Laserfiche WebLink
I 1 11 1 II'l llll 111 III 111yqIIY nll 1110 P I IIII11'...'. 11111111 1.'1_lll_'1 P I IP 1 INMII! III 11 911 1 1 IL' 1 1 1 _ " 1. I I�_ 1�11191F'?'ll'fI N71111111N ILII _ _ <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />J <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />RIDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE <br />140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS <br />8d RING SHANK NAILS @ 6" O.C. EDGES& <br />8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER <br />0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH <br />16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER <br />0,280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH <br />2 INCH NAIL LENGTH <br />NOTE: * FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAYBE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ + <br />+ + <br />+ + + + + + + <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />6'-0" <br />+ <br />6'-0" <br />+ + <br />+ + <br />+++ <br />+++ <br />+ <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ <br />+ <br />+ <br />+ + <br />+ + + + <br />+ <br />+ <br />+ <br />+ <br />+ + <br />+ + <br />++ <br />+++ <br />++++++++ <br />+ <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x _ lumber <br />Double 2 x _ lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking / <br />1/8" gap <br />FILL CELL- STD. 90* HOOK BOND BEAM <br />11 <br />SIMPSON MGT h <br />w/ (22)10d <br />w7 <br />NAILS TYP. GIRDER TRUSS <br />j STD. 90. CONT. #5 <br />BARHOOK BAR 2X TOP PLATE <br />5/8" � <br />#5 CONT. THRU <br />FROM BOLT <br />FOUNDATION <br />TO HIGHEST <br />BOND BEAM <br />v BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br />Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" max. � 4" max. <br />PJ d <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2" min. <br />required when indicated or 4" max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING �" GAP @TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouth cuts. N.T.S. <br />- Under 2nd floor c-Il Imrt ur/ Ingle <br />N.T.S. <br />SQUASH BLOCKS AT INTERIOR <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Load bearing wall must stack <br />* over squash=20 blocks and <br />Non -stacking walls <br />require additional wall or beam below.* <br />consideration. Check <br />local building <br />code for appropriate 1/16 <br />details in One 10d box <br />areas=20 of high or=20 sinker <br />lateral load. nail each side <br />10 -0 at bearing. <br />TANK -LESS W/H <br />CORNER OF <br />HOME H C G <br />GARAGE SIDE O 0 0 <br />5'-0" ¢ - <br />STUB -OUT FOR 0 1'-0" 0 9 ;n <br />GAS METER a <br />O <br />i:V = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-Y <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" 16" O.C. <br />16'-5" <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) SIMPSON HTS20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />164' <br />(1) SIMPSON HTS20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam <br />Boise Joist Blocking <br />Use 3" (10d) nails at 6" o.c. <br />Provide adequate bearing <br />for each lapped joist. <br />10d nails SECTION @ INT. BRG. WALL <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />higher than 15001b <br />BLOCKING PANEL, INTERIOR <br />Vertical load transfer =1900 plf max. along bearing wall <br />Required on interior walls: - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />beam below Load bearing wall must stack over <br />blocking and wall or beam below.* <br />Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />require additional consideration. — <br />6" A 1/" ROUND HOLE MAY 6" 6'1 DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN <br />Any 16" joist 12 1'-0" 1'-1" 1'-2" 1'-2" V-3" 1'-9" 2'-4" 2'-11" 3'-7" 4'-2" 4'-9" 5'-4" <br />Span (ft) 16 1'-0" 1'-T' T-2" 1'-2" T-T' 2'-5" 3'-2 3'-10' 4!-9" 5'-7' 6'-4" T-2" <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAYBE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. 1%" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION, USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BC15000s <br />9-1/2" <br />2-8d <br />2-8d <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BC► 6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC160sP <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BC190s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />LC <br />SIMPS( <br />w/ (22) <br />NAILS 1 <br />TYPICAL SIMPSON MGT TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL SIMPSON LUS/HUS/HUC <br />INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL SIMPSON HETA20 / <br />Plumbing HETAL20 INSTALLATION <br />Joist <br />When joists meet over wall, provide <br />13/4" minimum bearing for each. I -Joist can be offset <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />N.T.S. <br />Jc <br />Backer block (12" wide min.) <br />Nail with 10-10d nails. <br />Install tight to top flange. <br />\ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap <br />—J—ZKBacker Block <br />'Top Mount" "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4%2" gap at bottom of top <br />flange. flange. <br />Web stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />p depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />SLEEVE THRU STEM-` ° <br />SEE PLAN FOR °• a • • ° <br />FOUNDATION INFO 4 ° a <br />STEM FOUNDATION <br />GRADE REINF. SEE PLAN <br />n <br />12 <br />M1 I 1=1 11— 1 ' <br />II�III1 °�a 1�I-1_ <br />II—IT. <br />� <br />h <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />SIMPSON HETA20 / HETAL20 <br />INSTALLATION a@ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />//"> S.P.F. <br />LOCATION OF <br />SECOND H10A <br />SIMPSON H10A ° ° (WHEN <br />w/ (18)10d x 1 1/2" ° REQUIRED) <br />NAILS <br />UPLIFT =1015# <br />TYPICAL SIMPSON H10A <br />INSTALLATION <br />TYPICAL SIMPSON MTS <br />/ HTS INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />MI Mr \ IP'-P1T10% A I TI Ir-N1 1 r-k Ir% <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE—\ <br />PENETRATION <br />q A <br />PVC OR SCH40 SLEEVE <br />/—PLUMBINGE <br />LINE <br />a <br />a _.�a'A : a <br />CO Z •d •.• <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />d 4O' ° / eeA.G <br />a 4 <br />° °. a n <br />d <br />' T <br />d <br />SEE FND. PLN. <br />SIZE & REINF. <br />0VVr <br />>` ' <br />«• 4t 11, <br />LU <br />O,' E S S 10 <br />\\ <br />r/rf en t tl � 11 tt`��1�A <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />Q <br />Coho m CopCpop <br />O V V N N it <br />W <br />'I 0 <br />CCD)000l <br />N <br />,� U. u_ a <br />M <br />Q <br />Z <br />N W rn <br />>mLL aair <br />ac�� 0S o <br />Wm <br />@ago X,m0 <br />m m <br />usILW <br />01 f <br />Eg & X 0 a <br />Fc <br />Z� <br />N° 6 0� <br />NQMZ U I— J <br />Z <br />U ❑❑❑ <br />W <br />I <br />(D <br />�o <br />_ <br />z <br />o <br />Imam <br />z <br />J th <br />d. N <br />V ll <br />4--+ <br />"' <br />o <br />to <br />1l <br />r o <br />Z <br />w m <br />8 <br />.. <br />-1-0 <br />zl <br />¢ 8 <br />�m <br />t <br />w <br />Mz <br />� <br />J <br />E <br />� <br />N <br />O- O <br />E U <br />0 <br />-, �' <br />Z <br />o a <br />ca <br />o <br />cV <br />i.0° <br />a8 <br />Q°z <br />0 <br />O� <br />wz <br />Q% 1- <br />(o <br />ao <br />¢ . <br />z <br />aLq <br />m 2 <br />O <br />Cl)C <br />- v <br />i <br />O Y <br />U <br />y O <br />01 <br />Z <br />J <br />¢ ° <br />Q W <br />z <br />to <br />/n <br />N 3 <br />0 <br />O <br />az <br />U <br />i <br />y� <br />1k <br />3 <br />J <br />� <br />CD <br />J <br />acz) al <br />=� <br />12! <br />;o <br />x <br />Q0 <br />$Ia <br />a <br />o 3 <br />°N <br />>� <br />Ix <br />L <br />N <br />2 <br />^1 <br />W <br />@ <br />c� <br />N <br />c <br />LL1L. <br />J <br />� <br />N <br />^ <br />Q <br />^ <br />L <br />0 <br />O <br />o <br />/�1 m <br />-0 <br />2 <br />(� <br />d' <br />N <br />.� <br />T <br />z N <br />T <br />r <br />LO <br />M <br />C) N <br />V— <br />iD <br />N <br />M <br />� <br />o <br />Z <br />z <br />E 0 <br />E <br />U <br />c <br />a <br />U <br />JOB <br />NO : <br />20-2746 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />SIN 1 <br />