Laserfiche WebLink
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />11. The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with verttcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load / ■ 0 <br />Safe vertical load Safe horizontal load `— <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE—CRETE, QUALITY, LOTTS <br />8F441B/1T8F401B/1T 8RF40OB/lT 8F321B/lT <br />N/FORM & GROUT SOLID <br />:�• - LL <br />(V Q <br />0 r tt.1 <br />#5 BAR CONT. <br />8F12-1 B/1 T <br />O <br />Y' LINTEL DETAIL <br />SCALE = N.T.S. <br />Owl <br />F = FILLED WITH <br />GROUT / U <br />= UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />D <br />8F16— <br />B/1T <br />U <br />tNOMINAL. <br />QUANTITY OF <br />u� <br />WIDTH <br />#5 REBAR AT <br />TOP <br />NOMINAL - <br />HEIGHT <br />MATERIALS <br />cTf prrecasf�nials = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3, grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5REBAR <br />IN. <br />AT TOP <br />(1) REQ'D <br />CLEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° <br />° o ° <br />° <br />d <br />.M.U. <br />#5 REBAR AT TOP <br />4 <br />a <br />D <br />° ° ° <br />° <br />MIN. (1) REQ'D <br />1-1/2" CLEAR <br />° <br />d <br />GROUT <br />° <br />J= <br />Q L <br />U) U <br />4 <br />C.M.U. <br />° <br />5REBARAT <br />H <br />=-m,j <br />4 - <br />° <br />BOTTOM OF <br />a U) z � <br />o <br />LINTEL CAVITY <br />o V 0 m U) <br />it O <br />//\ <br />\ `0 \� <br />-BOTTOM <br />o Cd Z <br />REINFORCING <br />¢ ¢ C7 <br />LL <br />_ <br />7-5/8"ACTUAL <br />PROVIDED IN <br />LINTEL <br />Z O W N <br />¢ _' Ci 3- <br />(0. <br />D D <br />�o �o <br />#5 REBAR AT BOTTC <br />AS INDICATED <br />NOMINAL WIDTH <br />(VARIES) <br />U)in a a0 <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />5'-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: r4"=1'-0" <br />r <br />Q <br />0 <br />0 <br />s••t <br />`,,.• '. <br />yam' <br />0F�S0\0\ <br />•�\ <br />t<fPP3I! sS1"!'!\��`ti <br />To the best of the Engineer's knowledge, Information and belief, <br />the structural plans and specifications contained within These <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />MM 9) <br />Q <br />v V Co O CoF <br />0 <br />,T <br />O O 0) (c, N <br />0 <br />(0V <br />M N N LN J <br />N m <br />0) Lu <br />i» <br />7 LL LL lJL <br />aimiiW1 °'a� <br />Z <br />13a <br />-0Crn Zo <br />f: <br />at o K m O <br />m <br />'Ca o � <br />Earn X 0 a <br />z <br />ILW <br />rr<N� Ln <br />a coZ <br />QOIL� <br />Z <br />N H J <br />U <br />�U ❑❑❑ <br />W <br />N O <br />� o <br />_ 0 <br />� N <br />z Q <br />Z R Q <br />N <br />E3d <br />M <br />Z � <br />o <br />W <br />� LL <br />13 <br />°O <br />cn 0 <br />w o <br />2 <br />tJl <br />�N <br />— m <br />w F- <br />c o <br />� <br />o <br />r- <br />U m <br />m <br />w �+ <br />O <br />= <br />U o <br />go <br />m <br />r• <br />O <br />M <br />¢ <br />w <br />Z <br />Cl) <br />Zo <br />J <br />U_ <br />E <br />W <br />� <br />} <br />�® <br />O <br />E <br />wo <br />� <br />oa <br />U01 <br />O F <br />_ <br />° <br />0 <br />O E <br />N <br />ao <br />Q <br />Z <br />¢W <br />W <br />L <br />C <br />_ <br />¢0 <br />U <br />.9 <br />2 <br />m o <br />o <br />Z, <br />ZFW <br />Qi <br />J <br />m <br />7 <br />Q W <br />sW <br />on <br />Zz <br />go <br />W <br />Q <br />V <br />ado <br />a <br />mw <br />Z <br />m <br />w <br />�~ <br />~� <br />(=_7 �- <br />o <br />t0 <br />ZI¢ <br />>o <br />a x <br />�U 3 <br />0 <br />�M <br />= <br />a) <br />V <br />■ _ <br />c <br />c� <br />CV <br />^ <br />i <br />O <br />0- <br />0 <br />m <br />NN <br />LL <br />O <br />V , <br />�.1�. <br />V <br />■� <br />z NO <br />LO <br />ai <br />00 <br />M <br />j <br />CM <br />o <br />Z <br />Z <br />C <br />E O <br />E <br />a <br />M <br />C <br />t00 <br />a <br />0 <br />0 J <br />a is <br />Q p <br />aa)) <br />J <br />JOB <br />NO: <br />20-1788 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />8 <br />