My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3060 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3060 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:20:14 PM
Creation date
2/19/2025 8:51:15 AM
Metadata
Fields
Template:
Building Plans
Street #
3060
Location
Nubbin Ridge Ln
Contractor
Lennar Homes LLC
Building Plans - Permit #
130
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
22 <br />D1 <br />22 <br />D1 <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS REQ'D <br />@ END OF LANDING <br />BELOW HDR. BEAM. <br />x <br />STANDARD (3) 2x12 <br />0 <br />3 <br />STRINGERS w/ <br />SIMPSON A35/USP <br />o <br />MP34 CLIP TO <br />Z <br />Cr <br />FLOOR SYSTEM OR <br />LANDING FRAMING <br />o <br />(2) 2x HDR. <br />g <br />REQ'D @ END OF <br />w <br />LANDING FOR <br />LU <br />STRINGERS TO <br />CONNECT TO <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @ LANDING <br />@ 16"O.C. w/ SIMPSON A35/USP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MASONRY <br />WALL) CONTINUOUS LEDGER <br />w/ (3) 16d NAILS @ 16" O.C. MAX. <br />TO EA. STUD. ((2) 1/4"X3 1/2" <br />TITENS @ 16" O.C. MAX. FOR <br />MASONRY WALL) <br />riLa <br />0 <br />T <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. 9'-0" MAX LANDING LENGTH <br />29'-0" <br />2'-6" 26'-6" <br />01 <br />TYP @ 2 STORY 3 EXT. WALL TO BE 3 <br />D22x4 #2 SPF @ 16" D2 <br />O <br />2 <br />SH O.C. U.N.O. <br />q <br />EGRESS <br />I <br />I <br />H1 <br />D2 <br />e I <br />ti <br />I <br />I <br />I <br />I <br />li <br />m <br />00 <br />1 co <br />Ica <br />U 1 <br />oa I <br />00 ' N <br />00 N <br />I °C <br />I <br />is <br />iv <br />1 <br />12'-4" <br />to <br />1 <br />12'-4"I co <br />2,-4, <br />1 12'4° <br />I I <br />C/) <br />W <br />cc <br />BEDRO M 2 <br />4SH12"DEEP °° <br />B IDROOM 3 W <br />8'-0" FLAT CLG. <br />LINEN <br />8'-0" FLAT CLG. <br />CARPET iv <br />2468 B.F. <br />CARPET <br />I <br />74" 5'-0" <br />4'-2" 3'4" <br />8'-8" <br />2668 2668 <br />I <br />I R&S <br />r"'• <br />FIB <br />C8 <br />GLASS ro�� O <br />�' <br />W. I <br />Cl) <br />SURROUND <br />QJ <br />o2m H <br />T I <br />I 8'-0" FLAT CLG. <br />"C" <br />10 <br />I 1 CARPET <br />m it <br />1 12 _ _ _ _ <br />O 2668 <br />��,,�Oo <br />-orN <br />13 <br />- 1, 5 0 -- <br />- - -- <br />- 16 <br />-- -- <br />N� q <br />46 XIv0\ I <br />MI Q \ 1 <br />BED OOM 4 <br />8-0 FLAT CLG. <br />iyARPET <br />6 <br />- <br />5 <br />-- <br />TB <br />4 <br />-- <br />3 <br />I I <br />z <br />W <br />2 <br />- - <br />J <br />W <br />+42" HALF <br />WALL I <br />o <br />o <br />�I <br />C7 <br />C7 <br />O <br />W <br />X1X I <br />"LL <br />4'4 <br />T-4" <br />5 <br />12-0" <br />LOFT <br />;. <br />V-0" FLAT CL <br />� '� <br />ao <br />CARPET <br />N <br />I <br />co <br />2'-8" <br />13'-8" <br />`O <br />I <br />I <br />I <br />I <br />I W w <br />� <br />Ir <br />Crw <br />U) <br />cn 1 <br />00 <br />00 <br />1 <br />I <br />oQ <br />00 <br />I <br />ul) <br />BE ROOM 5 <br />j <br />8'- " FLAT CLG. <br />I <br />I <br />I <br />I <br />CARPET <br />I <br />25- <br />H2 <br />O D2 <br />3H <br />A 3 J 3 <br />D2 S6 D2 <br />TYP @ 2 STORY <br />6'-7" <br />22'-11" <br />29'-6" <br />1 TYP @ <br />D2 CORNERS <br />U.N.O. <br />0 <br />TYP @ 2 <br />STORY <br />J <br />S6 <br />= I <br />OI <br />1 <br />I 4 <br />I <br />OH1 D2 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />_O <br />LO <br />THRUST BLOCK SECURED TO SLAB w/ <br />1/4"X3 1/2" TAPCONS @ 16" O.C. <br />STAIR SECTION <br />SCALE: 1 /7=1'4' <br />SIN <br />�N <br />CONT. HANDRAIL <br />RETURN TO <br />WALL DETAIL(:A) SCALE: NTS <br />STAIR CALCUTIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 9/16" <br />10" TREADS wl 1" NOSING <br />Stairway construction shall conform to the FBC Residential 6th Edition (2017) sections R311.7, R312 <br />and R302.7. <br />Riser height: <br />The riser height shall be not more than 73/4 inches. The riser shall be measured vertically between leading <br />edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by <br />more than 3/8 inch. <br />Tread depth: <br />The tread depth shall be not less than 10 inches. The tread depth shall be measured horizontally between the <br />vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The <br />greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. <br />Winders: <br />Winder treads shall have a tread depth of not less than 10 inches measured between the vertical planes of the <br />foremost projection of adjacent treads at the intersections with the walkline. Winder treads shall have a tread <br />depth of not less than 6 inches at any point within the clear width of the stair. <br />Nosings: <br />The radius of curvature at the nosing shall be not greater than 9/16 inch. A nosing projection not less than 3/4 <br />inch and not more than 11/4 inches shall be provided on stairways with solid risers. The greatest nosing <br />projection shall not exceed the smallest nosing projection by more than 3/8 inch between two stories, including <br />the nosing at the level of floors and landings. Beveling of nosings shall not exceed 1/2 inch. <br />Handrails: <br />Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more <br />risers. Handrail height measured vertically from the sloped plane adjoining the tread nosing, or finish surface of <br />ramp slope, shall be not less than 34 inches and not more than 38 inches. Handrails for stairways shall be <br />continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly <br />above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety <br />terminals. Handrails adjacent to a wall shall have a space of not less than 11/2 inches between the wall and the <br />handrails. <br />Grip -size: <br />Handrails with a circular cross section shall have an outside diameter of not less than 11/4 inches and not greater <br />than 2 inches or provide equivalent grasp -ability in compliance with Section R311.7.8.3. <br />Guards: <br />Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located <br />more than 30 inches measured vertically to the floor or grade below at any point within 24 inches horizontally to <br />the edge of the open side. Required guards at open -sided walking surfaces, including stairs, porches, balconies <br />or landings, shall be not less than 36 inches in height as measured vertically above the adjacent walking surface <br />or the line connecting the leading edges of the treads. Required guards shall not have openings from the walking <br />surface to the required guard height that allow passage of a sphere 4 inches in diameter. <br />Under -stair protection: <br />Enclosed accessible space under stairs shall have walls, under -stair surface and any soffits protected on the <br />enclosed side with 1/2-inch gypsum board. <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) - 1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) -1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) -1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />"* SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />140C <br />EXTERIOR 2ND FLOOR <br />BEARING WALL SCHEDULE <br />HEIGHT <br />STUD <br />SPECIES <br />SPACING <br />SPF #2 <br />8'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />9'-0" <br />2x4 <br />SYP #2 <br />16" O.C. <br />SPF #2 <br />>9'-0" <br />2x6 <br />SYP #2 <br />16" O.C. <br />' IF WITHIN 4FT OF END ZONE, USE DOUBLE STUDS AT <br />CORNERS <br />" WALL SHEATHING 15/32" EXPOSURE 1 OR EQUIVALENT " <br />SEE C/S6 WALL SCHEDULE <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20X26 <br />18JX25} <br />S.H. <br />13 <br />20X38J <br />18JX37J <br />S.H. <br />14 <br />20 X 501 <br />18 J X 50 <br />S.H. <br />15 <br />20 X 63 <br />18 4 X 62 1 <br />S.H. <br />16 <br />20X72 <br />184X71} <br />S.H. <br />1 H2 <br />27 1/4 X 26 <br />26 X 25 } <br />S.H. <br />1H3 <br />271/4X38) <br />26x371 <br />S.H. <br />1 H4 <br />27 J X 50 J <br />26 x 50 <br />S.H. <br />11-15 <br />27JX63 <br />26X621/2 <br />S.H. <br />1H6 <br />27JX72 <br />26X711/2 <br />S.H. <br />22 <br />37 X 26 <br />36 X 25 112 <br />S.H. <br />23 <br />37 J X 381 <br />36 J X 37 3/4 <br />S.H. <br />24 <br />37 J X 501 <br />36 � X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37JX72 <br />364X711/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 } WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 i <br />S.H. <br />33 <br />54 X 381J <br />52 } X 37 J <br />S.H. <br />34 <br />54 X 50 J <br />52 } X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 J X 62 i <br />S.H. <br />36 <br />54 X 72 <br />52 } X 71 J <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. . <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic, crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above flr. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />OA <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />DE <br />+26.6 / -28.0 <br />O <br />+26.6 / -32.2 <br />GO <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />711111111111111111 MR. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" <br />FIRST FLOOR LIVING 1793 <br />AREA <br />SECOND FLOOR LIVING 1103 <br />AREA <br />LIVING TOTAL 2896 <br />GARAGE 437 <br />FRONT ENTRY 26 <br />TOTAL AREA 3359 <br />INSULATION REQ. <br />LOCATION <br />R-VALUE / TYPE <br />EXT CONC WALL <br />R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 <br />R-11/R-13 KRAFT FACED <br />SECOND <br />FLOOR <br />PLAN <br />- Al <br />EXT FRAME 2 x 6 <br />CONDITIONED CEILING <br />R-19 KRAFT FACED <br />R-30 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />1/ I GARAGE SEPARATION I R-11/R-13 KRAFT FACED <br />SCALE: J4'=1'-0" (GARAGE / LIVING) <br />0 <br />0 <br />0 <br />i <br />r/p��i <br />\`�\!\EtttlfiEYt <br />" <br />/ <br />ti <br />'' •- <br />• V�<� �� <br />`14 <br />CC <br />Q <br />G <br />�. <br />s <br />F �. <br />aFF3S�Oa <br />f <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Resldential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />W <br />F <br />U(cor <br />i-O <br />Co <br />k <br />O -NO O ps <br />0 <br />Lo <br />J <br />mMC N LL <br />1'� *k <br />_J <br />7 LL N U.LL a <br />S <br />e' <br />Z <br />0 <br />aicii aa� <br />> c <br />- C, <br />V 6)I <br />2 8 X m <br />0: <br />W <br />a C N oo 0 <br />more <br />W <br />Z <br />2 E CP 6 a <br />J <br />E N 0 y <br />2 <br />N Q M Z U J <br />�� <br />Z <br />❑❑❑ <br />W <br />z � <br />J <br />a <br />fn <br />R <br />z 9 <br />o <br />Q) <br />U <br />�--r <br />f0 <br />'v <br />cn 1 <br />w o <br />n <br />� a <br />0 <br />c <br />V) <br />�r <br />0 <br />U & <br />W c <br />O 8 <br />I <br />z�.. <br />= <br />s <br />Q�� <br />s <br />O <br />w <br />MZ <br />LL <br />o <br />a <br />CL o <br />E rJ <br />w° <br />� <br />_• <br />oa <br />I- ro <br />_ CL <br />1U <br />U <br />SO <br />Z <br />O E <br />N <br />0 <br />�o <br />¢� <br />w� <br />ro <br />N C <br />o <br />0 <br />zLL <br />Z <br />N J <br />�b <br />ZK <br />� 3 <br /><w <br />S� <br />ZZ <br />58 <br />W <br />U <br />w� <br />a <br />mw <br />o <br />CO <br />� <br />0. <br />zla <br />a x <br />p <br />o 3 <br />T <br />2 <br />Cy <br />^, <br />W <br />m <br />� <br />LILI <br />Z <br />�> <br />g <br />to <br />Q <br />C <br />o <br />O <br />m <br />Z <br />� <br />C <br />? N <br />�� <br />Z o <br />T <br />N <br />E <br />CV <br />`y ") <br />Z <br />Z <br />E 0 <br />to <br />c <br />n- <br />U _J <br />Q p <br />c <br />JOB <br />NO: <br />20-1787 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1.1 <br />r <br />
The URL can be used to link to this page
Your browser does not support the video tag.