My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3139 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3139 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/26/2025 12:48:18 PM
Creation date
2/19/2025 8:53:29 AM
Metadata
Fields
Template:
Building Plans
Street #
3139
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
22333
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br />rn <br />55'- <br />A <br />S3 <br />M <br />8'-6" <br />I <br />036 <br />360 <br />5-SH T <br />6" DP-- <br />R <br />----&S ---- <br />BUILDERTO <br />N PROVIDE <br />INE <br />I <br />W.H. APPLIANCE <br />I <br />I <br />I <br />I <br />I <br />K TYP @ <br />I <br />p PROTECTION <br />I <br />I <br />I <br />S4 GARAGE <br />' <br />OWNER'S SUITE <br />W. I. <br />2'-6" WHEN REQUIRED <br />PER FBC <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />OPENING <br />■ <br />B <br />I <br />I <br />I <br />rn <br />CARPET <br />60 <br />- <br />TIE <br />_ <br />8'-0" CLG.� <br />CARPET <br />2 CAR GARAGE <br />I <br />I <br />I <br />I <br />I <br />I <br />rn <br />OU)Lu <br />17'-8" <br />ii0 <br />I r <br />- <br />- <br />T-8" <br />� <br />(� <br />I <br />�� <br />8 -0 CLG. 20'-0$„ <br />I <br />I <br />I <br />I <br />18 <br />I <br />`'' w <br />2668 <br />I <br />I <br />tY <br />2 <br />I <br />I <br />Q I <br />I <br />91,168- <br />HANSON <br />1 <br />I <br />0 l <br />l <br />I <br />o <br />BOX @ 36" <br />EDGE OF SLAB 2" <br />BEYOND WALLv <br />I <br />I <br />Qo I <br />I <br />o <br />A.F.F. <br />60"x36" <br />DRYER VENT <br />K <br />S3 <br />I <br />W I <br />I <br />N <br />SHOWER <br />THRU ROO <br />I <br />I <br />> I <br />I <br />00 <br />000 3 <br />(3) 2x4 #2 SPF w/ <br />FIBERG <br />SS "' <br />&S <br />I 11 <br />I <br />I <br />X00 <br />I <br />I <br />DTT2Z @ BASE <br />RROU <br />D <br />I l l I <br />I <br />o I <br />I <br />T <br />TYP @ 1 STORY <br />5 -118 <br />I <br />4'-0" <br />PT W OPT. D <br />S3 <br />IIx I <br />NOTE: FINISHED <br />I <br />I <br />Liku N.L <br />N <br />I1 a UQII7 <br />WALLS TO BE <br />I <br />I <br />AHU <br />J <br />I <br />FLUSH. VERIFY IN <br />I <br />I <br />7 <br />I <br />CD <br />- <br />I <br />I FIELD. <br />I <br />I <br />zo <br />CF7 <br />I <br />; <br />TILE <br />L <br />d <br />K <br />CC <br />D <br />1 <br />00 <br />S3 (3) 2x4 #2 SPF w/ <br />S3 <br />S3 <br />6 <br />8 <br />8 <br />DTT2Z @ BASE <br />= <br />I <br />I FAMILY RM <br />R.A.G. <br />O m <br />2:12 VAULTED CLG.` <br />^ <br />9'-4" CLG. <br />rn <br />CARPET <br />FD <br />3068 <br />; <br />I r <br />^,�°° <br />9'-4'CL <br />ENTRY <br />iD <br />in <br />23'-8" <br />M <br />T-10" <br />T-8" <br />10'-10$" �, <br />6„ 7 „ 4' „ <br />8'-0" CLG. <br />I <br />I <br />HDRATT4" <br />------- <br />owl' <br />' <br />I <br />i� <br />--------------- <br />R&S <br />i <br />2668 io <br />2668 <br />r <br />R&S <br />------------ <br />4'-0" <br />3 <br />1 V-7g <br />6'-10" <br />04 <br />4, 7„ <br />8,_8„ N <br />5,4„ <br />ih <br />14'-6" <br />I.- <br />5'-4" M <br />N T-6" <br />N <br />I <br />I <br />I <br />in <br />5068 B.F. <br />4068 B.F. <br />j <br />OPT. I <br />I <br />I <br />REF.fi- <br />_ _ <br />BEDROOM <br />2 <br />oto <br />"' <br />co <br />z <br />PATIO <br />CAFE <br />�' W <br />w <br />------------- <br />F---------- <br />r-_-� <br />_ <br />I • • <br />8-0 CLG. <br />' " <br />BEDROOM 3 <br />N <br />�� <br />BEDROOM 4 <br />co <br />VAULT. CLG. <br />CARPET <br />' <br />N D C� <br />I D.W. I <br />O� <br />I <br />I <br />CARPET <br />8'-0" CLG. <br />I <br />17 <br />CLG. <br />cnw <br />M� O <br />o <br />T <br />vOi <br />"' O <br />i <br />I <br />7 a J <br />N U <br />3L _ 24 _ <br />SI Kw/ ISP <br />8 3 <br />a I <br />b°° <br />CARPET <br />I <br />I <br />ILE <br />2" <br />CARPET <br />CA <br />M0 <br />w <br />r <br />M <br />/' <br />21'-2" <br />2,_ „ 2, R „ <br />_� <br />10'-4" <br />10'-42' <br />2,-4, I <br />5'-3 <br />_7 <br />i <br />M�v <br />TIE <br />_JF <br />ti <br />I carp- <br />I c <br />I <br />b0 <br />rn <br />■ <br />I <br />ANT Y <br />_ <br />� <br />TYP 1 <br />/�� <br />iv <br />=W <br />U) <br />T <br />STORY <br />? <br />36 <br />36 <br />o <br />T L .,nc <br />I <br />FIBERGLASS <br />I <br />A <br />14 AC PAD <br />/�i <br />I <br />- _ <br />---- O <br />---� <br />: <br />5-SH T <br />I <br />I <br />SURROUND ° <br />M <br />S3 <br />/ <br />16" DEEP <br />H B <br />EGRESS <br />EGRESS <br />O <br />(:Si) <br />O <br />29'-8" <br />15'-10" <br />0 <br />O <br />HEADER SCHEDULE <br />MARK <br />HEADER SIZE <br />REMARKS <br />H 1 <br />(2) - 2X6 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H2 <br />(2) - 2X8 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H3 <br />(2) - 2X10 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H4 <br />(2) - 2X12 #2 SYP W/ 1/2" <br />FLITCH PLATE <br />H5 <br />(2) -1 3/4" X 11 1/4 LVL <br />2.0E Fb=2600 PSI <br />H6 <br />(2) - 1 3/4" X 9 1/4" <br />LVL 2.0E Fb=2600 PSI <br />H7 <br />(2) - 1 3/4" X 16" <br />LVL 2.0E Fb=2600 PSI <br />H8 <br />(2) - 1 3/4" X 7 1/4" <br />LVL 2.0E Fb=2600 PSI <br />(2) - 2X4 #2 SYP W/ 1/2" Follow Q/S4. See Plan for <br />R.A.G. FLITCH PLATE Bearing Wall Call Out When <br />Straps are Required <br />*VERIFY W/ PLAN CORRECT LENGTH OF HEADER REQUIRED <br />** SEE PLAN FOR DETAIL CALL OUT FOR CONNECTIONS AND <br />REQUIRED STUDS <br />WINDOW SCHEDULE <br />SIZE <br />R.O. CMU <br />(Flange) <br />R.O. FRAME <br />(Fin) <br />TYPE <br />12 <br />20 X 26 <br />18 J X 25 4 <br />S.H. <br />13 <br />20 X 38 j <br />18 4 X 37 1 <br />S.H. <br />14 <br />20 X 50 j <br />18' X 50 <br />S.H. <br />15 <br />20X63 <br />184X62 <br />S.H. <br />16 <br />20 X 72 <br />18 4 X 714 <br />S.H. <br />11-12 <br />271/4X26 <br />26X254 <br />S.H. <br />1 H3 <br />27 114 X 38 j <br />26 x 371 <br />S.H. <br />1 H4 <br />27 J X 50 i <br />26 x 50 <br />S.H. <br />11-15 <br />27JX63 <br />26X621/2 <br />S.N. <br />111-16 <br />27jX72 <br />26X711/2 <br />S.H. <br />22 <br />37 1 X 26 <br />36 4 X 25 1/2 <br />S.H. <br />23 <br />37 j X 38 j <br />36 4 X 37 3/4 <br />S.H. <br />24 <br />37 j4 X 50 j <br />36 4 X 50 <br />S.H. <br />25 <br />37 J X 63 <br />36 4 X 62 1/2 <br />S.H. <br />26 <br />37 ja X 72 <br />36 # X 71 1/2 <br />S.H. <br />DOUBLE 2 WIDE <br />75" TALL <br />73 J WIDE <br />S.H. <br />32 <br />54 X 26 <br />52 4 X 25 i <br />S.H. <br />33 <br />54 X 38 j <br />52 } X 37 1 <br />S.H. <br />34 <br />54 X 50 1 <br />52 " X 50 <br />S.H. <br />35 <br />54 X 63 <br />52 4 X 62 <br />S.H. <br />36 <br />54 X 72 <br />52 4 X 71 <br />S.H. <br />39X59 <br />40 X 59 <br />N/A <br />S.H. <br />DOUBLE 39X59 <br />79 X 59 <br />N/A <br />S.H. <br />TIE WALLS TOGETHER BY ROTATING <br />BLOCKS EVERY OTHER COURSE <br />General Notes <br />R302.5 Dwelling/Garage Opening/Penetration Protection. <br />Opening and penetrations through walls or ceilings separating the <br />dwelling from the garage shall be in accordance with sections <br />R302.5.1 through R302.5.3. <br />R302.5.1 Opening Protection. Openings from a private garage <br />directly into a room used for sleeping purposes shall not be <br />permitted. Door between garage and residence shall be equipped <br />with solid doors not less than 1 3/8" in thickness, solid or <br />honeycomb -core steel doors not less than 1 3/8" thick, or <br />20-minute fire -rated doors. <br />R302.5.2 Duct Penetration. Ducts in the garage and ducts <br />penetrating the walls or ceilings separating the dwelling from the <br />garage shall be constructed of a minimum No. 26 gage (0.48 mm) <br />sheet steel, 1 inch minimum rigid nonmetallic class 0 or classl <br />duct board, or other approved material and shall have no openings <br />into the garage. <br />R302.5.3 Other Penetrations. Penetrations through the separation <br />required in Section R302.6 shall be protected as required by <br />section R302.11, Item 4. <br />R302.6 Dwelling/Garage Fire Separation. <br />The garage shall be separated from the dwelling as per the <br />following: <br />• From the Residence & Attics - Not Less than 1/2" Gyp. Bd. or <br />equivalent applied to garage side. <br />• From Habitable Rooms Above Garage - Not Less than 5/8" <br />Type-X Gyp. Bd. or equivalent. <br />• Structure(s) Supporting Floor/Ceiling Assemblies - Not Less <br />than 1/2" Gyp. Bd. or equivalent. <br />• Garages Located Less Than 3 Feet From Dwelling On The <br />Same Lot - Not Less than 1/2" Gyp. Bd. or equivalent applied <br />to the interior side of exterior walls that are within this area. <br />R312.2.1 Window Sills. <br />In dwelling units, where the top of the sill of an operable window is <br />located less than 24 inches (610 mm) above the finished floor and <br />greater than 72 inches (1829 mm) above the finished grade or <br />other surface below on the exterior of the building, the operable <br />window shall comply with one of the following: 1. Operable <br />windows with openings that will not allow a 4-inch-diameter (102 <br />mm) sphere to pass through the opening where the opening is in <br />its largest opened position. 2. Operable windows that are provided <br />with window fall prevention devices that comply with ASTM F2090. <br />3. Operable windows that are provided with window opening <br />control devices that comply with Section R312.2.2. <br />Chapter 45 Private Swimming Pools, Section R4501.17.1.9 <br />All doors and windows providing direct access from the home to <br />the pool shall be equipped with an exit alarm complying with UL <br />2017 that has a minimum sound pressure rating of 85 db at 10 <br />feet. Any deactivation switch shall be located at least 54 inches <br />above the threshold of the access. Separate alarms are not <br />required for each door or window if sensors wired to a central <br />alarm sound when contact is broken at any opening. <br />M1507.2 Recirculation of Air. <br />Exhaust air form Bathrooms and toilet rooms shall not be <br />recirculated within a residence or to another dwelling unit and shall <br />be exhausted directly to the outdoors. Exhaust air from bathrooms <br />and toilet rooms shall not discharge into an attic , crawl space or <br />other areas inside the building. <br />GAS APPLIANCES <br />G.C. to verify location of gas riser before commencement of work. <br />Where gas water heaters are installed. Water heaters shall be <br />installed a min. of 18" above fir. per FBCR G2408.2. Except where <br />appliances that are listed as flammable vapor ignition resistant. <br />OPENING PRESSURES <br />ENCLOSED-EXPOSURE"C" <br />AO <br />+29.7 / -30.8 <br />© <br />+29.7 / -39.2 <br />© <br />+28.3 / -30.8 <br />OD <br />+28.3 / -36.4 <br />DE <br />+26.6 / -28.0 <br />OF <br />+26.6 / -32.2 <br />GG <br />SEE SN SHEET OH SEE SN SHEET <br />140 MPH timoft <br />NOTE: WIND SPEED INDICATED ABOVE IS AN <br />"ULTIMATE" WIND SPEED. THE WIND PRESSURES <br />LISTED ABOVE ARE ALLOWABLE PRESSURES <br />SOFFIT DESIGN PRESSURE <br />1 +34.0 / -44.8 <br />WALL LEGEND <br />MASONRY HGT. @ 8'-0" A.F.F. <br />TYP. 2x FRAME WALL <br />BEARING WALL <br />INTERIOR BEARING WALLS NOTED "FLOOR BEARING <br />ONLY" ARE FLOOR SYSTEM SUPPORTING ONLY AND <br />REQUIRES NO UPLIFT CONNECTORS TO FLOOR <br />SYSTEM <br />AREA TABULATION "A1" (TRA) <br />1 ST FLOOR LIVING AREA 1936 <br />LIVING TOTAL 1936 <br />GARAGE 416 <br />FRONT ENTRY 20 <br />TOTAL AREA 2372 <br />INSULATION REQ. <br />LOCATION R-VALUE / TYPE <br />EXT CONC WALL R-4.1 HIGH PERM <br />EXT FRAME 2 x 4 R-11/R-13 KRAFT FACED <br />EXT FRAME 2 x 6 R-13 KRAFT FACED <br />FLOOR PLAN - ELEV-Al <br />CONDITIONED CEILING R-0 BLOWN -IN <br />(INSTALL BAFFELS AT EAVE) <br />GARAGE SEPARATION R-11/R-13 KRAFT FACED <br />SCALE: li4"=1'-0" (GARAGE / LIVING) <br />li <br />Q <br />G <br />® <br />Q <br />e <br />91144SEfE0tP �, <br />Ok <br />P <br />o <br />•.°e <br />x,v �-•. <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and <br />seal is only for <br />the structural engineering portions of the drawing pages beanng <br />Engineers signature and seal. <br />sm W <br />Am AWL <br />E <br />m <br />N <br />ie <br />a <br />9V <br />o0o <br />M <br />J J <br />LL <br />N <br />M N <br />emu- <br />CoLL <br />JLLLawa <br />M1w <br />N <br />6- LU <br />W O <br />LL <br />aim <br />a. <br />�S o <br />Z <br />a_ <br />-29� <br />mmoo <br />W <br />cc 0C N <br />W <br />z <br />ILL <br />2 Ec' <br />M N p< <br />N Q co Z <br />U J <br />Z <br />U <br />❑❑❑❑ <br />W <br />� C) <br />Z N C)co O <br />co NN <br />p Q <br />M <br />d N <br />N <br />M <br />II <br />L <br />U <br />f� Y <br />w 0 <br />a <br />� a <br />O <br />t.n <br />° <br />W~ <br />o <br />� N <br />U M <br />w m <br />� � <br />�! <br />z <br />O y <br />O <br />U) N <br />, <br />sm <br />o <br />w <br />Mw <br />M <br />o <br />z <br />¢Z <br />=o <br />� <br />Ym <br />Qo <br />��=°o <br />H C <br />r¢ <br />o U <br />oQ <br />O <br />L4 <br />¢z <br />¢w¢o <br />wz <br />=3 <br />c <br />❑ <br />o' <br />.0 <br />O <br />Z <br />- (3) <br />" 2co <br />a w <br />z <br />¢ <br />o <br />ao <br />Q 3 <br />LL <br />�w <br />Uao <br />�_ <br />o <br />J <br />wF <br />�o <br />CZ)a= <br />Cfl <br />owp <br />Z Q <br />O~ <br />U <br />�N <br />0 <br />.N <br />>� <br />L <br />> <br />00 <br />c <br />00 <br />N <br />`° <br />J <br />O <br />Q <br />C U <br />0) <br />m <br />r*_ <br />Z <br />LO <br />O <br />T 00 <br />N <br />r <br />T <br />00 <br />co <br />T C) <br />Q <br />E <br />� <br />N <br />CM T- <br />y N <br />o <br />Z <br />Z <br />E Q <br />r <br />cc <br />d <br />E <br />U -1 <br />a :) <br />Q p <br />c <br />c <br />J <br />JOB <br />NO: <br />19-8536 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.