Laserfiche WebLink
ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />E <br />See lev <br />( ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />19.000000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />561.0 <br />285.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />ROOF PLAN - ELEV-Al <br />SCALE: %4"=l'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ, IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />No. <br />e <br />* <br />� F O <br />E S S t <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's <br />signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />E 00 <br />Q <br />_ Zo 8 <br />O N <br />Lo 0 <br />4 M (D <br />M N r_ N# 00 Lt <br />� C"- a : t W <br />U).5 <br />� 2 u— - <br />M <br />13 <br />�j S W LU <br />y a. <br />Z <br />v�� ZO <br />a�9 m00p <br />W <br />Lcoo <br />iE°�'rn Boa <br />z <br />LD <br />v ¢O <br />N¢ m Z O F <br />z <br />°� DO❑ <br />W <br />z N O <br />z N <br />� � <br />z <br />Q M <br />� N <br />ur) <br />_ M <br />z .o <br />— <br />—J <br />LU Y <br />w o <br />o a <br />0Co <br />N <br />V1 <br />w F- <br />o <br />ZD <br />U C° <br />rn <br />Tw <br />o $ <br />r <br />= ai <br />z� <br />U 0 N <br />Q � o <br />• <br />~O <br />w <br />M <br />o <br />R <br />U_ <br />ZO <br />� <br />Z ON <br />Z0 <br />Q � <br />v <br />wo <br />20 <br />D a <br />cEu <br />I— C <br />X U <br />00 <br />o E <br />No <br />ao <br />p <br />Q <br />& <br />w W <br />K <br />L <br />N CY <br />Z <br />U <br />h <br />m O <br />o, <br />Z <br />N <br />U) <br />m <br />Q <br />Q W <br />20 <br />Z Z <br />U <br />fl- <br />o <br />gZ <br />a <br />m w <br />U� <br />= G <br />~¢ <br />O <br />oZ <br />W <br />F <br />=� <br />F <br />¢o <br />IIIIIIII� <br />coO <br />� <br />5 <br />a x <br />� <br />oo3 <br />°N <br />> d: <br />N <br />W <br />0 <br />.> <br />r. <br />n/ <br />c <br />LL <br />J <br />N <br />^ <br />Q <br />C o <br />w <br />O <br />m <br />IL <br />C <br />N <br />Z N <br />r <br />TLO <br />_ <br />o <br />cM CV <br />E <br />E <br />z° <br />E O02) <br />E <br />cc <br />n <br />U � <br />Q p <br />JOB <br />NO: <br />20-2746 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />