Laserfiche WebLink
GENERAL INSTALLATION NOTES <br />1. Provide full mortar head and bed joints. <br />2. Shore filled lintels as required. <br />3. Installation of lintel must comply with the architectural and/or structural drawings. <br />4. U-Lintels are manufactured with 5-1/2" long notches at the ends to accommodate <br />vertical cell reinforcing and grouting. <br />5. All lintels meet or exceed U360 vertical deflection, except lintels 17'-4" and <br />longer with a nominal height of 8" meet or exceed U180. <br />6. Bottom field added rebar to be located at the bottom of the lintel cavity. <br />7. 7/32" diameter wire stirrups are welded to the bottom steel for mechanical anchorage. <br />8. Cast -in -place concrete may be provided in composite lintel in lieu of concrete <br />masonry units. <br />9• Safe load ratings based on rational design analysis per ACI 318 and ACI 530 <br />10. Product Approvals: Miami Dade County, Florida Nos.03-0605.05 and 03-0605.04. <br />11, The exterior surface of lintels installed in exterior concrete masonry walls shall have <br />a coating of stucco applied in accordance with ASTM C-926 or other approved <br />coating. <br />12. Lintels loaded simultaneously with veritcal (gravity and uplift) and horizontal (lateral) <br />loads shoud be checked for combine loading with the following equation: <br />Applied vertical load + Applied horizontal load . O <br />Safe vertical load Safe horizontal load — <br />GENERAL CONCRETE LINTEL SCHEDULE <br />APPROVED LINTEL MANUFACTURERS: CASTE-CRETE, QUALITY, LOTTS <br />8F44 18/1 T 8F40 1 B/1 T 8RF400B/1T 81`321B/1T <br />FORM &GROUT SOLID <br />IY <br />CV < <br />o �W <br />' J <br />_Kz�� <br />O #5 BAR CONT. <br />8F12-1 B/1 T <br />O <br />V' LINTEL DETAIL <br />SCALE = N.T.S. <br />E <br />j <br />€ <br />i <br />3 <br />F = FILLED WITH <br />GROUT / U <br />= UNFILLED <br />R = RECESSED <br />QTY. OF #5 <br />REBAR @ BOTTOM <br />OF LINTEL CAVITY <br />Q <br />8 F 16— <br />B/ 1 T <br />U <br />a <br />tNOMINAL.QUANTITY <br />OF <br />WIDTH <br />WIDTH= <br />#5 REBAR AT <br />TOP <br />NOMINAL <br />HEIGHT <br />MATERIALS <br />cTi precastli tels = 3500 psi. <br />2. fc prestressed lintels = 6000 psi. <br />3. grouted per ASTM C476 fg = 3000 psi w/ <br />4. maximum 3/8" aggregate and 8" to 11" slump. <br />5. Concrete masonry units (CMU) per ASTM C90 w/ <br />minimum net area compressive strength = 1900 psi. <br />6. Reber per ASTM A615 Grade 60. <br />Prestressing strand per ASTM A416 grade <br />7. 270 low relaxation. <br />7/32 wire per ASTM A510. <br />8. Mortar per ASTM C270 type M or S. <br />#5 REBAR <br />M IN. <br />AT REQ'D <br />(1) <br />CLEAR <br />ALTERNATE POWERS <br />STEEL LINTEL <br />° <br />d O d <br />d <br />C.M.U. <br />#5 REBAR AT TOP <br />v-- <br />° d <br />- <br />> <br />d" d <br />o <br />GROUT <br />MIN. (1) REQ'D <br />1-1/2" CLEAR <br />0 <br />° e <br />d <br />< <br />J <br />a L <br />r !] <br />Ln <br />A <br />5 REBAR AT <br />M w (n <br />a <br />O <br />BOTTOM OF <br />Z- <br />r' cow <br />w O <br />o <br />LINTEL CAVITY <br />V <br />L O <br />OTTOM <br />REINFORCING <br />PROVIDED IN <br />LINTEL <br />0 U t- <br />m¢ ¢ (7 a) Z <br />Z° LL w U') <br />¢ _ - b � N <br />D D <br />#5 REBAR AT BOTTO <br />7-5/8"ACTUAL <br />' NOMINAL WIDTH <br />(VARIES) <br />U))'0 � Ca <br />�o �. �o <br />AS INDICATED <br />LINTEL MINIMUM DEPTHS ARE CALLED OUT ON LINTEL PLAN. IF CONTRACTOR INSTALLS A DEEPER <br />LINTEL THAN INDICATED ON THE PLAN, DOING THIS INCREASES THE STRENGTH OF THE LINTEL AND IS <br />APPROVED WITHOUT ENGINEERING LETTER. IF A SMALLER LINTEL IS INSTALLED CONTACT E.O.R. FOR <br />APPROVAL. (SEE LINTEL PLAN FOR SCHEDULE) <br />16 GAUGE POWERS <br />STEEL BOXED LINTEL <br />POWERS STEEL BOXED LINTEL NOTES (ALT.) <br />ONLY IF NOTED ON LINTEL PLAN <br />1. Refer to manufacturer's specifications for installation. <br />2. Contractor to provide proper protection of lintel to prevent rusting <br />Refer to manufacturer's specifications. <br />3. If lintel is scratched or damaged refer to Powers Steel for repair. <br />4. Lintel depth to match precast depth. One #5 Bar required at top <br />see lintel plan/details for bottom steel required. <br />5. A bonding agent must be applied to the Steel Box lintels prior to <br />applying the cementitiuos coating. See contractor specifications <br />O O <br />4'-6" LL 4'-6" LL <br />O <br />5'-10" LL <br />LINTEL PLAN - ELEV-Al <br />SCALE: %4"=V-0" <br />cp <br />al ca (,y �v� <br />q. <br />10R�4 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />44 <br />�i <br />00 0 <br />a � y N _N <br />AW <br />V m N N C Zo N LL00 <br />p u_ # W W <br />r» � u J n a <br />LL 22 <br />M W L1. fn Q' <br />. r Q a d 0.un': O <br />ca: <br />Z isL� 0 it <br />W, Oro <br />MO <br />�CN � <br />W m Or-r � ¢ o <br />W � ET � o a� <br />0 <br />Z NaMZ <br />J <br />Uun 13 <br />Z 1:1C1EJ0 <br />W <br />z N O <br />� o <br />� QNQ <br />Z O Q <br />J M <br />� N <br />z a <br />WL'n 'c <br />o <br />^' 0 W <br />VJ <br />— <br />Vi Y <br />w g <br />.0 <br />_ <br />N C o <br />�LO 22 <br />o <br />r- <br />U 0° <br />w rn <br />„ <br />c <br />r 2 E <br />o 8 <br />® <br />mf <br />CD <br />S to Y <br />® Q <br />Z <br />Cl) <br />M <br />wZ <br />o S <br />Z <br />z <br />a <br />r..r... <br />cdE <br />Z O <br />o O <br />E <br />I N <br />a N <br />fl- p <br />E V <br />Wz <br />❑a <br />Fcc3 <br />_ <br />O E <br />x o <br />Wp <br />0 o <br />O U <br />O (o <br />N <br />i <br />¢ <br />Wo <br />a <br />i <br />W Z <br />r� <br />W <br />M <br />Cn c <br />- C <br />o <br />z a <br />= Y <br />U <br />m 0 <br />O <br />Z r <br />(/) <br />W m <br />Q W <br />� <br />o� <br />z <br />0 <br />Q <br />OLL � <br />U <br />a <br />W W <br />C) <br />ao <br />�- <br />o <br />mZ <br />UJ <br />= <br />0 <br />' O <br />cfl <br />IW <br />�N <br />0 <br />= <br />` <br />J <br />L <br />m <br />.! <br />CO <br />�y c <br />CD <br />LLcaN <br />Q^ <br />N <br />LL <br />m <br />Cfl <br />... <br />d- <br />Z ,- <br />r <br />a <br />TT CN <br />� <br />r <br />ci <br />0 <br />('') T <br />N ti N <br />o <br />Z <br />Z <br />E O N 77 <br />co <br />� <br />c <br />CL <br />E ` a) <br />v � ¢ o <br />� <br />JOB <br />NO: 20-1130 <br />SCALE : AS NOTED <br />SHEET NO. <br />8 <br />