Laserfiche WebLink
IF <br />N <br />ti <br />COMPOSITION SHINGLES <br />ROOF INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />ti <br />1'-2111 <br />4 <br />T.O.P. ----- <br />2nd FIN. <br />T.O.M. <br />F.FL. <br />1 '-011 <br />----�- - <br />1 <br />8'-0" RIDGE VENT <br />12 <br />5� <br />/ <br />/ <br />/ <br />/ <br />12 / <br />/ <br />/ <br />5 - <br />/ <br />/ <br />/ <br />/ <br />/ <br />/ I <br />/ <br />/ I <br />/ <br />12' RIDGE VENT <br />12 <br />�5 <br />T.O.P. <br />HDR HGT. <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />- - 1-0 - I1 <br />2nd FIN. FLR. <br />T.O.M. <br />F.FL. <br />CJ <br />CJ / WEEP <br />25 SH <br />TEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />(TYP.) <br />12 <br />�5 <br />\ <br />\ <br />\ <br />\ <br />12 <br />\ <br />\ <br />\ <br />I \\ <br />\ <br />\ <br />\ <br />---- --------------- <br />4' RIDGE VENT <br />25 SH <br />12 <br />�5 <br />— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — <br />1'-0" <br />REAR ELEVATION - Al <br />SCALE: 1 /4"=1'-0" <br />RIGHT ELEVATION - Al <br />SCALE: 1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />z� <br />0 <br /><C <br />J <br />V) <br />�Lw <br />r o <br />O LU <br />V) <br />E <br />Ln <br />� <br />m ti <br />N M <br />LU <br />~ E <br />C)l.J..l <br />C N M <br />O O N <br />= dj <br />U W <br />t LL 00 <br />in Q ~ <br />r�0 <br />aCrn <br />�a� <br />rnQo <br />Al <br />N C B D C <br />B <br />®® <br />te N <br />'�+•"" <br />ci <br />UM z <br />z <br />V !,a-om %1- <br />m <br />+ <br />LL Ns �+�°y ♦ ♦ <br />W <br />o E S S <br />Q� 11 <br />�w <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />z0 <br />0 <br />ate+ <br />> O <br />M <br />Q - Ln <br />.0 <br />( N <br />Lo <br />Q LL <br />F' a � M <br />oC U Q <br />z <br />W <br />_J0 <br />oz <br />�o <br />z C <br />z� <br />f <br />W <br />Wa0: a: <br />UZOU <br />OZ <br />LU LLA <br />-. <br />g ul <br />OW. <br />8 <br />o �W!i L <br />/�/� <br />W <br />iNi <br />mLUO <br />L <br />W <br />OO <br />w <br />zz <br />} o <br />� <br />N <br />o <br />g <br />an3 <br />t <br />W <br />O <br />.� <br />_ <br />z <br />< <br />z <br />�¢ <br />�. <br />rr <br />z <br />o u <br />p z <br />J <br />a' <br />W/� <br />X x86 <br />W <br />U Y m o. <br />Q a <br />N <br />a <br />Lu z <br />Q <br />v <br />UJ <br />~ � E M <br />z <br />�a o <br />W <br />_I <br />L0 <br />r-+I <br />Z <br />LJJ <br />Q <br />z <br />���n <br />F u O <br />V, <br />9zZ <br />,-I <br />rsi <br />N <br />z <br />�'- <br />z <br />0cc) <br />� <br />00 <br />� <br />W <br />Z <br />SCALE : AS NOTED <br />DATE : 1 /4/2018 <br />TECH: ERAN D <br />VERSION NO. 10 <br />O <br />SHEET NO. <br />3.2 <br />