My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3027 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3027 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 1:28:14 PM
Creation date
2/19/2025 8:49:45 AM
Metadata
Fields
Template:
Building Plans
Street #
3027
Location
Moulden Hollow Dr
Contractor
Lennar Homes LLC
Building Plans - Permit #
20290
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A,_ <br />d <br />ELECTRICAL SPECIFICATION <br />zooA INDPANEL <br />CENNTETE R <br />NOTES: <br />#14 copper to lights &outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 <br />200 AMP <br />#12 Copper to 20 amp ckts <br />MUST VERIFY WITH THE <br />10 #10-2 copperto WH <br />SPECIFICATIONS FOR THE TYPE <br />10 #10.3 copper to Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />LOCATION PURPOSES. <br />MO <br />2/0 or 4!0 SER Alu <br />200 amp <br />IT <br />150 amp <br />POWER CO. FEED._ <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />Fff <br />DUPLEX OUTLET ABOVE COUNTER <br />W P <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />rwl- <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />;Q, <br />EXHAUST FAN/LIGHT COMBINATION <br />© <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />El <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />FTq <br />TELEVISION (OPTIONAL) <br />TV 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />_=Lj <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />ENTRY <br />V CRII- T IVIC 1 CR <br />LOCATION WITH <br />BUILDER <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0��,_ <br />Z M <br />— O <br />z <br />�C <br />J <br />a <br />U) z <br />0 <br />) CD <br />T� w <br />O <br />T <br />E <br />o <br />~ <br />U <br />0 <br />m n <br />_ <br />~ E <br />— 8 <br />mM <br />Lu-0N <br />o 0 <br />Z <br />U$ <br />M <br />�Qti <br />0 <br />Q <br />0 <br />1,() 8V <br />0) <br />Q <br />=> <br />U5 <br />� <br />Z CD o0 <br />_au <br />Z d M W Z <br />C <br />Q in N& a N <br />LU <br />LU via. - <br />Ck <br />w w <br />W <br />-2 <br />Z 0�pow <br />Z N W oho <br />o <br />m m <br />LL a �Q� <br />J o <br />W N M <br />0 <br />O v <br />U I— <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />0 <br />0 <br />Z fV <br />0 N N <br />F-4 4-' O <br />? U- M <br />Z <br />M <br />Q��U') <br />a cn •� Ct' <br />W ON <br />Q L_ lL <br />IY U 00 <br />0-00 <br />Q <br />Z <br />W <br />J� <br />d- <br />�Z <br />jo <br />zaa <br />E¢ <br />Zzof <br />UWI <br />/18�W <br />( 11 \ <br />.M/. <br />< <br />d W 0. <br />oLLJ�004 <br />U <br />u M 0 <br />L <br />W <br />oZ <br />Z O <br />N <br />I— <br />i z <br />w <br />C <br />J <br />Ln <br />W <br />� <br />a <br />U <br />_ <br />O <br />.�� <br />O <br />JILL <br />uj <br />O <br />o <br />YN <br />�,s <br />Z <br />V.2ma <br />oaoa <br />N <br />Q <br />W J <br />ZLu <br />< <br />- <br />Q 0 M: C:1 <br />Z <br />Z <br />aft <br />W <br />W <br />Lr) <br />r-i <br />�<c� <br />Z 8 <br />-J <br />lJ 1 <br />Q <br />o <br />L <br />wLuZ <br />T -i <br />N <br />Z <br />� <br />O� <br />Z <br />M <br />Z <br />W <br />z <br />VLu <br />CL <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO- 10 <br />O <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.