My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3130 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3130 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 11:46:16 AM
Creation date
2/19/2025 8:52:58 AM
Metadata
Fields
Template:
Building Plans
Street #
3130
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19245
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
00 <br />DO <br />T.O.P. <br />HDR HGT. <br />2nd FIN. _ _ _ _ <br />FLR. <br />T.O.M. <br />HDR HGT. <br />F.FL. <br />12 <br />5� <br />REAR ELEVATION - B1 <br />SCALE: 1 /4"=1 r-0" <br />12 <br />12 <br />�5 <br />— — — — T.O.P. , <br />HDR HGT. <br />LEFT ELEVATION - B1 <br />SCALE: 1 /4"= V-0" <br />A. <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SO. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN, OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. <br />(Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 172 = Amount of O'Hagin Vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SO. IN. OF NET FREE AREA / FT. <br />'Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 9 = Linear Ft. of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SQ. IN. OF NET FREE AREA / VENT <br />*`Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) / 86.25 = Amount of O'Hagin Vents Needed <br />a <br />0 LO <br />M <br />o <br />_ <br />Z C° <br />z <br />Q <br />J <br />tJ) Z <br />Q) <br />cr7 <br />CD(Z <br />a--d LL, <br />0 <br />U — <br />0f 11 <br />OJ <br />o <br />� LM <br />o 0 <br />m <br />U <br />t.lJ <br />h- EE <br />- 8 <br />(D M <br />c RL M <br />O OO <br />N <br />N <br />L LL CO <br />ouU)i <br />Qft` <br />0 <br />Q rn <br />rnQ o <br />A ' <br />N C B D C <br />i,xx <br />/ <br />P <br />INN C14 <br />co <br />6 <br />CL <br />.c <br />29 <br />'£ 04 <br />ja.���' ��•+c'0� <br />�z <br />1 <br />o <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />0 <br />0 <br />Z cV <br />N <br />0 <br />ate) <br />L/-t U M O <br />„ M <br />Q <br />r3. to •i, d' <br />Q LL <br />H C).. M <br />QY U 00 <br />a <br />u <br />E <br />z <br />WJ C:) <br />oz <br />=o <br />o! o <br />Z a <br />Z¢ <br />~ <br />'^ <br />V J <br />z <br />w ¢ r <br />Uz0O <br />0 <br />Z21X <br />Q <br />i -0Z Z <br />0,oL4w <br />o W o <br />LU <br />U <br />m <br />w�0 <br />J <br />W <br />oN <br />z <br />Qo <br />U <br />w <br />z z <br />z <br />C) <br />o <br />I ^ <br />L / <br />� <br />r <br />z <br />o <br />o <br />a <br />U <br />_ <br />fN <br />QuJ <br />CC <br />w <br />ov <br />< <br />W <br />�XIS <br />v�a <br />N <br />A <br />` <br />Z a U w <br />w Z J <br />C7QZ¢ <br />Q <br />g0�� <br />z <br />Z <br />Lfi <br />WaU-o <br />a <br />w <br />��&5 <br />W <br />LU <br />a <br />Z <br />0Zo <br />w U <br />W~~ <br />z <br />��z <br />co <br />rwt' <br />0 <br />o <br />g <br />= <br />w <br />T—q <br />a <br />to <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAMES <br />VERSION NO. <br />I2m0 <br />SHEET NO. <br />3.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.