Laserfiche WebLink
i • 2 ■ 3 • 4 ■ 5 ■ 6 • 7 ■ 8 ■ 9 ■ 10 ■ 11 ■ 12 ■ 13 ■ 14 ■ 15 ■ 16 ■ 17 ■ 18 ■ 19 ■ 20 <br />R <br />■ <br />P <br />■ <br />0 <br />■ <br />N <br />■ <br />8" REINF. MASONRY 1/2" BITUMINOUS BOARD <br />\\ I H ISOLATION JOINT <br />DOWELS AT VERTICAL WALL <br />REINFORCEMENT WITH 50 CONCRETE SLAB - SEE PLAN <br />BAR DIA LAP SPLICE T.O. SLAB <br />ELEV = SEE PLAN <br />77- <br />GRADE -SEE CIVIL <br />VAPOR BARRIER - SEE ARCH <br />DRAWINGS <br />GROUT SOLID <br />BELOW GRADE <br />T.O. FOOTING <br />ELEV = SEE PLAN <br />_ SEE FOUNDATION PLAN <br />AND/OR FOOTING SCHEDULE <br />FOR FOOTING SIZE AND <br />REINFORCING. <br />TYPICAL PERIMETER SECTION <br />3/4" = 1'-0" <br />3/4" = 1'-0" <br />.L T.O. SOIL <br />EL.= SEE CI% <br />ACI STD 90 <br />DEG. HOOK <br />3" <br />CONT #4 ALONG EDGE <br />CONCRETE SLAB v�i MASONRY WALL BEYOND <br />- SEE PLAN <br />SLOPE DOWN 1/8" CONCRETE SLAB - SEE PLAN <br />PER FT. <br />i <br />T.O. SLAB <br />" ELEV = SEE PLAN <br />^i I i. <br />\- VAPOR BARRIER - SEE ARCH <br />i 1 ' DRAWINGS <br />(2) CONT. COURSES OF <br />MASONRY GROUTED SOLID. <br />T.O. FOOTING <br />ELEV = SEE PLAN <br />SEE FOUNDATION PLAN <br />AND/OR FOOTING <br />SCHEDULE FOR FOOTING <br />SIZE AND REINFORCING. <br />2 TYPICAL DOORWAY SECTION <br />s602 3/4" = 1'-0" <br />3/4" = 1'-0" <br />,LT.O. SOIL <br />EL.= SEE CI\j <br />ACI STD 90 <br />DEG. HOOK <br />3" <br />SEE SCHEDULE FOR ALTERNATING <br />TOP TRANSVERS BARS <br />CONCRETE SLAB <br />(2) #4 CONT. - SEE PLAN NOTE <br />- (1) TOP AND (1) BOTTOM CONT. #4 TOP AND BOTTOM <br />ALONG EDGE SUPPORT BLOCKS AT T-0" O.C. <br />U <br />(V <br />o J co <br />_ m <br />3 "0.67 TS" THICKENED SLAB EDGE <br />5602 3/4" = 1'-0" <br />GENERATOR PAD SECTION <br />3/4" = 1'-0" <br />(2) #4 CONT. - (1) TOP AND (1) <br />BOTTOM ALONG EDGE <br />SEE SCHEDULE FOR ALTERNATING TOP <br />TRANSVERS BARS <br />L'I <br />CONCRETE SLAB <br />d <br />_z <br />� I <br />, <br />0 1� it <br />1 SUPPORT BLOCKS AT <br />T-0" O.C. <br />U <br />ih CONT. #4 <br />"1.0 TS" THICKENED SLAB EDGE <br />3/4" = 1'-0" <br />SEE SCHEDULE FOR ALTERNATING <br />ALTERNATE: TOP TRANSVERS BARS <br />#4x4'-6"LG AND # <br />4x3'-0"LG AT 18" O.C. CONCRETE SLAB - SEE <br />PLAN NOTES <br />z <br />SEE FOUNDATION PLAN <br />7 NOTES FOR SLAB <br />U REINFORCEMENT <br />M <br />(4) #4 CONT. <br />(2) TOP AND (2) BOTTOM <br />"1.33 TS" THICKENED SLAB EDGE <br />3/4" = 1'-0" <br />12" MIN <br />TYPICAL FUEL TANK PAD <br />3/4" = 1'-0" <br />N O O O <br />0 <br />T- 6" ih WALL FOOTING <br />- SEE PLAN <br />MAX. <br />EL. = SEE PLAN <br />d b T.O. FTG <br />WALL FOOTING REINF. <br />- SEE SCHEDULE <br />McEtroyEngineering. <br />STRUCTURAL DESIGN GROUP <br />1835 EDGEWATER DRIVE ORLANDO, FL. 32804 <br />PHONE: 407.245.8775 FAX: 407.245.87" <br />WEBSITE: rncdroyeng.com <br />Firm Registration: #33835 <br />ME PROJECT NO: 1621-04 <br />"TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY <br />WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE <br />SAFETY STANDARDS AS DETERMINED BY THE LOCAL AUTHORITY IN <br />ACCORDANCE WITH CHAPTER 5,13.79AND CI€APTER 633." THE DRAWINGS <br />ARE BELIEVED TO BE CORRECT TO THE BEST OF MY KNOWLEDGE. THE <br />ACCURACY OF THE AS -BUILT CONDITIONS CANNOT BE GUARANTEED. <br />SEAL <br />Craig E. McElroy P.E. - FL No. 44741 <br />owIla!/J/// <br />= No. 44741 <br />STATE OF <br />rr=r�0RID�'-'4 �'` <br />F .. <br />loll I <br />tZ�ZzlZl <br />Ad've%ntHealth <br />ZEPHYRHILLS <br />ZEPHYRHILLS GENERATOR ADDITION <br />wrisHunton <br />A R C H I T E C T <br />DATE SUBMISSION NO <br />12.17.21 CONSTRUCTION DOCUMENTS <br />TYP. SECTION AT RETAINING WALL 11 TYP. SECTION AT RETAINING WALL 12 TYPICAL BLOCK OUT AT CONCRETE WALL <br />3/4" = 1'-0" 5602 3/4" = 1'-0" s602 1/2" = 1'-0" <br />FOUNDATION DETAILS <br />PROJ. NO. H-20232.00 SHEET <br />DRAWN VMM <br />S602 <br />1 ■ 2 ■ 3 <br />■ 4 <br />■ 5 ■ 6 ■ 7 ■ z ■ 41 ■ 10 ■ 11 ■ 12 ■ ■ r ■ 15 <br />■ 1� ■ 17 ■ 18 ■ 19 ■ 20 <br />Copyright HuntonBrady Architects P.A. All Rights Reserved. 800 N. Magnolia Ave., Suite 600, Orlando, Florida 32803 (407) 839-0886 (407) 839-1709/Fax www.huntonbrady.com License AAC001744 <br />