Laserfiche WebLink
CORNER OF <br />HOME <br />GARAGE SIDE <br />— — — I <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />O O O <br />01 5'-0" <br />STUB -OUT FOR 1,-O„ o 0 0 <br />GAS METER O - 0 <br />O 0 <br />(V = <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) - 12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) - 12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />7'-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4) 16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-1" <br />(2) 16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-0" <br />(3) 16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'-4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RIDGE LINE <br />CoPL/YWOOD <br />OR <br />7/16" OSB <br />IDGE LINE <br />140 MPH <br />(ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />+ + 0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: FOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER. IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />0 ")a <br />+ + + + + + + + + + + + + + + + + + + + + + + + + +(D <br />+ + + + + + + + + + + + + + + + + + + + + + + + + + <br />+++ ^1+ <br />+++ <br />+ + <br />+++ +++ <br />+ ++ + + + + + + + + + + + + + + + + + + + + <br />+ + + + + o + + + + + + <br />+ + + + + + + + + + + + + + + + + + + + + + + <br />++ +++ ++++++++ + <br />oil <br />:'W /r <br />(, NI& L" <br />W LW <br />Ir. Ct <br />2 <br />UA )�x <br />z 0 <br />Lu <br />U <br />10 <br />Backer and Filler Block Dimensions <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" <br />5000s 1.8/1.7 <br />p nel <br />wood panels <br />Two 3/4" wood panels or 2 x — <br />1-1 /8" or two 1 /2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1 /2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />1-1 /8" or two 1 /2" <br />602.0 <br />wood panels <br />2 x _ + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />r <br />Filler blocking <br />1/8" gap <br />i <br />FILL CELL <br />STD. 900 HOOK BOND BEAM <br />. <br />... <br />........................ <br />...... <br />> STD. 90° <br />CONT. #5 <br />CONT. #5 <br />BAR <br />HOOK <br />BAR <br />#5 CONT. <br />FROM <br />NDATION <br />TOHIGHEST <br />1 <br />BOND BEAM <br />BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIOR/EXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMN PLYWOOD FLOOR <br />SEE PLAN FOR REQ'D SHEATHING PER PLAN <br />COLUMN AND <br />CONNECTION TJI TO BE CUT TO ALLOW <br />/ FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />' OTHERWISE SOLID <br />BLOCKING TO MATCH <br />L Solid block all posts from # OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRIG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />2" max. � 4" max. <br />4 <br />Clinch nails <br />when <br />possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. _T <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 2x4/Plywood/OSB web stiffener 2 min. <br />required when indicated or 4 max. <br />2x_: CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT at 12" o.c., clinched when possible. Stagger rows from opposite - Hangers with side nailing. <br />OF THE JOIST ASA REQUIRED LEAVING %" GAP @ TOP sides by 6". - Hangers with sides not containing WEB STIFFENER <br />top flange of joist. <br />DOUBLE JOIST CONNECTION - Birdsmouthcuts. N.T.S. <br />N.T.S. - Under 2nd floor column w/ loads <br />hi her than 15001b <br />Web Stiffener Fastener Schedule <br />Joist BearingLocation <br />Series Depth End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />BCI6000s® <br />BCI6500sw <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI60s® <br />11-7/8" <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />9 <br />BLOCKING PANEL, INTERIOR <br />SQUASH BLOCKS AT INTERIOR Boise Joist Blocking Vertical load transfer=1900 plf max. along bearing wall <br />BEARING Use 3" (10d) nails at 6" o.c. Required on interior walls : - for vertical load transfer Plumbing <br />Load bearing walls when load bearing - for lateral support when joists <br />Vertical load transfer =1900 plf max along load bearing wall. meet over wall, or wall stacks directly over wall or <br />Load bearing wall must stack beam below <br />* over squash=20 blocks and Load bearing wall must stack over <br />Non -stacking walls wall or beam below.* blocking and wall or beam below.* <br />require additional <br />consideration. Check Joist <br />local building When joists meet over wall, provide <br />code for appropriate 11/16" 1 3/4" minimum bearing for each. I -Joist can be offset <br />details in One 10d box up ti 3 to avoid <br />areas=20 of high Zor=20 sinker vertical plumbing <br />lateral load. nail each side 3" max <br />at bearing. JOISTS OFFSET <br />N.T.S. <br />Provide adequate bearing <br />for each lapped joist. Use 10dx3" nails at 6"o.c. for all joist <br />blocking panel *Non -stacking walls <br />Squash block) 10d nails SECTION @INT. BRIG. WALL require additional consideration. <br />2x4 minimum <br />Bearing wall, Versa -Lam LVL or N.T.S. <br />Glulam Beam <br />NO HOLES (EXCEPT MINIMUM SPACING = 2x GREATEST <br />KNOCKOUTS) ALLOWED DIMENSION OF LARGEST HOLE <br />IN BEARING ZONES D (KNOCKOUT EXEMPTS) <br />(see table below) D <br />(see table below) <br />DO NOT cut, notch <br />or drill flanges <br />6" A 1 2" ROUND HOLE MAY 6„ 6„ DO NOT CUT HOLES <br />BE CUT ANYWHERE IN CANTILEVER LARGER THAN 1" <br />THE WEB. PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW, IS REQUIRED FOR ALL HOLED GREATER THAN 1Y2" <br />8 <br />T-{) <br />1'-11" <br />l'-.2' <br />1'-2' <br />.I'-3' <br />1'-3' <br />1'-7"' <br />V-11 <br />2�4' <br />2-9' <br />3 2"' <br />3'-7 <br />Arty 16" jcxst <br />12 <br />T- <br />1"" <br />1'-Z' <br />I _2,. <br />1'-3' <br />1'-3' <br />2-4"' <br />2'-11" <br />3. 7' <br />4, Z. <br />4.�. <br />9-41 <br />GP_�? .t) <br />16 <br />T-a' <br />1'-1" <br />1' 2f' <br />1-2'" <br />1 7' <br />2'-9' <br />3'-2' <br />3 10" <br />4�" <br />S' - <br />�6'•4 • <br />7 �' <br />20 <br />T-a' <br />T-1" <br />T-Z' <br />1' 2" <br />2—a- <br />3-0" <br />4'-0" <br />4'-10" <br />15-11" <br />24 <br />1'-0'" <br />1'-1" <br />1` 2" <br />1-3" <br />2-5- <br />3'-T° <br />4'-9' <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED TO MEET BUILDING CODE REQUIREMENTS, <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE %" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE TO CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />Joist hanger <br />U; <br />M <br />5/811, <br />THE <br />BOL <br />R TRUSS <br />'OP PLATE <br />I.0 <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />VIIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 /HTA 20 <br />INSTALLATION <br />A/C CHASE 4" PVC <br />SLEEVE THRU STEM <br />WALL <br />Backer block (12" wide min.) — <br />Nail with 10-10d nails. <br />Install tight to top flange. SLEEVE THRU STEM 4 ° <br />°. <br />SEE PLAN FOR--'°. ° , • <br />FOUNDATION INFO <br />STEM FOUNDATION <br />\ \ Filler block. <br />Nail with <br />10-10d nails. <br />Backer block required where top <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4"-2" gap <br />I <br />Backer Block <br />'Top Mount "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4%2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange. <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger. doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />D depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />GRADE <br />REINF. SEE PLAN <br />1 <br />zL <br />A/C CHASE 4" PVC (2) #5 REBAR <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />LC <br />SE <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />NOTE: <br />UPLIFT VALUE <br />IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d A 1/2" NAILS <br />UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />PIPE VERTICAL THRU FND. <br />TOP (2) #5's x 4' -0" <br />CENETERED @ PIPE <br />PENETRATION <br />q <br />`PVC OR SCH40 SLEEVE <br />/ PLUMBING � LINE <br />..a / <br />i a �° � •a <br />4 <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PVC OR SCH40 SLEEVE <br />PLUMBING LINE <br />. ° f • na L <br />a d <br />v 4' .v <br />'1 I' <br />.o <br />SEE FND. PLN. <br />SIZE & REINF. <br />Z M <br />0 <br />Z <br />Q O <br />J <br />W cn <br />0 <br />O w I— <br />c.n � <br />oa <br />U wM <br />W C co <br />� E N <br />M <br />— $ 080 <br />0 <br />C d � o 0 <br />Qrn rnQo <br />A1 N C B D C <br />B D• <br />11�Y11 i <br />Y c� <br />o'0 m` <br />/�j�o�V//lJIi11111\°��, ❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code Sth Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering por0 tions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />Z � <br />�>-+HMO <br />�i M <br />a U,) -(0p Lr) <br />a cn •L d- <br />Q U o- o0 <br />Z � � <br />WJ C:) <br />d- <br />oZ <br />�o <br />zaa <br />aQ <br />EF <br />wair� <br />��oo <br />zwwz <br />�p�wJz <br />J <br />d Q <br />� <br />0 <br />V �LLN <br />00 Cn w <br />FWo <br />oV) <br />L M W zz <br />O C: <br />= w <br />QcO��Co <br />oaa,m� <br />fV � Z�od <br />0 <br />Q b" ~�fo <br />Z � �o,go <br />w In o <br />J � W C owu G C) Y ¢ <br />l0 Q Z U�o <br />¢�Z <br />a`�^ <br />Z <br />� Z W Qo <br />o � g <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: FGUZMAN <br />VERSION N0. <br />0 <br />SHEET N0. <br />SN 1 <br />,;,�:.�. Wn w.. .II .� iI.�u-." —T-T <br />,;,�:.�. Wn w.. .II .� iI.�u-." —T-T <br />