My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3026 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3026 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:59:26 AM
Creation date
2/19/2025 8:49:30 AM
Metadata
Fields
Template:
Building Plans
Street #
3026
Location
Nubbin Ridge Ln
Contractor
Lennar Home
Building Plans - Permit #
392
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f` <br />3 <br />-n <br />m <br />as <br />co <br />0 <br />.� <br />r to <br />LO <br />W3 <br />N <br />N <br />0 <br />0 <br />a <br />0 <br />0 <br />L <br />LO <br />LO <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: NTS <br />TRUSS NOTES: <br />CON1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2014 MAY B FRAMED RIDGE <br />TRUSS PLATE INSTITUTE NOTE THAT THE COMBINED WIND AREA IS GREATER MAYBE NAILED <br />( ) w/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST PRE-ENG. TRUSS <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED w/ (3) 12d <br />NAILS AT EACH TRUSS INTERSECTION. CB—_ <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. Dg <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />2X4 BLOCKING <br />2X4 DIAGONAL AT 8'-0" O.C. BETWEEN EA. TRUSS <br />MAX & EACH END ALTERNATE <br />DIRECTION TYP. 1 A <br />WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: NTS <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />2X4 CONT. AT <br />T & B CHORD <br />WOOD <br />TRUSS <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A —A <br />G.T. � <br />ADD 2X4 ALONGSIDE — <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />�A TRUSS <br />HIP <br />G.T <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />VERTICAL SCAB 2 x 6 <br />#2 SPF 48" O.C. W/ (4) <br />10d TOP & BOTTOM <br />OR SIMPSON H2.5A w/ <br />(10) 8d NAILS <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2x4 SPF 2 (2) #7 x 3-1/2" <br />WOOD SCREW EACH <br />TRUSS OR SIMPSON <br />H2.5A w/ (10) 8d NAILS <br />AT 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />2x8 #2 SPF RIDGE BEAM <br />• 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"0.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO TIE BEAM <br />CONC. MASONRY <br />STEEL OR WOOD <br />BEARING SUPPORT <br />A -A ALTERNATE BLOCKING <br />DETAIL @INTERIOR BEARING <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />SCALE:NTS <br />SIMPSON LSTA18 <br />w/ (12) 10d NAILS <br />CENTERED AT <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INF( <br />SCALE: NTS <br />>IMPSON HUC410 w/ <br />6d INTO HEADER & <br />Od INTO BEAM - SEE <br />GOOF PLAN FOR MOI <br />NFO <br />SEE FLOOR PLAN F <br />COLUMN SIZE & BA <br />CONNECTION INFO <br />(2) 2x8 #2 SYP w <br />O.S.B. FLITCH PI <br />TOP @ TRUSS B <br />U.N.O. ON ROOF <br />PLAN <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN w/ (2) SIMPSON <br />HTS20 w/ (24) 10d x 1 1/2" <br />NAILS EACH <br />SIMPSON HU46/HUC46 w/ (8) <br />16d NAILS TO POST & (4) 10d <br />NAILS TO BEAM <br />SUPPORT COLUMN BUILT-UP <br />(2) 2x4's OR 4x4 w/ (2) 10d <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) SIMPSON HETA20 w/ (8) 10d <br />x 1 1/2" NAILS EACH - OR (2) <br />SIMPSON MSTAM36 w/ (7) 10d <br />& (4) 1/4"x2 1/4" TITENS EACH <br />TIE BEAM <br />BEAM a@ RAISED ENTRY <br />MASONRY WALL 4 <br />SCALE: NTS <br />7/16" OSB FLITCH PLATE SEE FLOOR PLAN FOR <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />INDICATED ON OPTION A SCHEDULE/PLANM OPTION B CONNECTION INFO — <br />COMMON BM. TO POST ATTACHMENT / <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />SIMPSON MTS18 w/ (14) <br />10d NAILS TYP. U.N.O. <br />SEE FLOOR PLAN FOR — <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />CORNER <br />A A <br />SEE PLAN FOR <br />SEE PLAN FOR <br />CANTILEVER IF <br />INDICATED <br />SEE FOUNDATION <br />° PLAN FOR MORE INFO <br />SCALE: 3/4"=V-0" <br />COMMON BM. ATTACHMENT 1s <br />SCALE: NTS <br />SEE PLAN <br />FOR CANT. <br />—7/16" OSB FLITCH PLATE <br />REQ'D ONLY WHEN <br />INDICATED ON BM. <br />SCHEDULE/PLAN <br />OPTION C <br />BM. SPLICE OVER <br />�� CENTER OF POST <br />MIDDLE <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE DETAIL 4/D1 <br />FOR BEAM SIZE <br />EXTERIOR SHEATHING XH <br />ATTACHED PER NAILING <br />SCHEDULE 2x SPF #2 <br />AT 16" O.C. <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />KNEEWALL aC� ENTRY FRONT WALL <br />SCALE: NTS <br />2X4 #2 SYP NAILER. NAIL <br />TO STUDS w/ (3) 16d AT <br />EACH STUD - TOENAIL ROOF AND EXTERIOR <br />EACH TRUSS TO NAILER SHEATHING ATTACHED <br />W/ (3) 10d PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />IF 2x DOUBLE LEDGER, <br />ATTACH FIRST PLY <br />W/ (4) 16d NAILS TO EA. <br />END OF TRUSS THEN <br />ATTACH SECOND PLY <br />W/ (3) ROWS OF 16d <br />NAILS AT 24" O.C. <br />SIMPSON LUS26 w/ (8) 10d NAILS <br />OR IF 2 PLY TRUSS SIMPSON <br />LUS26-2 w/ (8) 16d NAILS TO SEE FLOOR FRAMING PLAN <br />LEDGER AND J/S6 FOR MORE INFO. <br />2X10 #2 SYP CONT. LEDGER w/ (3) VERIFY WITH PLAN FOR <br />1/2" X 4 1/2" LAG SCREWS ATTACH LOCATION AND DIRECTION <br />LAG SCREWS INTO END OF EACH (IF PARALLEL SEE 2/D2 FOR <br />FLOOR TRUSS, 24" O.C. MAX. (AT BLOCKING INFO) <br />EACH SIDE OF G.T. INSTALL (4) LAG MASONRY WALL <br />SCREWS EACH SIDE) (TYPICAL) <br />SECTION AT LOW ROOF 9 <br />SCALE: NTS <br />VARIES <br />2x STUDS @ 16" O.C. <br />ROOF SHEATHING <br />SEE 1/S5 FOR <br />SEE PLAN FOR <br />w/ SIMPSON SP1 w/ (10) 10d <br />ATTACHED PER <br />ADDITIONAL <br />8d NAILS AT <br />VALLEY TRUSS <br />NAILS AT BASE & SIMPSON <br />2x4 #2 SPF BRACING @ <br />NAILING SCHEDULE <br />OUTLOOKER <br />4" O.C. <br />SP2 w/ (12) 10d NAILS AT TOP <br />EXTERIOR SHEATHING <br />INFO. <br />16" O.C. W/ (4) 12d <br />COMMON TRUSSES. <br />ATTACHED PER <br />2x BLOCKING BETWEEN STUDS <br />TOENAILS TO TOP <br />SEE TRUSS PLAN <br />2x4 STUDS w/ SIMPSON <br />NAILING SCHEDULE <br />TO TRUSS W/ (2) 12d TOENAILS <br />STRUCTURAL SHEATHING <br />PLATE & (2) 12d END <br />MIN. (2) 2x4 <br />FOR CONNECTION <br />SP1 w/ (10) 10d NAILS <br />EACH END ( BETWEEN TRUSSES <br />ATTACHED PER NAILING <br />NAILS TO TRUSS <br />SPF TOP <br />INFORMATION. <br />AT BASE SEE J/S6 FOR <br />GABL <br />LOW ROOF/WALL <br />(2) 12d NAILS TO EACH VERTICAL <br />SCHEDULE <br />BOTTOM CHORD <br />PLATE <br />MORE INFO. <br />TRUSS <br />SHEATHING ATTACHED <br />STUD) <br />VARIES SEE PLAN <br />PER NAILING SCHEDULE <br />2x BASE PLATE W/ (2) 12d <br />VARIES W/ <br />FOR WALL LOCATION <br />2x4 BASE PLATE W/ <br />1/2" PLYWOOD <br />NAILS @ 16" O.C. ALONG W/ <br />ROOF SLOPE <br />SIMPSON LSTA30 w/ <br />SIMPSON MTS12 w/ (14) 10d x <br />(22) 10d NAILS OR <br />(2) 16d NAILS TO <br />1 1/2" NAILS TO BLOCKING <br />WOOD WALL <br />SIMPSON MTS12 w/ <br />EACH COMMON <br />BELOW @ 16" O.C. <br />OR TRUSS. <br />2X4 CONT. W/ (2) <br />MIN. 2x4 #2 SPF STUDS @ <br />(14) 10d x 1 1/2" NAILS <br />TRUSS/ FRAMING <br />TYP TOP &BOTTOM <br />-a. <br />SEE PLAN <br />16d COMMONS <br />16" O.C. W/ EXTERIOR <br />TO FLOOR GIRDER <br />NAILS EACH <br />SHEATHING ATTACHED <br />BELOW @ 16" O.C. <br />P::\\ <br />X� <br />STUD TYP. T&B <br />PER NAILING SCHEDULE & <br />• MASONRY WALL BELOW: SIMPSON <br />PLYWOOD <br />(3) 12d TOENAILS TO <br />a°, <br />HETA16 w/ (9) 10d x 1 1/2" NAILS @ <br />FLOORING <br />TRUSS OR <br />SEE PLAN FOR <br />PLATE BELOW <br />MASONRY WALL <br />A <br />4'-0" O.C. TO GABLE TRUSS <br />ROOF SYSTEM <br />TOP OF WALL <br />; <br />OR BEAM <br />. BEAM BELOW: SIMPSON HTS20 w/ <br />MIN. 2x4 #2 SYP P.T. PLATE <br />16" FLOOR SYSTEM <br />FLOOR GIRDER <br />SEE TRUSS PLAN <br />a° <br />(24) 10d x 1 1/2" NAILS @ 4'-0" O.C. <br />W/ 1/2"X8" EPDXY ANCHOR <br />SEE PLAN FOR <br />SEE PLAN FOR <br />TO GABLE TRUSS <br />LOW ROOF TRUSS W/ <br />(2) 2x6 BLOCKING UNDER FLOOR G.T. <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />DIRECTION <br />CONNECTION <br />a <br />COMMON TRUSS <br />RAISED BOTTOM CHORD <br />2nd FLOOR WALL w/ SEE PLAN <br />PLAN FOR MORE <br />16" O.C. MAX. <br />SEE ROOF PLAN <br />EXTENSION SEE TRUSS <br />SIMPSON LUS24-2 w/ (16) <br />SHEAR <br />TRANSFER <br />INFO. <br />�� <br />SECTION FLOOR <br />FOR CONNECTION <br />MANUF. SPEC'S FOR <br />16d NAILS AT EACH END <br />@ <br />CONNECTIONS TO G.T. <br />EXTERIOR. WALL <br />SECTION <br />ENTRY <br />s <br />CONNECTION <br />22 <br />SECTION <br />AT HIP <br />GABLE 12 <br />SECTION <br />BUMP OUT 39 <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />SCALE: NTS <br />DETAILS & SECTIONS <br />I <br />i <br />co <br />e nI <br />'•�iLi <br />c <br />C) <br />aQo3 <br />r <br />* <br />:U <br />• <br />U •� <br />PROF <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />..g -W <br />co <br />I•• <br />Q <br />� U N � co <br />O O O N i k <br />v <br />C7 8 N J <br />M N r a) U m u- <br />® <br />to <br />.�M�� J W <br />SUu- _ a <br />N <br />a <br />N <br />y M W N <br />a) L 3 a a <br />t9 <br />Z <br />'- <br />¢C zzx <br />�0.8 0O K F <br />I <br />� CO m m O <br />0 WCO <br />2 n Eco Qa <br />< <br />g <br />N Q O <br />N Q co Z U FIL J <br />Z <br />OU ❑❑❑ <br />W <br />I <br />jaV <br />z N O <br />W <br />z W NN <br />z O Q <br />a <br />J M <br />d N <br />z <br />o <br />C1 <br />4� <br />�N <br />- <br />4-- <br />f� <br />U%u_ <br />Y <br />w o <br />j� <br />'�+ <br />O <br />V <br />`° <br />ELn = N <br />U m <br />a� <br />w C <br />Nook <br />U o <br />Q 9 o <br />0 <br />o <br />W <br />co <br />M <br />a <br />p <br />ZZZ <br />Q E <br />E <br />o� <br />Zo <br />Z� <br />oa <br />uCU <br /><0w0 <br />I— @ <br />210 XU <br />�OV <br />N <br />L <br />a p <br />°do <br />L <br />wz <br />ro <br />U) C <br />Q < <br /><Zo <br />U <br />h <br />ro <br />LL <br />U) <br />m <br />Q W <br />Z <br />a) <br />Q <br />oM <br />LL <br />ao <br />m w <br />T <br />U <br />K <br />0 <br />�E <br />2 H <br />~� <br />Y O <br />CD <br />C.0 <br />�t <br />zl¢ <br />a <br />0 <br />00 3 <br />.� M <br />J <br />> M <br />bi <br />rn <br />2 <br />Al <br />W <br />@ <br />./ <br />� <br />Cfl <br />L•L <br />CN <br />^ <br />Q <br />0 <br />0 <br />�1 <br />'p <br />(0 <br />op <br />2 <br />'W <br />G <br />.41- <br />T <br />N <br />C:) <br />L0 <br />V <br />Z N <br />r <br />L{) <br />�n <br />LO <br />N <br />N LO <br />•— <br />ai <br />w CD <br />o LO <br />co <br />o <br />E <br />co <br />N <br />z <br />z <br />E O <br />E <br />E <br />N <br />2 <br />m <br />a <br />a <br />U <br />Q p <br />JOB <br />NO: <br />20-3576 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />D1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.