My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3023 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3023 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:53:08 AM
Creation date
2/19/2025 8:49:16 AM
Metadata
Fields
Template:
Building Plans
Street #
3023
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
251
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />0-1 <br />UJ <br />15/32" CDX <br />Q <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" <br />WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />o <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ 4 <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />+ <br />+ <br />-0" (TYP.) <br />6'-0" <br />+ <br />+ + <br />+ + <br />6'-0" <br />+ <br />+ <br />+++ <br />+++ <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+++ <br />+++ <br />+ 4+ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + + <br />+++ <br />+ <br />+ + <br />+ + <br />+ + <br />+ <br />+ <br />+ <br />+ <br />/++ <br />4 <br />+ + <br />+ + <br />+ + + <br />++ <br />+ <br />+ <br />++ <br />++ <br />+ <br />+ <br />+ <br />+ + <br />in <br />+ <br />+ + <br />+ + + + <br />++ <br />+ <br />+ ++ <br />+ <br />++ <br />+ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8" <br />5000s 1.8/1.7 <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-118" or two 112" <br />602.0 <br />wood panels <br />2x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". <br />DOUBLE JOIST CONNECTION <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* over squash=20 blocks and <br />Non -stacking walls wall or beam below.* <br />require additional <br />consideration. Check <br />local building <br />code for appropriate <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />'� lateral load. nail each side <br />107 <br />0 -0 7 at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O O O <br />5'-0" <br />STUB -OUT FOR 1'-0'-o ° <br />GAS METER O o 'n <br />� U <br />9 ~O <br />cV = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X T @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />'IT-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />154" <br />(1) SIMPSON HTS20 OR (3) 16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />I Iqa T' 110r11 nail.. at R" n r._ <br />j, U/ Provide adequate bearing <br />J for each lapped joist. <br />10dnails SECTION @ INT. BRG. WALL <br />N.T.S. <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />le <br />(see table below) <br />DO NOT cut, notch <br />IK <br />or drill flanges <br />FILL CELL STD. 900 HOOK BOND BEAM <br />11 <br />U) <br />w <br />STD. 90° CONT. #5 <br />BAR —�5 > HOOK BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D <br />SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION <br />TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />%from <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />Solid block all posts <br />STUDS <br />above to bearing below. <br />SECTION <br />@ INT. BRG. WALL <br />N.T.S. <br />1/8" min. )Small gap 2" min. <br />2„ <br />max. � 4 max. <br />h� 0 <br />Clinch nails <br />when <br />possible <br />Tight fit U I� <br />2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series De th I End Intermediate <br />BC15000s® <br />9-1/2" <br />1 2-8d <br />2-8d <br />11-718" <br />2-8d <br />3-8d <br />14" <br />1 2-8d <br />5-8d <br />BCI 6000s® <br />BC16500s® <br />9-1/2" <br />11-718" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />I 5-8d <br />16" <br />2-8d <br />I 6-8d <br />BCI60sY" <br />11-7/8" <br />2-8d <br />I 3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />- Hangers with side nailing. <br />-Hangerswithsidesnotcontaining WEB STIFFENER <br />top flange of joist. <br />- Birdsmouth cuts. N.T.S. <br />- Under 2nd floor column w/ loads <br />higher than 15001b. <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 pif max. along bearing wall <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />kitWhen joists meet over wall, provide <br />�1 3/4" minimum bearing for each. <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration.- <br />6A 1%" ROUND HOLE MAY <br />BE CUT ANYWHERE IN CANTILEVER <br />THE WEB. PROVIDE AT <br />LEAST 3" OF CLEARANCE <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y" <br />NOTES: <br />DO NOT CUT HOLES <br />LARGER THAN 1Y" <br />ROUND IN <br />CANTILEVERS. <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1Y" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />5/8" 0 <br />THRU <br />BOLT <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />kt Joist <br />I -Joist can be offset <br />Eb <br />up to 3" to avoid <br />vertical plumbinge. <br />3" max <br />JOISTS OFFSET <br />N.T.S <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />\Install tight to top flange. <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />Backer Block <br />"Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />7. <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEMS ' <br />SEE PLAN FOR--'°• ° . • . <br />FOUNDATION INFO n' n' <br />STEM FOUNDATION <br />GRADE <br />REINF. SEE PLAN <br />WV ur1HJC 4 rvt, <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />:�® LOCATION OF <br />SECOND H10A <br />SIMPSON H10A (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT = 1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />d- a <br />G <br />I 'I I— r l l=1 a <br />12" BELOW <br />GRADE <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />a <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />4 d d <br />a n �—t <br />CO � <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />d ° na. a All G <br />a a <br />_I T� _ e <br />—� -TI I- <br />r r <br />Q <br />SEE FND. PLN. <br />SIZE & REINF. <br />brut N <br />SRO <br />1 <br />cry <br />.i; ) <br />=� <br />;— <br />c� , *- <br />,05-✓vlZl�7t+� <br />O F E S S tt) \\\eg <br />?tiff 111mel <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />MW h <br />W <br />®�♦♦ <br />�$ co <br />co <br />CO to <br />O O N# <br />0 <br />(0 <br />O rT co <br />M N N Lo °NO LL <br />�-� CIO <br />J W <br />N <br />0 <br />'0 <br />5 "LLa <br />a 0 <br />N M W N <br />0; p a s ul <br />> .` ul <br />Z <br />�coM o <br />o O <br />ag m <br />W <br />Z <br />M <br />2 Ec' B o a <br />M:g <br />N Q ccoo 2 U 0 J <br />Z <br />OU ❑❑❑ <br />W <br />z N O <br />z o <br />J Cl) <br />d N <br />to <br />M <br />z <br />T <br />w n 0 <br />o Q <br />cn <br />V) <br />o <br />' <br />V <br />o <br />u m <br />Lu m <br />c <br />,— ,� E <br />o <br />I <br />zl�... <br />= g8 <br />0 o <br />° <br />C_ <br />® 0 <br />¢ o <br />o <br />w <br />M <br />o <br />2 <br />Z <br />`_ <br />6 E <br />O <br />oo <br />Faa.� <br />zo <br />?® <br />Da <br />fCU <br />—CLa< <br />X0 <br />0U <br />U <br />O E <br />cV <br />az <br />o <br /><o <br />o< <br />Wz <br />ul <br />i <br />Y <br />U <br />N <br />m� <br />o <br />Z , <br />Z <br />J <br />m <br />d <br />Q W <br />2. <br />Ul <br />a i <br />0- <br />o <br />w <br />5o <br />a <br />�w <br />U <br /><0 <br />�k <br />w, <br />-0< <br />>° <br />o <br />V <br />a� <br />Oo3 <br />(D <br />>� <br />cm <br />W <br />`J <br />° <br />f6 <br />00 <br />/ <br />f0 <br />C <br />C) <br />U <br />^� m <br />Qi <br />V/ <br />V <br />C <br />T- <br />o <br />Z <br />2T <br />Lid <br />e- <br />00 <br />o N <br />r <br />ui <br />M <br />w <br />CV <br />M r <br />o <br />z <br />Z <br />E 1 <br />a <br />c <br />c <br />a <br />U 0 <br />Q p <br />(D <br />JOB <br />NO : <br />20-2747 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SN 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.