My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3071 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3071 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:34:23 PM
Creation date
2/19/2025 8:51:41 AM
Metadata
Fields
Template:
Building Plans
Street #
3071
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
135
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ATTIC VENTILATION CALCULATIONS - Al (TRA) <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />11150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />SQ. IN. of <br />of vented <br />IN. of <br />of <br />ventilation to <br />SQ. IN. of <br />SQ. IN. of <br />Ventilators. <br />ventilation <br />soffit <br />ventilation <br />vented <br />be provided <br />Ventilation <br />Ventilation <br />(See Elev ) <br />required <br />needed <br />required <br />soffit <br />by upper <br />needed <br />ventilators <br />Main <br />29.00000 <br />1.000000 <br />Floor <br />2373 <br />2278 <br />325 <br />1139 <br />81 <br />570 <br />0 <br />573.0 <br />435.0 <br />138.0 <br />(Zone 1) <br />' NOTE' <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 6th ED. RESIDENTIAL. <br />0 <br />ROOF PLAN - ELEV-Al <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated. Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN* <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN, OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SO. FT. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br />O <br />FED E� <br />�� <br />rr�A <br />.a•'�����t���iltttf�rtiF <br />Owl <br />® I- a <br />` <br />t <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />ON <br />,F° <br />` <br />O co b <br />O O O m <br />N c0 r- <br />Cfl N <br />M N r N <br />J <br />0000 tL <br />C <br />�M0)�NO <br />3 ry N <br />J � UJ <br />LL LL a. <br />a <br />uj Cl) <br />�c� <br />W co <br />aa� <br />031 Z <br />pN0, <br />0 <br />mo_ <br />m m O <br />W <br />W <br />2 E 0 rn <br />o a <br />Z <br />LLa05 <br />v@Nd <br />NQMQ <br />i1� <br />VZ <br />�0 <br />Ci I— <br />❑�❑ <br />MOM W <br />Z N S <br />z <br />� o <br />N <br />U) /� <br />t! / <br />_ M <br />Z <br />-J[ VJ <br />f V LJJ p <br />o a <br />•O — <br />Ln <br />Ln <br />m <br />w � <br />c E <br />® <br />'-- <br />U 00 <br />w it <br />E <br />0 3 <br />I <br />=> <br />= <br />0 <br />4m <br />r` <br />o <br />L� <br />M <br />M <br />z � <br />U <br />Z <br />Z <br />Q <br />J <br />U_ <br />I? E <br />o <br />ti <br />zo <br />�� <br />�z <br />yo <br /><s <br />Z® <br />❑a <br />tT (O <br />— <br />X <br />a8 <br />00 <br />O <br />O� <br />c8 E <br />CN <br />wa <br />a Z <br />i <br />(� <br />- <br />Y <br />U <br />O <br />O ¢ <br />Z <br />Z <br />N <br />"m <br />Qw <br />Cn <br />o <br />5� <br />s? <br />LL¢ <br />¢ o <br />a <br />Nw <br />= <br />f�) <br />N <br />r— <br />= <br />Y <br />C:) <br />UJ <br />za <br />O <br />a� <br />°3 <br />C `' , <br />O <br />T <br />(y� <br />Q1 <br />rn <br />W <br />cc <br />D <br />■> <br />V <br />� <br />N <br />� <br />�., <br />J <br />0 <br />o <br />/I1 m <br />•� <br />�O <br />zLO <br />T <br />ui <br />0) <br />CD 00 <br />ca <br />� IN <br />co ` <br />�; cy <br />o <br />Z <br />z <br />E 0 <br />N <br />N <br />m <br />Ll <br />U J <br />Q <br />C <br />J <br />JOB <br />NO: <br />20-1788 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />5 <br />