Laserfiche WebLink
0 <br />•U <br />J <br />CD <br />t7 <br />rn <br />N <br />0 <br />N <br />0 <br />0 <br />a. <br />rn <br />0 <br />N <br />N <br />0 <br />w <br />m <br />�y <br />Cn <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened., <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />f-t"lv <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />CL <br />?4 <br />FOUR-WAY SWITCH <br />,913 <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />1-0 <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />46 <br />TRACK LIGHT <br />>=--==< <br />FLUORESCENT LIGHT FIXTURE <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A INDOOR PANEL <br />CENTER <br />copper to lights & outlets <br />copper to 20 amp ckts <br />•2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />WITH CODE APPROVED <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />O EXHAUST FAN <br />;Ql EXHAUST FAN/LIGHT COMBINATION RECEPT. <br />�D VERIFY METER <br />ELECTRIC DOOR OPERATOR (OPTIONAL) FOR At <br />SYSTEM LOCATION WITH <br />CH CHIMES (OPTIONAL) BUILDER <br />19 PUSH BUTTON SWITCH (OPTIONAL) <br />FD PUSH BUTTON SWITCH - DOOR BELL <br />SD SMOKE DETECTOR <br />CO CARBON MONOXIDE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB TELEPHONE/USB (OPTIONAL) <br />© TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O THERMOSTAT <br />ELECTRIC METER <br />_JQ ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />NTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Gv�-- <br />I� <br />I <br />rn <br />0 <br />CV <br />0 <br />CV <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building <br />Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />Q <br />� <br />� <br />O co 8 <br />CD <br />N co ��p� <br />N## <br />ci <br />CD 0 0 CD <br />MNCV N <br />co J J <br />�m �LL <br />C <br />N <br />� J ` .� <br />J * <br />LL. J a Q <br />ei <br />LL N <br />M <br />� <br />Ll M � <br />to C N .— <br />m m O <br />W <br />z <br />�Eci�rn <br />�allo <br />10 °Q2 <br />=o�Q=e( <br />IL a <br />NQMZ <br />U 0 J g <br />Z <br />° ° <br />❑❑❑❑ <br />a W <br />M <br />Z N O <br />0 0 <br />zSO� <br />z o <br />J C) <br />� o <br />tJl <br />0 <br />N <br />0 <br />R3 <br />w <br />� a <br />U <br />Tom• <br />OT_ <br />Vj <br />W � <br />L E <br />Ln <br />® <br />v m <br />w m <br />O <br />= <br />co <br />W <br />co <br />Z <br />o <br />" <br />LJi <br />za <br />° <br />>� <br /><0_ <br />0- o <br />wI <br />z <br />Z® <br />o o: <br />CL <br />XO <br />O Q <br />0OU <br />0 � <br />Z <br />O E <br />O <br />04 <br />t <br />° o <br />¢ zo <br />o <br />¢¢o <br />"7 <br />• (p <br />=3C/) C <br />� <br />o U <br />m0 <br />r p <br />z W <br />Z <br />CID J <br />y0 <br />F <br />QW <br />z <br />° <br />Z <br />50 <br />W <br />a <br />a <br />a <br />Z <br />oc�i <br />w <br />ao <br />v <br />zja <br />° 3 <br />E O <br />0 <br />co <br />L <br />O <br />. <br />� <br />N <br />t° <br />O <br />C <br />OU <br />� <br />r <br />00 <br />0 <br />tN <br />O <br />O <br />N <br />r <br />ai <br />T <br />� N <br />cj N <br />^ <br />c <br />Z <br />M <br />Z <br />E O <br />m <br />Ry <br />c <br />a <br />o <br />U <br />2 ai <br />Q p <br />E <br />JOB <br />NO: <br />19-8531 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4.0 <br />