Laserfiche WebLink
KITCHEN <br />SEE PLAN FOR LANDING DEPTH <br />MIN. (3) 2x STUDS REQ'D <br />@ END OF LANDING <br />BELOW HDR. BEAM. <br />STANDARD (3) 2x12 <br />STRINGERS w/ SIMPSON <br />A35/USP MP34 CLIP TO FLOOR <br />SYSTEM OR LANDING FRAMING <br />(2) 2x HDR. REQ'D @END OF <br />LANDING FOR STRINGERS <br />TO CONNECT TO <br />I <br />oc <br />PLY SHEATHING OVER <br />LANDING ATTACHED PER <br />GENERAL FLOOR <br />CONSTRUCTION NOTES <br />2x8 #2 SYP JOISTS @LANDING <br />@ 16"O.C. w/ SIMPSON A35JUSP <br />MP34 OR LUS26 HANGER ON <br />EA. SIDE <br />MASONRY OR WOOD WALL, <br />SEE PLAN <br />2x8 #2 SYP (P.T. IF MANOONRY <br />WALL) CONT LEDGER w/ (3) 16d <br />NAILS @ 16" O.C. MAX. TO EA. <br />STUD. ((2) 1/4"X3 1/2" TITENS @ <br />16" O.C. MAX. FOR MASONRY <br />WALL) <br />GENERAL LANDING FRAMING INFO. <br />SCALE: N.T.S. <br />9'-0" MAX LANDING LENGTH <br />v <br />J <br />" PLYWOOD @ <br />LANDING <br />A. <br />�— 2x8 LEDGER #2 SYP w/ <br />(3) 16d NAILS TO STUD <br />Nb� @ 16" O.C. <br />MIRROR <br />O <br />0 <br />KITCHEN <br />2x8 #2 SYP JOISTS @LANDING <br />@ 16" O.C. w/ SIMPSON A35 <br />CLIP OR LUS26 HANGER TO <br />LEDGER I U <br />2x12 HDR. w/ (3) 2x STUDS AT Q <br />EA. END FOR BEARING I � <br />w <br />STANDARD (3) 2X12 I U <br />STRINGERS W/ SIMPSON A35 � <br />CLIP TO HDR. � w <br />1 x TREADS (TYP.) .- <br />CONT. <br />HANDRAIL <br />THRUST BLOCK SECURED TO <br />SLAB w/ 1/4"X3 1/2" TAPCONS <br />@ 16" O.C. <br />0 <br />OWNER'S BATH <br />O <br />M <br />O <br />cV <br />0 <br />M <br />PRE-ENG FLOOR JOIST W/ (2) <br />LAYERS OF 3/4" PLYWOOD <br />FOR SOLID NAILING <br />KITCHEN ISLAND <br />CONT. HANDRAIL <br />1x RISERS (TYP.) <br />STANDARD (3) 2X12 <br />TRINGERS W/ SIMPSON <br />A35 CLIP TO FLOOR <br />SYSTEM <br />2x8 #2 SYP JOISTS @LANDING <br />@ 16" O. . w/ SIMPSON A35 CLIP <br />OR LUS2 HANGER EA. SIDE SEE <br />PLAN FOR CLG. HT. <br />2x12 HDR. w/ (3) 2x STUDS AT <br />EA. END FOR BEARING <br />INTERIOR ELEVATIONS <br />SCALE: 1/2"=1'-0" <br />STAIR CALCUTIONS: <br />TOTAL RISE = 10'-0 3/4" <br />(16) RISERS AT 7 9/16" <br />10" TREADS w/ 1" NOSING <br />Stairway construction and handrail to conform to <br />residential section R311.7 <br />Riser height: <br />The maximum riser height shall be 7%4'. The greatest riser height within any <br />flight of stairs shall not exceed the smallest by more than %$°. <br />Tread depth. <br />The minimum tread depth shall be 10". The greatest tread depth within any <br />flight of stairs shall not exceed the smallest by more than <br />Nosings. <br />The radius of the nosing shall be no greater that %s'. Solid riser nosings shall <br />not be less than'/" but not more than 1/4'. The greatest nosing projection shall <br />not exceed the smallest by more than y2'. Beveling of nosings shall not exceed <br />Yz" <br />Handrails. <br />Handrails shall be provided on at least one side of each continuous run of <br />treads or flight with four or more risers. Handrail height, measured vertically <br />from the sloped plane adjoining the tread nosing, or finish surface of ramp <br />slope, shall be not less than 34"and not more than 38". Handrails adjacent to a <br />wall shall have a space of not less than 1y2'between the wall and the handrails. <br />Grip -size. <br />Handrails with a circular cross section shall have an outside diameter of at <br />least 1 1/4"and not greater than 2" or provide equivalent graspavility in <br />compliance with FBC 5th Edition (2014) Residential Section R311.7.8.3. <br />Guards. <br />Guards shall be located along open -sided walking surfaces, including stairs, <br />ramps and landings, that are located more than 30"and shall be not less than <br />36". Required guards shall not have openings from the walking surface to the <br />required guard height which allow passage of a sphere 4" in diameter.1:A <br />= Winders. <br />Winder treads shall have a minimum tread depth of 6" at the narrow end and <br />shall have a minimum tread depth of 10" at the intersections with the walkline <br />— — — — (12" from the narrower side). <br />R302.7 Under -Stair Protection. <br />Enclosed accessible space under a stairway shall be protected with Yz' gyp. bd <br />STAIR SECTION <br />SCALE: 1/2"=1'-0" <br />U r <br />zM <br />0 <br />z� <br />Q <br />J <br />�1■I IAmI"IIPElfff 1! <br />Z19 <br />E3CL <br />UU_ <br />to Ce) <br />) <br />7CL <br />- <br />1 La <br />VIA <br />0 <br />,0LL 9 <br />(1)4-0 <br />Z E <br />V00-0 <br />) <br />Uoz <br />Lu <br />2 <br />Cal LU <br />, <br />10 <br />