My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2939 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2939 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 1:28:14 PM
Creation date
2/19/2025 8:49:00 AM
Metadata
Fields
Template:
Building Plans
Street #
2939
Location
Moulden Hollow Dr
Contractor
Lennar Home
Building Plans - Permit #
20616
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Al [1 IW1IIrI1WliI <br />m <br />Ln <br />18 <br />N <br />C <br />O <br />ER, <br />00 <br />E <br />Go <br />N <br />M <br />P <br />0 <br />v <br />TYP @ 2 STORY <br />J <br />S6 <br />H.B. <br />fta11111111iii <br />(3) 2X4 #2 SPF W/ (3)16d 1 <br />TOENAILS @ BASE 8 <br />o <br />°p <br />in <br />iv <br />COND. COND. <br />J <br />TYP @ 2 STORY <br />FLEX M <br />8'-8" FLAT CLG. <br />CARPET <br />4r_O" r_On <br />_--_-______ <br />--------- <br />H DR AT 7'-4" - - -E IV T R <br />6-0" - " FLAT CIL <br />N <br />FLOOR G.T. <br />FAM I LY ROO M <br />8'-8" FLAT CLG. <br />CARPET `�° <br />0 <br />16'4j" <br />I <br />I <br />I <br />I <br />I <br />I <br />I I <br />I I <br />IG I <br />S3 <br />I I I <br />1 1 7 I$ <br />=," <br />C'' <br />00 <br />I <br />I <br />I <br />I <br />I <br />1 3 <br />I UP 116 <br />1 4 1 5 <br />42" SLOPING <br />HALF WALL <br />2X4 SPF <br />O <br />TOENAILS @ <br />BASE <br />G <br />40S3if <br />9 <br />0 10 <br />11- <br />- <br />- <br />- - <br />12 <br />12 <br />T <br />o <br />fh <br />YL <br />8,_8, <br />N <br />(2) #5'S <br />00 <br />00 <br />ZX0 WALL <br />5-SH <br />12" DEEP <br />2068 B. F <br />I <br />T-8" T-8" <br />00 <br />q <br />- <br />T-6" <br />J <br />S6 <br />TYP @ 2 STORY <br />(3) 2X4 #2 SPF W/ <br />(3)16d TOENAILS @ <br />BASE <br />= t°7 <br />O00 <br />o DINING ROOM <br />PATIO 8'-8CAR ET LG. <br />4'-0" 6-2" 6-6" <br />= <br />d 007 <br />I <br />rn <br />01 p 01 <br />J J J <br />W.H. <br />fq (3) 2X4 #2 SPF W/ <br />(3)16d TOENAILS <br />O @ BASE <br />2'-6,, L BUILDER TO PROVIDE <br />APPLIANCE PROTECTION <br />WHEN REQUIRED PER FBC <br />2 CAR GARAGE <br />8'-8" FLAT CLG. <br />4'-8" 20'-8" <br />FOYER <br />8'-8" FLAT CLG. <br />TILE <br />O I <br />3068 I <br />------- <br />rn <br />(2) #5r S <br />4 <br />v <br />o <br />' <br />CC <br />r----- <br />I D <br />j S3 <br />I <br />I <br />I <br />I <br />I <br />4r_Orr <br />r_Orr <br />& <br />N <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />�4 <br />bo <br />EDGE OF SLAB 2" <br />BEYOND WALL <br />N <br />cc <br />S3 <br />2x6 WALL <br />D <br />S3 <br />cc <br />IO <br />I O <br />I ° <br />I <br />I W <br />I O <br />I n <br />I X <br />I <br />I <br />I <br />LIII - <br />I I <br />I I <br />II <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />IIII IIII <br />CN------------ <br />_ <br />L I-J <br />• • I . • <br />I <br />! <br />I� rl <br />JIL-----------�I <br />z3 <br />' <br />� <br />� <br />= <br />A � <br />N <br />I <br />3 <br />'-8' <br />FU <br />T C <br />G. <br />1 <br />� <br />-- <br />�2 <br />68 <br />- <br />- <br />6681B.F. <br />REF.EL24 <br />PANTRYOPT. <br />- <br />16" DEEP <br />5-SH <br />N <br />J <br />S6 TYP @ 2 STORY <br />H.B. T <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1 /4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1 /4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />* VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 j <br />S.H. <br />13 <br />20X38j <br />18}X37i <br />S.H. <br />14 <br />20 X 50 j <br />18 } X 50 <br />S.H. <br />15 <br />20X63 <br />18jX62j <br />S.H. <br />16 <br />20X72 <br />18}X71} <br />S.H. <br />11-12 <br />271/4X26 <br />26X25j <br />S.H. <br />1H3 <br />271/4X38 <br />26x37 <br />S.H. <br />11-14 <br />274X501 <br />26x50 <br />S.H. <br />11-15 <br />27jX63 <br />26X621/2 <br />S.H. <br />11-I6 <br />27 j X 72 <br />26 X 71 1/2 <br />S.H. <br />22 <br />37 j X 26 <br />36 } X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 } X 37 3/4 <br />S.H. <br />24 <br />37 j X 50 j <br />36 J X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 j X 62 1/2 <br />S.H. <br />26 <br />37 j X 72 <br />36 } X 71 1/2 <br />S.H. <br />DOUBLE 2 <br />WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 } X 25 � <br />S.H. <br />33 <br />54 X 38 j <br />52 j X 37 j <br />S.H. <br />34 <br />54 X 501 <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 4 <br />S.H. <br />36 <br />54 X 72 <br />52 j X 71 j <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED - EXPOSURE "C" <br />A+29.7 <br />/ -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />O <br />+28.3 / -36.4 <br />O <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />O <br />SEE SN SHEET O SEE SN SHEET <br />'� 40 MPH 0=01i <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />+34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-8" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION 1113111 <br />1ST FLOOR LIVING AREA 1093 <br />2ND FLOOR LIVING AREA <br />1489 <br />LIVING TOTAL 2582 <br />GARAGE 427 <br />FRONT ENTRY 35 <br />TOTAL AREA 3044 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONIC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 <br />R-19 KRAFT FACED <br />CONDITIONED CEILING <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION <br />j R-11/R-13 KRAFT FACED <br />(GARAGE / LIVING) <br />C9 V <br />z8 <br />z�® <br />z <br />< <br />gram <br />a <br />U) z <br />W <br />cn <br />w <br />•V <br />Ow <br />�� <br />U <br />�0, <br />m N <br />w <br />1 - <br />now=g? <br />pN�M <br />C s M <br />U �7S <br />000 <br />c `i o <br />¢ <br />8.� <br />Q d <br />Al <br />'IV <br />N N <br />� N <br />fA 00 <br />LC rezo <br />j LL 5 iii ,y <br />LU "'qB <br />W L' <br />Za <br />tv tl�#t I/ o <br />ul <br />s <br />�•���f,�rllJlD�i <br />I i i�!�4�4�.���� <br />To the best of the Engineer's knowledge, information and belief, <br />the Wuctural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www. LennarTampa.corn <br />6 <br />w <br />w¢oaC� <br />�z'00 <br />LU <br />LU <br />Z <br />J <br />Q <br />® <br />CL <br />Cr <br />g <br />0 <br />= <br />�.� <br />_ <br />ILL <br />W <br />o <br />J <br />Lr) <br />T <br />o00 <br />~P <br />o <br />N <br />LLJ <br />Z <br />Z <br />J <br />Ln <br />LLJ <br />0 �i <br />z <br />rl <br />LLI <br />rri <br />Q <br />z�� <br />� <br />Z8 <br />Z <br />tu- <br />0 <br />06 <br />g <br />= <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAMES <br />VERSION N0. 5ol <br />SHEET NO. <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.