2034, standard for single and multiple station CO alarms or <br />UL 2075, gas and vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and labeled by a <br />Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors. <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and shall be <br />equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffit is not <br />acceptable. <br />13. Chapter 45 Private Swimming Pools - Outdoor swimming pools shall be provided with a barrier Complying <br />with R4501.17.1.1 through R4501.17.1.14. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed within 6' of <br />the outside edge of a sink. This would include the receptacle installed for a washing machine. Receptacle <br />outlets shall not be required on a wall directly behind a range or sink to fulfill the requirement of an outlet <br />every 24". The width of the sink or range is not to be included in the spacing of the outlets unless the distance <br />from the sink or range is greater than 12" for straight counter tops and 18" for sinks and ranges installed in <br />corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FtF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />POF <br />HALF -SWITCHED DUPLEX OUTLET <br />I� <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />� 4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />® <br />HI -HAT - TO BE SURFACE MOUNTED ON J-BOX <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />�D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />I e USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />L J <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />150AI200A INDOOR <br />PANEL CENTER <br />#14 to lights & outlets <br />NEMA 1 b #12 to appliances and GFI <br />150 AMP/ <br />200 AMP b #10 to WH <br />1111 #8 to Range <br />01 #6 to HVAC <br />7 <br />200 amp <br />150 amp <br />UNDERGROUND las <br />SERVICE BY POWER CO. --- <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />200=4/0 in 2" Conduit <br />4 Bare Cu Ground <br />NEC 17, 250.94 CLAMP PER 250.50 AND <br />250.52 OF THE 2017 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram REV. 03.09.22 <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70-2017, NATIONAL ELECTRICAL CODES (NEC 2017) LOCAL <br />CODES AND THE LOCAL POWER/UTILITY COMPANY. <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />DEDICATED <br />RECEPTACLE FOR <br />MICROWAVE RANGE <br />HOOD PER SPECS— <br />U.C. OUTLET <br />SWITCH FOR <br />DISPOSAL <br />SPEC 3 & 4 KITCHEN <br />SCALE: Y4'=1'-0" <br />LANAT---- <br />I A A I <br />I \ /j> I <br />I '07 I AC PAD <br />WP <br />WP `�\�'� I GFI DISC. <br />GFI I <br />I p� <br />�. <br />- - I <br />BRKFST• DINING <br />LIGHT AS PER ` <br />/ SPECS 5'-0" <br />- - - LIGHT AS PER <br />SPECS • <br />4 _ - <br />PENDANT <br />/ GF LIGHT PER <br />�11 SPECS <br />GREAT RM <br />• ��I I <br />GFI I o GFIII �% <br />U.C. OUTLET ROUGH -IN f <br />El <br />FOR OPT. <br />I o I IGF I G FAN/LIGHT <br />- , I I SWITCH FOR 1 OPT. CLG. FAN/ <br />_ GFIi DISPOSAL / `LIGHT PRE -WIRE <br />- <br />- <br />Cl) ` \ <br />_ I LU _ 'GFRPM/I <br />I I \ <br />1'-i0" I I / <br />� <br />I I 3 / <br />1 <br />_Af E-11 <br />T L S <br />1 1 1 S 1 1 HI N I I I I I w -- <br />Df� I I I I , I I / <br />I I I I I I I I I II I I <br />- ,DIV 4F GFI @ 44" -FLYER <br />- W.H. / ' A.F.F. - <br />I <br />� J IZ LU y <br />o_z <br />0 - GARAGE <br />t}i \ LIGHT AS WP I <br />WP IX LU PER SPECS GFI <br />GFI . > w / - � I <br />,,GARAGE 1 <br />GARAGE / v <br />GFI I ENTRY <br />-------------------- --- I <br />IRRIGATION GFI ' I-------- <br />@44"A.F.F.-------- <br />- I 1 I <br />- <br />I I <br />I � I <br />--------------- <br />------------------------------,Z <br />COACH LIGHTS <br />\ OR PREWIRE AS / <br />\ ` _ PER SPECS <br />I( �I <br />II ALT II <br />j I AC PAD I j <br />I� �I <br />RECEPT. FOR <br />ALARM SYSTEM <br />PROVIDE PHONE / CABLE <br />AND OUTLET AT TECH <br />CENTER --- <br />F--------------------I <br />I I <br />I 1 <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I � <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />L------------------------------------ J <br />" <br />VTR 3" VTR <br />lll� ­Ij1, <br />I <br />�I I <br />I I <br />I I <br />I I <br />I r� <br />3" VTR III, <br />I � I <br />I I <br />� I <br />I I I I I <br />3" <br />PLUMBING RISER_ <br />SCALE: NTS NOTE: PLUMBING RISER IS SCHEMATIC TO <br />BE VERIFIED WITH PLUMBER <br />ELECTRICAL PLAN - ELEV - A <br />SCALE: Y4 t=1'-0" <br />:•M7 <br />C% <br />N <br />C" c� v <br />9 W <br />tV o L <br />C lC Ll M N <br />m <br />.� cLLa <br />N O i <br />gn O !V L <br />y o <br />Q 61 N Y <br />== <br />3 as <br />m u <br />a <br />tv <br />m 3 L <br />.°' w m <br />y c� <br />c � <br />m c <br />a � <br />M <br />O <br />N <br />M <br />0 <br />PJo F'E' SJ � a <br />C'. STA`i E F :4y' �Z: <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2020 Florida Building Code - <br />Residential 7th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />M <br />... n W O E N 2 1N <br />m vv <br />ON <br />04 (p <br />y C J <br />g1 <br />° 0 � 4h U- <br />M a. w <br />a. <br />g Z <br />_Z C ccV O 0 <br />1133 <br />0 0 <br />ai 2 in LUI Q <br />Vj W �2�rn d K z <br />Z <br />ti o <br />Z `� M Z to F- <br />IL <br />N O U ❑�❑ <br />Z <br />W <br />04 Q <br />z N S <br />z <br />z o <br />Q <br />J — <br />a <br />M <br />to z <br />11 <br />1J N <br />W � <br />0 a <br />U -� <br />o W <br />$ <br />c <br />LACn <br />W J <br />U o <br />c to <br />N 0 <br />Q <br />S� <br />o <br />M <br />C"> <br />p <br />Z <br />4 <br />o <br />�o <br />>o <br />< <br />21 0 <br />E <br />�� <br />of <br />z® <br />I— ro <br />`<1000 <br />�o <br />�o <br />o E <br />CID <br />�< <br />g� <br />Z <br />ai <br />wo <br />�o <br />�� <br />_ <br />� <br />cn � <br /><om0 <br />�¢ <br />OU <br />w <br />o � <br />ZF <br />Z <br />m J <br />y o <br />¢ Z. <br />ZZ <br />Fm <br />°o <br />g o <br />W <br />a 3 <br /><o <br />Ww <br />m <br />r— <br />VM <br />iI< <br />a <br />� C <br />> Ln <br />J <br />m <br />0 <br />0 <br />CL <br />N <br />^ <br />N 0 <br />v, <br />�7 <br />m <br />+� O <br />Ln <br />..� <br />0 � <br />M <br />U ce) <br />o <br />04 <br />m N <br />Ln <br />r <br />Q <br />r <br />� O <br />m <br />�' y CM <br />o <br />Z <br />Z <br />E O co <br />t° <br />m <br />E v c <br />U <br />� <br />a <br />� Q p <br />JOB <br />NO : 23-02469 <br />SCALE : AS NOTED <br />SHEET N0. <br />3 <br />