h2 <br />V� <br />a <br />00 <br />49 <br />0 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />NEMA1 <br />2DO AMP <br />MAIN <br />0 <br />200 amp <br />150 amp <br />1pper to lights & outlets <br />1pper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEEDj <br />�,ILfll <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />DEDICATED RECEPTACLE <br />range 2" AFF <br />FOR MICROWAVE RANGE <br />2. All trim plates & devices to be ganged, where <br />p g g possible. <br />HOOD PER SPECS <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />GFI ; GF <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />r ----- <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />1 <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />I <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />FII <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />I <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />3 <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />PL <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />I <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />VIP <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />GFI <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />co <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />FPATIO7 <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />FET-G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />14 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />O <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />F< <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Cl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />ROUGH -IN FOR OPT, CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />VIP <br />GFI <br />DISC. <br />®r- <br />rA <br />IS 0 <br />�:T <br />OPT. <br />REF. <br />KITCHEN <br />I I I I <br />------------- <br />I------ (PGFI <br />DINING ROOM <br />/PENDANT AS <br />/ PER SPECS <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H. <br />VERIFY LOCATION rr IRRIGATION _ _— <br />ELECTRICAL PANEL GFI @ 44" A.F.F. <br />I <br />I <br />I <br />_ I <br />� � I <br />� � I <br />I <br />I <br />� � I <br />\ \ I <br />GFI FOR I <br />GFI @ 44" GAR. DOOR <br />A.F.F. GFI <br />f= I <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OL------------ <br />GFI @ 44" <br />W.H) . 0.F.F. <br />"1 <br />FOYER <br />qpT/ M <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED � ewm. <br />\ <br />FLEX <br />FAMILY ROOM <br />/ TO 2ND <br />� I — <br />zjJ <br />FLR. <br />^x) <br />ROUGH-IN FOR <br />— — OPT. CLG. FAN/ <br />_ — _ — — LIGHT PRE -WIRE <br />I I I I <br />I I I I fill <br />f,[i <br />I I 1 I I <br />.MEN <br />M5��■1 6� <br />GFI <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE:1/4'=1'-0" <br />CD <br />zg <br />Z <br />z <br />Q <br />a <br />U) z <br />(D <br />V^)' <br />4W <br />� w <br />0 LU <br />E <br />~_ <br />cC0 <br />O <br />ElmW <br />{N <br />L Ll OD <br />co OOD <br /><cc0%o <br />Z N o, o <br />z o <br />i c oC <br />O <br />LL N <br />`� <br />r-� <br />W <br />�-a <br />0W� <br />3070. <br />z <br />:9 �� <br />LL Z(ip�Y <br />M m <br />m <br />Q� <br />W C8 <br />N <br />n <br />O U <br />❑❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />1f <br />O <br />Z N <br />0 a�r-pp <br />> U-) ro <br />Z <br />M <br />Q U) 'p to <br />0 <br />< N LL <br />a <br />oC U a <br />Q 000 <br />E <br />Z <br />WJ <br />0 <br />Milli! <br />W <br />Za <br />�z80 <br />z0W <br />z <br />z <br />J <br />a0 <br />0 <br />Q) <br />$ S <br />W <br />L.ri <br />w <br />uj <br />0 <br />-a <br />N <br />O <br />O <br />W <br />O <br />J <br />z <br />�0gg <br />N` <br />Q <br />�j <br />o� <br />aQLuo <br />a <br />d" <br />Z <br />Z <br />^s <br />0 <br />J�--1 <br />Ln <br />W <br />a " <br />z <br />N <br />a <br />Z <br />O <br />Z <br />= <br />ca 0 <br />� <br />00 <br />g <br />SCALE : AS NOTED <br />DATE : 3/16/2018 <br />TECH: M]AM ES <br />VERSION NO. 5mO <br />SHEET NO. <br />4.0 <br />