ELECTRICAL SPECIFICATION <br />200A <br />INDOOR PANEL <br />CENTER <br />NOTES: <br />#14 copperto lights &outlets <br />ELECTRICAL CONTRACTOR <br />NEMA 1 01 #12 copper to 20 amp ckts <br />200 AMP <br />MUST VERIFY WITH THE <br />#10-2 copperto WH <br />SPECIFICATIONS FOR THE TYPE <br />#10-3 copperto Dryer <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />METER <br />LOCATION PURPOSES. <br />MAINT <br />200 amp <br />2/0 or 4/0 SER Alu <br />150 amp <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FqT <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />FW <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />j <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4, � <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 <br />4 Bare Cu Ground <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />© EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) FC SYSTEM <br />El PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />PM ELECTRIC METER <br />ELECTRIC PANEL <br />_1111111M.-J! DISCONNECT SWITCH <br />® SPEAKER (OPTIONAL) <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />C/ CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR UPPER ELECTRICAL PLAN <br />< J OPT. CEILING FAN <br />b� (1) PHONE LINE, (1) DATA PORT SCALE: /4"=1'-0" <br />C,� r <br />M <br />Oo <br />Z <br />d <br />O <br />J <br />n_ <br />U0 CD <br />�✓ C-n <br />LLI <br />U — <br />Lll <br />0 <br />E <br />o <br />`✓� <br />00 <br />U <br />0 M <br />Cm <br />LU <br />I.-_-2 <br />pp <br />® U <br />M <br />N <br />O O O <br />aa)) <br />U <br />s i1 co <br />cj <br />p Y <br />CID <br />= o <br />'n o 4 <br />drn <br />rnQo <br />A1 <br />B D® <br />NCBDC <br />ti <br />o <br />V' CV <br />co <br />N <br />0 <br />(p <br />ooo <br />H �°' <br />�tiN <br />N <br />0 00 <br />0 <br />o <br />Z W C o <br />1.D7 <br />/y lL <br />L.L <br />N <br />W (n rnMN <br />C lL C <br />w <br />d W <br />d <br />10Z V a a .—t�. <br />z <br />3 <br />C <br />0 <br />�o <br />Z Uo^o <br />y190m <br />O <br />m <br />LL Z <br />Q N <br />Q <br />J <br />;Z <br />W N M <br />O <br />< O0 <br />U <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z (V <br />O <br />>�°o <br />M <br />- In <br />Q <br />CL <br />OC U fu <br />E' 00 <br />Q <br />J <br />W <br />� <br />d' <br />oZ <br />za <br />a� <br />EF <br />Z <br />w ¢ X <br />oQ-o <br />ZwuJ WQ <br />F 7 Z Z <br />g Z J <br />Q <br />j <br />oWceo <br />V <br />"F a <br />� <br />oZ <br />Zo <br />N <br />J <br />Zz <br />LJJ <br />J <br />N <br />LIJ <br />0 <br />' ^ <br />y / <br />o <br />o <br />= <br />N <br />O <br />J Q <br />o <br />J <br />LL <br />oLU <br />� U-°o <br />F� <br />Qr <br />J <br />?ar <br />i Y=' <br />c <br />W 0 0 <br />fN <br />fN <br />o¢o¢ <br />0 <br />goo <br />Z <br />Z <br />W <br />J <br />T�i <br />Uj <br />2 <br />di <br />Q <br />F Z o <br />Uja8 <br />d <br />Q <br />Z <br />~ <br />��Z" <br />0 <br />Z <br />ji <br />RZ <br />m <br />^ <br />� <br />_ <br />¢Z <br />Z <br />rn <br />T-'I <br />d <br />(n <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.1 <br />