My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2939 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2939 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 1:28:14 PM
Creation date
2/19/2025 8:49:00 AM
Metadata
Fields
Template:
Building Plans
Street #
2939
Location
Moulden Hollow Dr
Contractor
Lennar Home
Building Plans - Permit #
20616
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ir <br />Ni <br />r- <br />In <br />CD <br />cc <br />:_ <br />J <br />I <br />00 <br />4 <br />00 <br />r" <br />r— <br />ELECTRICAL SPECIFICATION 200A INDOOR PANEL <br />CENTER <br />NOTES: <br />014 copper to lights & outlets <br />NEMA 1 01 #12 copper to 20 amp das <br />ELECTRICAL CONTRACTOR MO AMP <br />MUST VERIFY WITH THE 10.2 copper to wN <br /># <br />SPECIFICATIONS FOR THE TYPE ,D3copper le Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR METER <br />LOCATION PURPOSES. MAIN T O <br />z,o or 4/0sER au <br />200 amp <br />150 amp IF <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance With FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />Liph <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />izn <br />220 VOLT OUTLET <br />WALL SWITCH <br />4�3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />e <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />(O <br />EXHAUSTFAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />l9 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />FO <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKEICARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />WWI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4'=1'-0" <br />U � <br />Z o <br />CD <br />Z `O <br />Z <br />Q <br />d <br />U) Z <br />vN <br />4-J W <br />� o <br />�V — <br />O W <br />Lh <br />2 <br />U <br />W <br />m� <br />N <br />C7 <br />04 <br />u-a <br />U <br />L"-00 <br />Q rn <br />_&o <br />rn & :S <br />ai Q o <br />D. <br />NN C� <br />•, <br />Z <br />U) LL o .� fs7 fi <br />100 <br />49 $ m° <br />WLLM a <br />N a <br />OU V O <br />YAW FDSENG COM O <br />Go <br />N <br />cu <br />0 <br />0 <br />To the beat of the Engineers knowledge, information and belief, <br />the structural plans and spedfications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal Is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />LENNAR <br />4600 W. Cypress St, Suite 200 1 Tampa, FL 33607 <br />www.LennarTampa.com <br />W <br />�a <br />z <br />f� <br />a � <br />L <br />; <br />F_ <br />�- <br />a <br />Z <br />LU <br />J <br />LIJ <br />Q <br />yW <br />U <br />= <br />J <br />Lr) <br />0 <br />J <br />LL5 <br />� <br />Ro <br />o. <br />z <br />t 0 Z_L <br />Ln <br />Nt�itWce <br />Q <br />Z <br />Z <br />J <br />Lij <br />< z <br />,Ln <br />-I <br />LJ.I <br />z <br />Z <br />Ua <br />�.8 <br />m <br />d- <br />r <br />Z <br />tj <br />W <br />Is <br />V <br />�W <br />O <br />0o <br />g <br />= <br />f <br />rn <br />.-a <br />a <br />to <br />E <br />SCALE : AS NOTED <br />DATE : 7/31 /2018 <br />TECH: MJAM ES <br />VERSION NO. 5ml <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.