My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3078 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3078 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 2:45:05 PM
Creation date
2/19/2025 8:51:58 AM
Metadata
Fields
Template:
Building Plans
Street #
3078
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
22767
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY <br />BON <br />TERMINATIOI' <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />opperto lights & outlets <br />opper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />I Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance With R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shalt be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying With UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or Window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PqF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />IGFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />Fiwc <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />F_o <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />tOt <br />r <br />EXHAUST FAN/LIGHT COMBINATION <br />0 <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />HEN <br />PUSH BUTTON SWITCH (OPTIONAL) <br />I0 <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />®2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />D9 <br />ELECTRIC METER <br />_a <br />ELECTRIC PANEL <br />l <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />VERIFY METER <br />LOCATION WITH <br />BUILDER <br />' n <br />� <br />VERIFY LOCATION <br />" IRRIGATION <br />ELECTRICAL PANEL <br />F GFI @ 44" A.F.F. _ 4—t <br />OPT. <br />`.� FAMILY kM GF - D. <br />- <br />--W <br />\ \ <br />2 CAR GARAGEROUGH-INFOROPT. <br />tG <br />CLG. FAN/ — — — — — <br />PRE -WIRE -tFI <br />_LIGHT <br />\ �' Hj�OPT. <br />\ <br />0 <br />1 GARAGET-4)" <br />@ <br />w wZi U <br />\ (D CL <br />1 I I <br />1 DOORmaw <br />" <br />GFI <br />I <br />A.F.F. <br />\ a W <br />�I <br />FI <br />1 )GGIF <br />( I \` �/ <br />I I I <br />U.C. SWITCH — <br />• I <br />I 1 I <br />I I I <br />FOR DISPOSAL I <br />I <br />I I I <br />I I I <br />I II <br />Ij <br />I I I <br />I <br />1) <br />I I I <br />1 <br />ENTRY <br />I <br />�i F I <br />I <br />OGFr <br />I I I <br />. <br />I Ilr----I <br />PATIO <br />c� I <br />W.H. <br />GFI@44" <br />A.F.F. <br />L — — — — — — — — — — — — 11 <br />CAFE I III D.W.I <br />I <br />________ <br />1 GFI <br />DEDICATED RECEPTACLE <br />— <br />3 3 <br />T3") <br />\ FOR MICROWAVE RANGE <br />\ <br />I I <br />\ HOOD PER SPECS <br />FOYER <br />c i <br />OP <br />I ` <br />WP I I <br />GFI I , <br />_ <br />p <br />I I <br />GFI I I <br />AIN I C.M <br />db <br />----- <br />DISC. 4 <br />WP <br />GFI <br />AC PAD <br />N'�l <br />W. <br />OWNER' <br />SUITE - <br />I ROUGH -IN FOR <br />1 OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />1 <br />---- W.I.C. <br />I— <br />I <br />I <br />RECEPT', <br />FOR I <br />ALARM I <br />QVQTCIIA <br />O•• <br />S. <br />BEDROOM 3\ <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />2 <br />C.M <br />VP <br />BEDROOM 2 <br />ROUGH -IN FOR <br />\\ OPT. CLG. FAN/ <br />\\ LIGHT PRE-WIR <br />ELECTRICAL PLAN — ELEV—Bal <br />SCALE: %4 "=1'-0" <br />0 <br />0 <br />N <br />N <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Rodda Building Code - <br />Residential 6th Edition. Engineers signature <br />and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />_ <br />V <br />�0n <br />J <br />m #m OD LL <br />tl! <br />j'L <br />J <br />aa <br />tLLL <br />Q <br />U.' <br />M <br />l0 PiL <br />W y j <br />Q d 0 <br />Z <br />Dy� <br />0�° <br />X <br />= to <br />co m oq o <br />LIL z <br />rn N <br />NQ�Z <br />O O <br />U <br />Z <br />°d <br />F- J <br />❑ODD <br />W <br />Z � M <br />z g <br />J <br />to <br />M <br />V Ll <br />�U <br />N <br />< <br />0 <br />W <br />IN <br />V) <br />c E <br />U m <br />& <br />~� <br />0 <br />U � <br />�3 <br />• <br />—o <br />Q <br />g <br />cD <br />Mi <br />M <br />W z <br />E <br />o <br />z <br />go <br />Q <br />f3 � <br />m H <br />�z8 <br />$ <br />z® <br />pa <br />@g <br />� <br />C) E <br />X U <br />a� <br />o <br />o <br />�z <br />N <br />.o <br />�� <br />tp <br />C <br />U <br />O <br />Z <br />J <br />t) <br />3 <br />a a° <br />W <br />o <br />gz <br />o <br />W>i <br />n <br />g <br />a z <br />Dw <br />�1z <br />z <br />Uja <br />>2 <br />COUj <br />A. <br />o f <br />�33 <br />0 <br />�M <br />= <br />�CV) <br />m <br />^, <br />W <br />� <br />c� <br />\ <br />.= <br />L0 <br />N <br />co <br />J <br />O <br />T� <br />O <br />Y <br />Lo <br />T <br />Z <br />N <br />&.1 <br />L0 <br />EE_ <br />0 <br />Z <br />c <br />E 0 <br />rn <br />L <br />ai <br />a <br />to � <br />'0 <br />o <br />JOB <br />NO: <br />20-1129 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.