My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3023 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3023 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 5:53:08 AM
Creation date
2/19/2025 8:49:16 AM
Metadata
Fields
Template:
Building Plans
Street #
3023
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
251
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES, <br />200A INDOOR PANEL <br />CENTER <br />#14 copperto lights 1, outlets <br />00 A MP 200 A1 #12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN "11 <br />O2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217, <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />� wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�'4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />I <br />WALL MOUNTED LIGHT FIXTURE <br />QRECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />a <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />iIQX <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />PI3 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />_!a <br />ELECTRIC PANEL <br />_ r <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />a <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />Y )�I <br />PA I�O CAFE <br />I <br />OWNER'S SyIITE <br />N <br />/ ROUGH -IN FOR / <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I / <br />I <br />I ' <br />I <br />I ' <br />I <br />I <br />I ` <br />FAMILY R M , <br />/ <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />I LIGHT PRE -WIRE <br />I <br />U.C. OUTLET <br />FOR DW <br />I <br />U.C. OUTLET <br />74 <br />GFI <br />/--------_-_ -_-_-_--_�_--- — <br />/ GFI C---------- GF <br />I <br />/ �— <br />I O <br />D.W. I -i- <br />L___J <br />71PENDANT AS <br />PER SPECS \ <br />/ r <br />/ LO \ <br />/ <br />AC PAD / <br />WP H.B. <br />GFI DISC. <br />uGFI <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />iiGFI <br />1 <br />OPT. 14 <br />REF. <br />---I- <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />BEDROOM 2//� <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED y <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H. <br />4F IRRIGATION <br />VERIFY LOCATION FGFI @ 44" A.F.F. <br />Dw <br />ELECTRICAL PANEL <br />O I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOI <br />GFI I <br />GFI @ 44" <br />A.F.F. <br />I <br />I I <br />I A I <br />l <br />L - - - - <br />GFI @ 44" <br />4k A.F.F. <br />US.D. <br />S.D <br />ENTRY <br />I I <br />I I <br />I I <br />WP I I <br />/--OFl <br />BEDFtrOOM 31 } BEDROOM 4 <br />r ROUGH FOR <br />OPT. CLG. <br />FAN\ PRE -WIRE <br />� LIGHT PRE -WIRE <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ I <br />LIGHT PRE -WIRE <br />o <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-O" <br />o <br />CV <br />0 <br />N <br />c� <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />/ <br />co <br />to <br />00 8 V E N p�� <br />O O O a) <br />Ci <br />O <br />M N N C <br />CO N <br />to <br />Zo N LL <br />CIt o <br />fA <br />.�., <br />u_ — <br />LL a <br />�co0 <br />C' W <br />Z <br />c29 <br />0 1'- <br />t1° m O <br />m m <br />W <br />W <br />LL <br />ou <br />2 Ema> <br />s p a <br />rn_ca p <br />N Q M Z <br />trp y <br />= <br />V C) <br />Z <br />° V ❑❑❑ <br />W <br />N O <br />O <br />� o <br />N <br />a <br />Q) <br />CD li <br />4-J <br />'U <br />_� <br />a < <br />V) <br />Ln <br />u r r— <br />c E <br />NOs <br />t'13 <br />�- <br />u m <br />ro E <br />0 <br />—8 <br />s <br />U <br />Q 9 0 <br />0, <br />14 <br />` r <br />c <br />co <br />w <br />M <br />o <br />Z <br />� <br />E <br />�o <br />0 <br />>R <br />® <br />Z <br />Q <br />oa <br />Y <br />— <br />O E <br />a� <br />00 <br />00 <br />o¢ <br />0 (O <br />C14 <br />Q i <br />w Z. <br />ado <br />aZ <br />W Z <br />w:5 <br />cnr <br />- <br />z <br />U <br />N <br />mo <br />oLL <br />Z <br />N <br />m <br />F <br />Q W <br />ZZ <br />ga <br />aLtni <br />O- <br />U <br />o< <br />aLL <br />2 <br />a <br />nw <br />F <br />Q U <br />aZ <br />_ <br />w��°_ <br />Millo <br />o <br />v <br />ap <br />z¢ <br />o� <br />03 <br />m <br />W <br />m <br />0 <br />c <br />00 <br />`° <br />N <br />l/ <br />C U <br />D <br />^, m <br />8i <br />' <br />V <br />T <br />rp <br />Z <br />T <br />�.C� <br />r <br />it OO <br />O N <br />� <br />ai <br />E <br />� <br />N <br />M r <br />o <br />Z <br />E Q <br />mc <br />tp <br />d <br />E <br />U <br />a « <br />Q p <br />c <br />JOB <br />NO: <br />20-2747 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.