Laserfiche WebLink
�loo <br />c <br />I <br />1" x 4" SMOOTH <br />TEXTURED <br />TRIM / BAND <br />6" FASCIA <br />(TYP) <br />T.O.P. <br />HDR HGT. <br />_---- <br />EXTERIOR <br />PLASTER ON <br />FRAME <br />2nd FIN. FLR. <br />—RED ----- <br />T.O.M. <br />HDR HGT. <br />DECO <br />CORBEL <br />TEXTURED <br />CEMENTITIOUS <br />FINISH ON C.M.U. <br />FIN FLR <br />12 <br />5� <br />8'-0" RIDGE VENT <br />I IN <br />SHINGLE OR TILE ROOF PER <br />COMMUNITY SPECS - INSTALLED <br />PER MANUFACTURERS <br />SPECIFICATIONS —� <br />-------------------- <br />4' RIDGE VENT <br />12 <br />SHINGLE OR TILE ROOF PER <br />COMMUNITY SPECS - INSTALLED <br />PER MANUFACTURERS <br />SPECIFICATIONS <br />1'-0" <br />1" x 12" SMOOTH <br />TEXTURED <br />TRIM / BAND <br />1" X 8" SIMULATED <br />WOOD FINISH <br />FRONT ELEVATION - Al <br />12' RIDGE VENT <br />N 2" <br />io <br />1 GABLE END VENT <br />SCALE: 3/4"=1'-0" <br />OR <br />1" <br />2 COLUMN DETAIL <br />SCALE: 3/4"=T-0" <br />T.O.P. <br />HDR HGT. <br />1'-0" <br />- EXTERIOR <br />PLASTER <br />ON FRAME <br />—100 <br />CV ' <br />co <br />2nd FIN. FLR <br />T.O.M. <br />HDR HGT. <br />ti <br />FIN FLR <br />N <br />LEFT ELEVATION - Al <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />a <br />a <br />CO <br />a <br />,\\1�\1\\\�1! <br />W <br />w-. .••may <br />S Iro cam• <br />N <br />�• CO C!� <br />]� F l- <br />'9O F E S S\" <br />� nrmlif,�� <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential Bth Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />61 <br />f <br />c 8 N <br />epJp <br />Lo <br />N ' CN ` � � CND LL <br />*k <br />a <br />.5 -, _J L� <br />U. <br />M LL LL CL <br />N <br />y W {y� <br />IL <br />N lL ii 2 <br />a a� 0 <br />Z <br />0 <br />maN m <br />0 r, <br />W <br />W <br />d � <br />MEq'rn Jpa <br />Z <br />CLW <br />�c�o �Gti <br />N a M Z U ♦! J <br />z <br />°01 1 <br />Z <br />Z p d <br />Q Y <br />N <br />v <br />-3 <br />z 's <br />0 <br />(1)4-J <br />u <br />uJ <br />Wo <br />to <br />W <br />c ~ <br />to <br />YZ <br />a® <br />~ = <br />U_ <br />0 <br />_ <br />ta <br />Q.4 <br />ti <br />O <br />V5 <br />w <br />_J <br />s <br />Zo <br />3 <br />>9 <br />ze <br />z <br />O <br />°�zZ <br />N <br />.tip. L <br />QO <br />mi <br />� c <br />z <br />� J <br />3 <br />�m <br />ill <br />0 <br />ga <br />U <br />a z <br />W <br />U <br />J <br />ilaTc�i <br />3 <br />2 T <br />2 <br />>M <br />d <br />W <br />0 <br />> <br />z <br />d" <br />■y <br />N <br />I� <br />W <br />^ <br />C <br />C7 <br />O <br />CO <br />z <br />0 <br />z C <br />CN <br />= <br />O N <br />r <br />E <br />N <br />M M <br />Z <br />CD <br />C <br />LD <br />E <br />C <br />JOB <br />NO: <br />20-1787 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.1 <br />