Laserfiche WebLink
a <br />p <br />e <br />CROSS BRACING DETAIL (TYP.) <br />SCALE: 1/2" = 1'4" <br />TRUSS NOTES: <br />CONV. FRAMED RIDGE <br />1. WOOD TRUSS ERECTOR SHALL PROVIDE BRACING ACCORDING TO ANSI/TP1-2002 <br />MAY BE NAILED <br />(TRUSS PLATE INSTITUTE) NOTE THAT THE COMBINED WIND AREA IS GREATER <br />W/ MIN. (4) 12d WHEN <br />BEFORE THE ROOF SHEATHING IS APPLIED, AND BRACING SHALL THEREFORE BE <br />IT LANDS NEXT TO <br />INSTALLED AS THE TRUSSES ARE ERECTED. INADEQUATE BRACING IS THE MOST <br />PRE-ENG. TRUSS — <br />COMMON CAUSE OF ACCIDENT IN WOOD TRUSS CONSTRUCTION. FULL BUNDLES <br />OF PLYWOOD SHALL NOT BE PLACED ON TRUSSES. THIS CONSTRUCTION LOAD <br />SHOULD BE LIMITED TO 8 SHEETS OF PLYWOOD ON ANY PAIR OF TRUSSES & <br />SHALL BE LOCATED ADJACENT TO THE SUPPORTS. NO EXCESS CONCENTRATION <br />OF ANY CONSTRUCTION MATERIAL (SUCH AS GRAVEL OR SHINGLES) SHALL BE PLACED <br />ON THE TRUSSES IN ANY ONE AREA THEY SHALL BE SPREAD OUT EVENLY OVER <br />A LARGE AREA SO AS TO AVOID OVERLOADING ANY ONE TRUSS. <br />2. ALL BRACING (DB,CB,BB) SHOWN ABOVE SHALL BE IN ADDITION TO CONTINUOUS <br />LATERAL BRACING SPECIFIED BY THE TRUSS MANUFACTER ALL LATERAL BRACING <br />SPECIFIED BY TRUSS MANUF. SHALL HAVE ADDITIONAL DIAGONAL BRACES AT 20'-0" <br />O.C. MAXIMUM. <br />3. ALL BRACES SHALL BE 2X4 NOMINAL DIMENSION LUMBER & SHALL BE ATTACHED W/ 2-16D <br />NAILS AT EACH TRUSS INTERSECTION. <br />4. ADDITIONAL BOTTOM CHORD BRACING SHALL BE INSTALLED AS REQUIRED BY TRUSS <br />DESIGN WHEREVER ADEQUATE STRUCTURAL CEILING ARE NOT <br />ATTACHED DIRECTLY TO THE BOTTOM CHORD OF THE TRUSS. <br />5. PROVIDE TRUSS BLOCKING AT ALL TRUSS BEARING SUPPORTS WHERE TRUSS <br />DEPTH EXCEEDS STANDARD HEEL HEIGHT. SEE TYP. TRUSS BLOCKING DETAILS <br />2X4 DIAGONAL AT 8'-0" O.C. 2X4 BLOCKING <br />BETWEEN EA. TRUSS <br />MAX & EACH END ALTERNATE A <br />DIRECTION TYP. <br />----/—WOOD TRUSS <br />A <br />TYP. WOOD TRUSS BLOCKING DETAIL <br />SCALE: 1 /2"=V-0" <br />WOOD WALL <br />OR TRUSS. <br />SEE PLAN <br />STRUCTURAL SHEATHING <br />ATTACHED PER NAILING <br />SCHEDULE <br />VARIES W/ <br />ROOF SLOPE <br />2X4 CONT. W/ (2) <br />16d COMMONS <br />NAILS EACH <br />STUD TYP. T&B <br />TRUSS OR <br />ROOF SYSTEM <br />SHEAR TRANSFER <br />EXTERIOR. WALL <br />SCALE: 3/4" = V-0" <br />CB <br />rri ­ j WM `, Wj i ill- v r a <br />TYP. HAND FRAMING ABOVE TRUSS <br />2X4 STUDS & PLATES AT 2'-0" O.C. <br />EACH DIRECTION TYP. U.N.O. <br />2x8 BLKING. NAILED @ EACH <br />SIDE w/ (3) 12d NAILS WHEN <br />REQUIRED w/ (2) USP HTW20 <br />W/ (14) - 10d X 1 1/2" EACH <br />B <br />TB <br />7 PRE-ENG. TRUSS <br />CONT. ROOF SHEATHING AT TRUSS TOP <br />CHORD AT ALL HAND FRAMED AREAS TYP. <br />DIAGONAL - <br />AT 8'-0" <br />MAX <br />WOOD <br />TRUSS <br />SEE ROOF <br />PLAN SHEATHING <br />2X4 BLOCKING <br />BETWEEN TRUSSES <br />SECT. A -A <br />G.T. <br />ADD 2X4 ALONGSIDE <br />TOP CHORD WHEN REQ'D <br />TO PREVENT PLYWOOD <br />SPAN FROM EXCEEDING <br />MAX 24" SPAN (EITHER <br />SIDE OR BOTH IF REQ'D) <br />PROVIDE 2X4 MIN. BLOCKING AT <br />rk OF HIP/RIDGE, TYP.BETWEEN <br />TRUSSES W/ (2) 12D NAILS EACH <br />END TO TRUSS TOP CHORD <br />TYP. <br />➢A TRUSS <br />K <br />HIP <br />G.T <br />(2) 12D NAILS — <br />AT 12" O.C. MAX <br />HIP/RIDGE BLOCKING DETAIL <br />VERTICAL SCAB <br />2 x 6 #2 SPF 48" O.C. <br />W/ (4) 10d TOP & <br />BOTTOM OR USP RT7 <br />OR HCLR/LL W/ 8 - 8d <br />IN PLACE OF (4) 10d <br />COLLAR TIE <br />EVERY 3rd <br />RAFTER <br />2X4 SPF 2 <br />(2) #7X 3-1/2" WOOD <br />SCREW EACH TRUSS <br />OR USP RT7 @ 48" O.C. <br />BEVEL CUTS <br />(OPTIONAL) <br />„ 2x8 #2 SPF RIDGE BEAM <br />* * 2x6 #2 SYP RAFTERS FOR SPANS 4FT <br />TO 8FT 2X4 RAFTERS FOR SPANS LESS <br />THAN 4FT @ 2'-0"O.C. MAX. w/ (3) 10d <br />COMMON TOENAILS TO RIDE BEAM <br />2X4 CONT. AT—/ CONC. MASONRY <br />T & B CHORD STEEL OR WOOD <br />BEARING SUPPORT <br />A —A ALTERNATE BLOCKING <br />DETAIL @ INTERIOR BEARING <br />SCALE: 1/2" = V-0" <br />PROVIDE BLOCKING AT ALL TRUSS BEARING <br />SUPPORT WHERE TRUSS DEPTH EXCEEDS <br />STANDARD HEEL HEIGHT <br />VARIES <br />ROOF SHEATHING <br />ATTACHED PER <br />2X4 #2 SPF BRACING @ NAILING SCHEDULE <br />16" O.C. W/ (4) 12d COMMON TRUSSES. <br />TOENAILS TO TOP SEE TRUSS PLAN <br />PLATE & (2) 12d END MIN. (2) 2x4 FOR CONNECTION <br />NAILS TO TRUSS FF EOp INFORMATION. <br />BOTTOM CHORD <br />VARIES SEE PLAN <br />FOR WALL LOCATION <br />a <br />MIN. 2X4 #2 SPF STUDS @ <br />v 16" O.C. W/ EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE & <br />(3) 12d TOENAILS TO <br />SEE PLAN FOR <br />PLATE BELOW <br />TOP OF WALL <br />o <br />MIN. 2x4 #2 SYP P.T. PLATE <br />°. <br />W/ 1/2"X8" EPDXY ANCHOR <br />MASONRY WALL SEE <br />@ 3" FROM EACH END & <br />PLAN FOR MORE <br />o <br />16" O.C. MAX. <br />INFO. <br />° <br />SECTION <br />@ ENTRY $ <br />SCALE: 3/4" = V-0" <br />USP LSTA18 <br />CENTERED @ <br />SPLIT TO TIE <br />BEAMS TOGETHER <br />SEE FLOOR PLAN <br />FOR COLUMN SIZE <br />& ADDITIONAL INFI <br />SCALE: 1 /2"=V-0" <br />USP HD4101F BUCK -- <br />SEE ROOF PLAN FI <br />MORE IN <br />(2) 2x8 #2 SYP W <br />7/16" O.S.B. FLIT <br />PLATE TOP @ TI <br />BRG. <br />TYPIC <br />WALL <br />NOTE: PENDING BEAM <br />BEARING LOCATION, THE <br />BEAM CAN SIT ON TOP OF <br />COLUMN W/ (2) HTW20 <br />STRAPS <br />USP JUS46 OR JUS461F <br />BUCKET TO COLUMN <br />SUPPORT COLUMN BUILT-UP <br />(2)-2x4's OR 4x4 W/ (2)-10d <br />NAILS @ 8" O.C. EACH PLY <br />(SHOWN AS 4 x 4) <br />(2) USP HTA20's <br />w/(10)-10d x 1 1/2 EA. TO COL. <br />ALT: (2) USP MSTAM36 <br />STRAPS CENTERED <br />w/(13)-10d NAILS Ea TO COL. <br />TIE BEAM <br />BEAM @ RAISED ENTRY <br />MASONRY WALL r4 <br />SCALE: 1/2" = 1'4' <br />SEE PLAN L. <br />FOR CANT. <br />SEE FLOOR PLAN FOR <br />COLUMN SIZE & BASE 7116" OSB FLITCH PLATE <br />CONNECTION INFO REQ'D ONLY WHEN <br />INDICATED ON BM. <br />7116" OSB FLITCH PLATE SEE FLOOR PLAN FOR SCHEDULE/PLAN <br />REQ'D ONLY WHEN COLUMN SIZE & BASE <br />OPTION A INICATED ON B. SCHEDULE/PLANM OPTION B CONNECTION INFO OPTION C <br />COMMON BM. TO POST ATTACHMENT <br />SEE ROOF PLAN <br />FOR BEAM SIZE & <br />CONNECTION INFO. <br />USP ST18 <br />TYP. U.N.O. <br />SEE FLOOR PLAN FOR _ <br />COLUMN SIZE & <br />ADDITIONAL INFO. <br />(WOOD COLUMN SHOWN) <br />2X4 STUDS W/ USP <br />SPT22 @ BASE SEE <br />J/S6 FOR MORE <br />INFO. <br />A r__� A <br />SEE PLAN FOR <br />SEE PLAN FOR <br />CANT. IF <br />INDICATED <br />O <br />O <br />CORNER SEE FOUNDATION <br />PLAN FOR MORE INFO <br />5" <br />COMMON BM. ATTACHMENT <br />SCALE: 3/4"=V-0" <br />EXTERIOR SHEATHING <br />ATTACHED PER <br />NAILING SCHEDULE <br />2X4 BASE PLATE W/ <br />USP LSTA30 OR <br />MTW12 TO FLOOR <br />GIRDER BELOW @ 16" <br />O.C. <br />16" FLOOR SYSTEM — FLOOR GIRDER <br />SEE PLAN FOR SEE PLAN FOR <br />DIRECTION CONNECTION <br />SECTION @ FLOOR <br />CONNECTION r22"� <br />SCALE: 3/4" = V-0" <br />SCALE: 3/4"=V-0" <br />SEE 1/S5 FOR <br />ADDITIONAL <br />OUTLOOKER <br />INFO. <br />ju <br />GABLE <br />TRUSS <br />1/2" PLYWOOD <br />(2) 16d NAILS TO <br />EACH COMMON <br />TRUSS/ FRAMING <br />TYP TOP & BOTTOM <br />BM. SPLICE OVER <br />CL ///,-- CENTER OF POST <br />MIDDLE <br />[— SEE PLAN FOR <br />8d NAILS AT VALLEY TRUSS <br />4" O.C. INFO. <br />MASONRY WALL BELOW: USP <br />HTA16 @ 4'-0" O.C. TO GABLE <br />MASONRY WALL TRUSS BEAM BELOW: USP <br />OR BEAM HTW20 @ 4'-0" O.C. TO GABLE <br />SEE TRUSS PLAN aTRUSS <br />COMMON TRUSS <br />'<. SEE ROOF PLAN <br />FOR CONNECTION <br />SECTION AT HIP GABLE 12 <br />SCALE: 3/4" = 1'-0" <br />EXTERIOR <br />ATTACHED <br />SCHEDULE <br />KNEEWALL <br />2X4 #2 SYP NAILER. NAIL TO STUDS W/3-16d @ <br />EA. STUD. TOENAIL EA. <br />TRUSS TO NAILER w/3-10d <br />JACK TRUSS (AS SHOWN) <br />OR GABLE END SEE TRUSS <br />LAYOUT <br />CLIP EACH TRUSS <br />(SEE ROOF PLAN <br />FOR TYPE) <br />FRAME OUT TO <br />BLOCK EDGE <br />SEE DETAIL 4/D1 <br />FOR BEAM SIZE <br />2x SPF #2 <br />AT 16" O.C. <br />BUILDER FRAME <br />RADIUS <br />AS REQUIRED <br />ENTRY FRONT WALL s <br />SCALE: 1/2" = 1'4' <br />USP JU26 OR IF 2 PLY ' <br />TRUSS USP JUS26-2 <br />TRUSS TO LEDGER <br />2X8 #2 SYP CONT. LEDGER w/ <br />(4) 16d NAILS ATTACH NAILS <br />INTO END OF EACH FLOOR <br />TRUSS, 24" O.C. MAX. (AT <br />EACH SIDE OF G.T. INSTALL <br />(4) NAILS EACH SIDE) <br />ROOF AND EXTERIOR <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />SEE 2ND FLOOR WALL SECTION <br />FOR ADDITIONAL INFORMATION <br />SEE FLOOR FRAMING <br />PLAN AND J/S6 FOR MORE <br />INFO. VERIFY WITH PLAN <br />FOR LOCATION AND <br />DIRECTION (IF PARALLE <br />SEE 2/D2 FOR BLOCKING <br />INFO) <br />-MASONRY WALL <br />(TYPICAL) <br />SECTION AT LOW ROOF <br />SCALE: 1/2" = 1'-0" <br />LOW ROOF/WALL <br />SHEATHING ATTACHED <br />PER NAILING SCHEDULE <br />2x STUDS @ 16" O.C. <br />W/ USP SPT22 @ <br />BASE & SPT24 @ TOP <br />2x BLOCKING BETWEEN <br />STUDS TO TRUSS W/ (2) <br />12d TOENAILS EACH END <br />( BETWEEN TRUSSES (2) <br />12d NAILS TO EACH <br />VERTIVAL STUD) <br />2x BASE PLATE W/ (2) 12d <br />NAILS @ 16" O.C. ALONG W/ <br />USP MTW12 TO BLOCKING <br />BELOW @ 16" O.C. <br />PLYWOOD <br />FLOORING <br />LOW ROOF TRUSS W/— L (2) 2x6 BLOCKING UNDER FLOOR G.T. <br />RAISED BOTTOM CHORD 2nd FLOOR WALL W/ USP SEE PLAN <br />EXTENSION SEE TRUSS JUS24-2 EACH END <br />MANUF. SPEC'S FOR <br />CONNECTIONS TO G.T. <br />SECTION @@ BUMP OUT 39 <br />SCALE: 3/4"= V-0" <br />DETAILS & SECTIONS <br />10 <br />0 <br />zo <br />IDz� <br />—0 <br />z <br />o <br />J <br />z <br />V) (h <br />Q) <br />C <br />i--d w <br />�U <br />- <br />12 <br />0 w <br />E <br />E <br />� <br />YZ <br />0 <br />co <br />M U <br />mco <br />vM <br />w <br />E <br />— q <br />c' m m <br />2-0m <br />O o0 <br />= dj <br />s U_ 00 <br />0, Q <br />1, <br />o <br />0 O V" <br />Q 0) <br />CL <br />0, Q O <br />®® <br />N C B D C <br />co <br />C4 <br />3 N <br />"7 <br />a <br />-91 <br />q. <br />LL <br />Cry - <br />�yqN��OG��^`' <br />al <br />UM W N 0 <br />I <br />f <br />+J <br />~W��� <br />�s E S S <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />� o <br />►>M � C)Q�_LO <br />a .L <br />n <br />L_ Ln <br />Q U_ <br />�M <br />QU a00 <br />Z E <br />W O <br />Uj J <br />d- <br />oz <br />=o <br />�o <br />Za <br />z g <br />i¢ <br />U,00 <br />r_�0 <br />C,U <br />FU Z Q <br />==WZ <br />2�ui <br />J <br />T� <br />UU W � N <br />W <br />cn <br />mow° <br />o(n <br />Z z <br />0 <br />}o <br />az <br />> <br />,--I <br />ZW <br />CL <br />U <br />� <br />2: <br />M <br />w <br />M <br />O <br />-0 <br />06 <br />o <br />Z <br />U <br />C!) <br />J <br />ou_ <br />¢�¢0 <br />o <br />J <br />Q <br />x,0U <br />W <br />U r m <br />a -oa <br />T <br />N <br />I� <br />Q <br />Z¢a <br />W Q J <br />;Q¢Q <br />Q <br />aow� <br />-En <br />Z <br />Sao <br />LU <br />J <br />Lr) <br />,--I <br />W <br />=5QC�= <br />0 8 <br />W <br />0 W U <br />0 Y Q <br />q <br />Ln <br />¢ <br />Z <br />z <br />�Ujo <br />Q,Z <br />IT <br />as <br />�Ln <br />J [1 <br />0 <br />= <br />Ln <br />az <br />SCALE: AS NOTED <br />DATE ; 2/24/2014 <br />TECH: ERAND <br />VERSION N0. 10 <br />SHEET NO. <br />D1 <br />