My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2939 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2939 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 1:28:14 PM
Creation date
2/19/2025 8:49:00 AM
Metadata
Fields
Template:
Building Plans
Street #
2939
Location
Moulden Hollow Dr
Contractor
Lennar Home
Building Plans - Permit #
20616
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br />CC <br />aci <br />v <br />x <br />r� <br />ram', <br />KITCHEN <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS R <br />@ END OF LANDING <br />BELOW HDR. BEAM <br />STANDARD (3) 2x1 <br />a <br />STRINGERS w/ <br />SIMPSON A35/USP <br />o <br />i <br />MP34 CLIP TO <br />E. <br />FLOOR SYSTEM OI <br />9 <br />LANDING FRAMINC <br />8 <br />c <br />(2) 2x HDR. <br />= <br />REQ'D @ ENC <br />LANDING FOF <br />i <br />STRINGERS 1 <br />CONNECT TC <br />aC <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16-O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. o <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />I GENERAL LANDING FRAMING INFO. <br />00 <br />r`, <br />I <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />°Q <br />Zo <br />�— 2x8 LEDGER #2 SYP w/ <br />(3) 16d NAILS TO STUD <br />@ 16" O.C. <br />in <br />2x12 HDR. w/ (3) 2x STUDS AT <br />EA. END FOR BEARING <br />STANDARD (3) 2X12 <br />STRINGERS W/ SIMPSON A35 <br />CLIP TO HDR. <br />ix TREADS (TYP.) <br />CONT. <br />HANDRAIL <br />THRUST BLOCK SECURED TO <br />SLAB w/ 1/4"X3 1/2" TAPCONS <br />@ 16" O.C. <br />a <br />KITCHEN <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16" O.C. w/ SIMPSON A35 <br />CLIP OR LUS26 HANGER TO <br />LEDGER I U <br />Q <br />Q <br />w <br />J <br />U <br />O <br />MIRROR <br />a <br />a <br />o <br />a <br />OWNER'S BATH <br />0 <br />M <br />4 <br />fV <br />O <br />M <br />PPF_FKIr, FI OOP .1011CT W/ /91 <br />KITCHEN ISLAND <br />INTERIOR ELEVATIONS <br />SCALE: 1 /2"=1'-0" <br />STAIR CALCULATIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 9/16" <br />10" TREADS w/ 1" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 <br />inch and not more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing <br />projection shall not exceed the smallest nosing projection by more than 3/8 inch between two stories, including <br />the nosing at the level of floors and landings. Beveling of nosings shall not exceed 1 /2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located <br />more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to <br />the edge of the open side. Required guards at open -sided walking surfaces, including stairs, porches, balconies <br />or landings, shall be not less than 36 inches in height as measured vertically above the adjacent walking surface <br />or the line connecting the leading edges of the treads. Required guards shall not have openings from the walking <br />surface to the required guard height that allow passage of a sphere 4 inches in diameter. <br />Under -stair protection: <br />Enclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the <br />enclosed side with 1/2-inch gypsum board. <br />SCALE: 1 /2"=1'-0" <br />z01 <br />0 <br />z�z <br />Q <br />U) z <br />i---J cn <br />w <br />(1)(130 <br />V— <br />Ow <br />N c <br />T00 <br />V) <br />U <br />w <br />m N <br />M <br />U <br />"- o <br />,d .- <br />ur, <br />BD. <br />" <br />�ul' <br />N �O <br />I= Z <br />LU a y e IL <br />¢ ii a <br />Z'." <br />O IP lj <br />LL <br />s �! ❑ <br />o <br />cr�'•, <br />P <br />O F E S <br />��'f/�NII111111\`` <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />structuralthestructural engineering portions of the drawing Pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Sure 2001 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />Z Q <br />,u a <br />vZ U <br />alig <br />M <br />0 <br />3 <br />O <br />= <br />�./ <br />= <br />Cr <br />IWUJ <br />- <br />o <br />� <br />Z <br />�JZ <br />4"21, <br />L0 <br />1H <br />* <br />Lr) <br />� � <br />oC <br />Q <br />N <br />°` <br />O <br />Z <br />Ln <br />Z <br />ZZ8 <br />I- <br />co <br />rn <br />� <br />' <br />0o <br />Z <br />g <br />Itj <br />W <br />= <br />W <br />,--I <br />a <br />cn <br />s <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: M]AM ES <br />VERSION NO. 5ol <br />SHEET NO. <br />2.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.