3059 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3059 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:07:00 PM
Creation date
2/19/2025 8:51:01 AM
Metadata
Fields
Template:
Building Plans
Street #
3059
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
131
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station cc alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />�@wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />jR <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PB PUSH BUTTON SWITCH (OPTIONAL) <br />F[jBD <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />TT <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />Q <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />NMI <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />G J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G F J <br />OPT. CEILING FAN <br />GD <br />(1) PHONE LINE, (1) DATA PORT <br />200A INDOOR PANEL <br />CENTER <br />NEMA 1 <br />200 AMP <br />METER <br />MA0IN <br />200 amp <br />150 amp <br />Disconnect <br />POWER CO. FEED--_- <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />#14 copper to lights & outlets <br />#12 copper to 20 amp ckts <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />or 410 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />FC...." ...... <br />SYSTEM <br />UPPER ELECTRICAL PLAN <br />SCALE: l4"=1'-0" <br />uZti <br />0 <br />cat <br />c+ <br />00 <br />M <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017.Flodda <br />Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />NE <br />Q <br />8 <br />OD <br />��pp <br />N N 3k <br />ci <br />p OF- O C <br />M CV N <br />u N J <br />LL <br />ooCO <br />4,0 <br />it Lu <br />a <br />N M 5 <br />aimu SZ <br />LL LL In <br />as <br />Z <br />ZZ` o <br />W <br />@WC <br />'Roam <br />W00 <br />IM <br />m�Q <br />W <br />IL <br />- E rn <br />J o a <br />Z <br />a <br />NQco Z <br />a 0 <br />U !- J <br />z <br />° 0 <br />❑O❑ <br />W <br />CD <br />0 0 <br />QQN <br />Z O Q <br />a <br />J M <br />d N <br />M <br />z <br />!!nn o <br />�N <br />V LL <br />U <br />r) a <br />0 <br />V) <br />,., F- <br />= E <br />N <br />M <br />O <br />ws <br />iN <br />t— <br />U m <br />W m <br />O <br />U o " <br />Q Y <br />CW � <br />a <br />sm <br />ti <br />co <br />c', <br />y <br />w <br />Z <br />M <br />o <br />LL <br />E <br />E <br />a <br />�� <br />>� <br />e <br />0 <br />H <br />O <br />0 <br />O¢ <br />wo <br />U0 <br />0a <br />CV to <br />az <br />o <br />Q <br />dz <br />¢ <br />L <br />to <br />C <br />_ C <br />Z <br />0y <br />�m <br />m 0 <br />of <br />>Z <br />J <br />0. <br />2 z <br />ul <br />-) <br />O ' <br />O <br />U <br />W <br />o <br />�Z <br />Z W <br />�� <br />� <br />;o <br />cfl <br />o� <br />ZIQ <br />a <br />O <br />O 7 <br />J <br />L0 <br />> L6 <br />�i <br />rn <br />m <br />m <br />� <br />nL <br />W <br />' <br />L.n <br />c° <br />J <br />N <br />^ <br />Q <br />m <br />CLO <br />C� <br />o <br />Q <br />.� <br />Z O <br />T <br />N <br />= <br />LO o <br />r <br />ai <br />Q <br />th cM <br />o <br />.= N <br />T <br />z <br />Z <br />_ <br />E Q <br />to <br />m <br />n <br />U <br />Q p <br />JOB <br />NO: <br />20-1789 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.1 <br />