Laserfiche WebLink
THESE DETAILS ARE GENERIC AND <br />MEANT TO SHOW GENERAL FLASHING <br />AND WATERPROOFING METHODS TO <br />BE USED. <br />^' ^ ") WEATHER <br />✓E BARRIER & <br />1ARILY SECURE <br />WEATHER <br />RESISITIVE <br />BARRIER <br />HEAD FLASHING TIE-IN INSTRUXTIONS: <br />1. Cut, fold up & temporarily secure weat <br />barrier above header to allow for flashing <br />installation <br />2. Self -adhered flashing plus head flashing under <br />weather resistive barrier <br />3. Fold weather resistive barrier back over head <br />flashing and seal with tape <br />SELF -ADHERED FLASHING Scale: NTS <br />FLANGED WINDOW <br />FLASHING INSTALLATION AFTER WEATHER RESISTIVE BARRIER <br />EXTERIOR SHEATHING <br />REFER TO TECHNICAL <br />LETTER ON CHEMICAL <br />COMPATIBILITY <br />SELF -ADHERED FLASHING - <br />DO NOT FLASH OVER <br />BOTTOM NAILING <br />FLANGE <br />NAILING FLANGE <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />rv-�onirvu <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC <br />R703.2.1 AND FBCR 703.7.3 <br />Detail Instructions <br />Refer to the number marked as ## in each detail that corresponds to the <br />numbered items in the list of instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding <br />laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, <br />embedded in the adhesive layer) - for ease of installation and to <br />minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and <br />adhere to substrate using a square piece of flashing material (6" x 6" <br />Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to <br />fit tight to corner <br />8. Mechanically fasten as necessary <br />EXTERIOR <br />SHEATHING <br />WOOD FRAME CONSTR. <br />SELF -ADHERED FLASHIN <br />BY LAPPING DOWN - <br />OVER RIM JOIST AND UP <br />WALL BY 6 IN. <br />WEATHER <br />RESISITIVE <br />BARRIER SEAL TOPS OF JOIE <br />UNDER DECKING <br />ED FLASHING (SEE DETAIL WP07) <br />1� <br />WEATHER RESISTIVE <br />BARRIER <br />DOOR ROUGH OPENING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />i� SELF -ADHERED FLASHING <br />SUBFLOOR <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK - SECTION A <br />EXTERIOR SHEATHING <br />3/4"-1" BEAD OF CONSTR. <br />ADHESIVE TO BE APPLIED UNDER <br />THRESHOLD OF DOOR AND RETURN <br />UP JAMB 6". USE LIQUID NAIL BRAND <br />OR EQUAL WEATHER PROOF CAULKING <br />SECTION -A (SEE DETAIL <br />RIM JOIST <br />INSTALL SELF -ADHERED <br />FLASHING JAMB & HEAD <br />FLASHING, SEE <br />FLANGED WINDOW <br />(SEE DETAIL WP01) <br />SELF -ADHERED FLASHING, <br />EXTEND A MINIMUM 6" <br />VERTICALLY FROM <br />BOTTOM OF <br />THRESHOLD <br />8 2 <br />WINDOW UNIT <br />SLOPE <br />0.3 in: 12.0 in <br />(0.6 cm : 30.5 cm) <br />SELF -ADHERED FLASHII' <br />EXTERIOR <br />CEMT. FIN. <br />BUILDING PAPER <br />WIRE LATH <br />SELF -ADHERED FLASHING <br />CEMT. FINISH SILL/ POTSHELF/ CHIMNEY SHOULDER <br />MECHANICALLY FASTEN IF RUBBERIZED RUBBERIZED ASPHALT <br />NEEDED IN CORNERS ADHESIVE <br />THROUGH SELF -ADHERED ASPHALT ADHESIVE <br />FLASHING -eli r-_onWGDGn CI ecWlnrr_� Ir <br />ON <br />SELF -ADHERED FLASHING <br />rLr��rnrvu <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />4"OR8"CMU <br />(PER SEAT DEPTH) <br />FILL WITH GROUT - <br />SLOPED MUD B <br />VINYL SHOWER PAN <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />8 UNDER DECKING <br />(SEE DETAIL WP07) <br />.E <br />AM <br />SELF-ADHER <br />O <br />1'-4" PER PLAN <br />SHOWER SEAT <br />0 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Z <br />W <br />a <br />d <br />W <br />v <br />W <br />Lu <br />0 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />PLASTER STOP - <br />CONTINUOUS BACKER - <br />ROD & SEALANT <br />A <br />14 <br />0 <br />0 <br />0 <br />0 <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-�(Ground <br />FOUNDATION WEEP SCREED <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />WRAP DP WRB ONTO <br />THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />THIS GAP IS A RESULT OF <br />NATURAL SHRINKAGE. <br />DO NOT SEAL. <br />DRIP SCREED PLASTIC <br />ACCESSORY <br />SOFFIT/CANTILEVER <br />FLASHING REQUIREMENTS <br />R703.1 General. Exterior walls shall provide the building with a weather -resistant exterior wall envelope. The exterior wall envelope shall include <br />flashing as described in Section R703.4. A water -resistive barrier is described as a material behind an exterior wall covering that is intended to <br />resist liquid water that has penetrated behind the exterior covering from further intruding into the exterior wall assembly. An exterior wall covering <br />is described as a material or assembly of materials applied on the exterior side of exterior walls for the purpose of providing a weather -resistive <br />barrier, insulation, or for aesthetics, including but not limited to, veneers, siding, exterior insulation and finish systems, architectural trim and <br />embellishments such as cornices, soffits, and fascias. <br />R703.2 Water -resistive barrier. One layer of No. 15 asphalt felt, free from holes and breaks, complying with ASTM D226 for Type 1 felt or other <br />approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches <br />(152 mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a <br />manner to meet the requirements of the exterior wall envelope as described in Section R703.1. <br />R703.7.3 Water -resistive barriers shall be installed as required in Section R703.2 and, where applied over wood -based sheathing, shall include a <br />Q water -resistive vapor -permeable barrier with a performance at least equivalent to two layers of Grade D paper. The individual layers shall be <br />installed independently such that each layer provides a separate continuous plane and any flashing (installed in accordance with Section R703.4) <br />intended to drain to the water -resistive barrier is directed between the layers. <br />Exception: Where the water -resistive barrier that is applied over wood -based sheathing has a water resistance equal to or greater than <br />that of 60-minute Grade D paper and is separated from the stucco by an intervening, substantially nonwater-absorbing layer or designed <br />drainage space. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall cavity <br />or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. All <br />exterior fenestration products shall be sealed at the juncture with the building wall with a sealant complying with AAMA 800 or ASTM C920 Class <br />25 G d NS t f nt d t t' ASTM C1281 AAMA 812 th d t d d t f th <br />SCORED __LL� <br />ra a or grea er or proper lol expansion an con rac Ion, or o er approve s an ar as approprla a or e <br />RELEASE PAPER type of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply with AAMA 714. The flashing shall extend to the surface <br />(BEFORE FOLDING, SCORE of the exterior wall finish. Approved corrosion resistant flashings shall be installed at the following locations: <br />RELEASEDHSIVEASSHOWN) APER TO SE 1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish <br />or to the water -resistive barrier complying with Section 703.2 for subsequent drainage. Mechanically attached flexible flashings shall <br />comply with AAMA 712. Flashing at exterior window and door openings shall be installed in accordance with one or more of the following: <br />1.1 The fenestration manufacturer's installation and flashing instructions, or for applications not addressed in the fenestration <br />manufacturer's instructions, in accordance with the flashing manufacturer's instructions. Where flashing instructions or details <br />are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or <br />sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water resistive barrier for subsequent <br />2 drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides. <br />5 1.2. In accordance with the flashing design or method of a registered design professional. <br />4 1.3. In accordance with other approved methods. <br />1.4 In accordance with FMA/AAMA 100, FMA/ AAMA 200, FMA/WDMA 250, FMA/AAMA/ WDMA 300 or FMA/AAMA/WDMA 400. <br />6 2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco <br />7 copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />' 4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />LEGEND <br />SELF ADHERED FLASHING (SAF) ti o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGIASS �17 <br />STRUCTURAL FRAMING <br />STRUCTURAL SHEATHING <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />i BOND BREAK WRB <br />,--SF LATH <br />ail <br />I <br />'ER STOP A <br />NUOUS BACKER ROD <br />LANT <br />NTITIOUS FINISH <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />THESE DETAILS ARE GENERIC AND MEANT TO SHOW GENERAL <br />FLASHING AND WATERPROOFING METHODS TO BE USED. <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain <br />Bottom of <br />Weep Screed <br />1 1/2"to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />i� <br />P <br />0 <br />CV <br />ZOR <br />M <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building <br />Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing <br />pages bearing <br />Engineers signature and seal. <br />M <br />W <br />Q <br />E Co <br />o E N- ampp <br />O O O p, co N_ ik <br />®O <br />I• N C <br />�`'� N ti N <br />Un N LL <br />� ao <br />U) <br />+�-M�-ON <br />5 <br />J W <br />LL LL a <br />uj C, <br />W <br />"ILauLouf <br />Z <br />°' <br />0 W o <br />In <br />aJ1i o <br />m m C) <br />W <br />moor° <br />�E°'O' <br />_oa <br />ILyW <br />qN Q C) Z <br />U O0 Z)2 <br />a <br />U <br />❑.7❑ <br />W <br />N <br />z Q <br />D <br />� QQN <br />Z O Q <br />� <br />Q <br />J th <br />O <br />d <br />th <br />z D <br />(D o <br />Cr= Y <br />f>3 w o <br />o Q <br />N <br />�LO <br />WJ <br />c o <br />� <br />� o <br />� <br />U 0° <br />m <br />WJ _ <br />r- m E <br />o <br />40 <br />= N <br />¢°M <br />4m <br />ti <br />co <br />co <br />0_3 <br />w <br />W <br />Z <br />m <br />o g <br />< <br />Z <br />J <br />Ll_ <br />Q E <br />O <br />E <br />z <br />zo <br />oo <br />z <br />>S <br />< � <br />Za <br />❑a <br />.- M <br />� <br />U° <br />CIL <br />CD E <br />o� <br />_ <br />0� <br />z <br />N <br />i <br />w 00 <br />¢ O <br />K � <br />m 0 <br />tp <br />C/) <br />0 z <br />or <br />U <br />" <br />O <br />Z <br />Z(n <br />Cn J <br />am <br />2W <br />2z <br />N <br />0< <br />ao <br />LL <br />Ez <br />oLL Z <br />=3 <br />V; <br />WJ <br />� <br />o it <br />zIa <br />a <br />O <br />c� 3 <br />L <br />J <br />i� <br />L <br />f0 <br />> <br />ca <br />N <br />O <br />m <br />^, <br />C <br />p <br />T- <br />. _ <br />Z <br />1-- <br />N <br />= <br />o <br />LO o <br />r <br />Ev, <br />TLn <br />M M <br />° <br />m <br />D N <br />vi r <br />Z <br />Z <br />E O <br />E <br />t0 <br />a <br />o <br />U <br />' m <br />Q p <br />aa)) <br />_J <br />JOB <br />NO: <br />20-1789 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />