My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3026 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3026 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 11:59:26 AM
Creation date
2/19/2025 8:49:30 AM
Metadata
Fields
Template:
Building Plans
Street #
3026
Location
Nubbin Ridge Ln
Contractor
Lennar Home
Building Plans - Permit #
392
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA 1 <br />200 AMP <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copperto WH <br />#10-3 copper to Dryer <br />2/0 or 4/0 SER Alu <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />o #4 GROUNDING WIRE <br />TERMINATION PER <br />�1 WITH CODE APPROVED <br />NEC 14, 250.94 <br />---/// CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13, All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEF <br />DUPLEX OUTLET ABOVE COUNTER <br />� WP <br />WEATHERPROOF DUPLEX OUTLET <br />1GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />�4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />R D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />VtKlt-Y Mt I LK <br />CH CHIMES (OPTIONAL) LOCATION WITH <br />BUILDER <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />C0 CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />N TELEVISION (OPTIONAL) <br />2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />!� THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />i <br />DISCONNECT SWITCH <br />�44/� <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G r J <br />OPT. CEILING FAN <br />E�9 <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4'=1'-0" <br />Zj <br />0 <br />[V <br />0 <br />CV <br />v <br />0 <br />co <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition, Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />vE <br />00 <br />00 <br />CD <br />O V '• <br />009 rn <br />N Co # <br />to <br />U <br />i.i <br />co r- C <br />c'n N <br />N <br />O LL <br />—t _t W <br />v <br />p <br />) LJL.. c- <br />LL. LJL p_ <br />r� <br />uS "' <br />LL <br />-arn <br />� <br />W (n <br />t0l <br />W> ] <br />WO13 <br />�o� <br />Wa <br />rn <br />2E°'Bo <br />ma <br />LLWoN <br />V c) <br />¢ O Ln <br />Z <br />NQo7Z <br />O F J <br />❑0❑ <br />b; y W <br />M � <br />N M <br />< o <br />� N <br />-d <br />ch <br />r= <br />o <br />Q) <br />— <br />cn s <br />a <br />n <br />0 <br />V) <br />rr E <br />o <br />N <br />ue. <br />f6 <br />c) m <br />anm <br />S <br />f <br />� <br />`C 8 <br />®t <br />14 <br />o <br />w <br />Ch <br />o <br />Z <br />Q <br />i <br />E <br />w� <br />�.° <br />g <br />:z <br />E: 8 <br />?a <br />o a <br />fcu <br />o <br />o <br />x o <br />oa <br />ao <br />O <br />o� <br />°z <br />N <br />¢ <br />r <br />L <br />o <br />U <br />yO <br />m o <br />Z <br />Q% <br />Q u, <br />W <br />SD <br />o <br />zo <br />a8, <br />Q <br />LL <br />a <br />N <br />c� <br />< o <br />az <br />w <br />=� <br />c� <br />}o <br />o <br />co <br />z <br />a <br />0 <br />`M <br />= <br />(' <br />J <br />rn <br />N <br />n' <br />W <br />N <br />0 <br />N <br />.! <br />to <br />^ <br />Q <br />J <br />10 <br />O <br />m <br />10 <br />(0 <br />V <br />C:, <br />0 o <br />Ln <br />Ln <br />. � <br />Z N <br />u-) <br />r <br />L i <br />N <br />N 7 <br />r <br />(0 <br />o LO <br />M <br />o <br />E <br />E <br />CV <br />z <br />Z <br />E <br />E <br />to <br />4; <br />co <br />_ <br />cc <br />a. <br />U _j <br />Q p <br />JOB <br />NO: <br />20-3576 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.