Laserfiche WebLink
gD <br />DO NO' <br />BOTTO <br />FI mini <br />SELF -ADHERED FLASHING <br />HALF ROUND WINDOW <br />I L Ql IIIVV FL Q[l11VV <br />SELF -ADHERED FLASHING <br />DECK JOIST <br />2x FRAMEWALL <br />TILE FINISH- <br />1/2" DUROCK- <br />8" CMU <br />1'4" PER PLAN <br />1'-0" PER PLAN <br />4"OR8"CMU - <br />(PER SEAT DEPTH) ° <br />FILL WITH GROUT <br />d ° d <br />° d n <br />SLOPED MUD BED ° <br />n d <br />VINYL SHOWER PAN ° 4 d , <br />SLOPE <br />d <br />'I a <br />a � a <br />a <br />a <br />SHOWER SEAT <br />L <br />SECTION -A (SEE DETAIL <br />4SHING <br />SELF -ADHERED FLASHING <br />1 <br />2 SEAL TOPS OF JOISTS <br />UNDER DECKING <br />8 (SEE DETAIL WP07) <br />SELF-ADHEF <br />0 <br />SELF -ADHERED FLASHING <br />EXTERIOR DOOR WITH DECK <br />SELF -ADHERED FLASHING <br />OUTSIDE CORNER <br />Q <br />w <br />m <br />Q <br />Z <br />g g <br />LU d PLASTER STOP <br />= W CONTINUOUS BACKER <br />Lu ROD & SEALANT <br />W Lu <br />2 � <br />Q Cr <br />Lu <br />� ° A <br />2 8 <br />SELF -ADHERED FLASHING <br />PATCH <br />HERED FLASHING <br />1 <br />2 <br />4 <br />5 <br />STRIP OF SAF <br />DRAINAGE PLANE WRB <br />BOND BREAK WRB <br />SF LATH <br />{ WRAP DP WRB ONTO <br />/ THE VERTICAL <br />SURFACE TO TOP OF <br />FLANGE AS AN AIR <br />BARRIER <br />3-1/2" INCH FLANGE <br />r� THIS GAP IS A RESUL <br />NATURAL SHRINKAGI <br />DO NOT SEAL. <br />\-- DRIP SCREED PLASTI <br />ACCESSORY <br />me <br />a <br />SOFFIT/CANTILEVER <br />1 <br />O <br />SELF -ADHERED FLASHING <br />INSIDE CORNER <br />-7 Ground <br />Water Resistant Barrier <br />Lath <br />Sheathing <br />Stucco <br />FOUNDATION WEEP SCREED <br />LEGEND <br />SELF ADHERED FLASHING (SAF) -Q o <br />DRAINAGE PLANE (DP) WEATHER RESISTANT <br />BARRIER (WRB) <br />BOND BREAK WEATHER RESISTANT BARRIER - <br />SELF FURRING (SF) LATH <br />PLASTER ACCESSORY <br />SHEATHING,'OSB', PLYWOOD, DENSGLASS <br />TRUCTURAL FRAMING <br />TRUCTURAL SHEATHING <br />TRIP OF SAF <br />RAINAGE PLANE WRB <br />OND BREAK WRB <br />F LATH <br />FLASHING REQUIREMENTS <br />R609.1 Flashing, Sealants and Weatherstripping. Flashing and sealants for exterior windows shall comply with Section R703.8. <br />R703.2 Weather -resistant sheathing paper. One layer of No.15 asphalt felt, free from holes and breaks, complying with ASTM D 226 for Type 1 felt or <br />other approved water -resistive barrier shall be applied over studs or sheathing of all exterior walls. Such felt or material shall be applied horizontally, <br />with the upper layer lapped over the lower layer not less than 2 inches (51 mm). Where joints occur, felt shall be lapped not less than 6 inches (152 <br />mm). The felt or other approved material shall be continuous to the top of walls and terminated at penetrations and building appendages in a manner <br />to meet the requirements of the exterior wall envelope as described in Section R703.4 <br />Exception: Omission of the water -resistive barrier is permitted in the following situations: <br />1. In detached accessory buildings. <br />2. Under exterior wall finish materials as permitted in Table R703.4 <br />3. Under Paperbacked stucco lath when the paper backing is an approved water -resistive barrier. <br />R703.4 Flashing. Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into thewall cavity or <br />penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The <br />flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashings shall be installed at all of the following locations: <br />1. Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of he exterior wall finish or to the <br />water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with one or more of the <br />following or other approved method: <br />1.1 The fenestration manufacturer's written flashing instructions. <br />1.2 The flashing manufacturer's written installation instructions. <br />1.3 In accordance with FMA/AAMA 100, FMA/AAMA 200, or FMA/WDMA 250. <br />1.4 In accordance with the flashing method of a registered design professional. <br />2. At the intersection of chimneys or other masonry construction with frame or stucco walls, with projecting lips on both sides under stucco copings. <br />3. Under and at the ends of masonry, wood or metal copings and sills. <br />4. Continuously above all projecting wood trim. <br />5. Where exterior porches, decks or stairs attach to a wall or floor assembly of wood -frame construction. <br />6. At wall and roof intersections. <br />7. At built-in gutters. <br />R703.6.2.1 Weep Screeds <br />A Minimum 0.019-inch (No. 26 Galy. sheet gage), corrosion -resistant weep screed or plastic weep screed, with a minimum vertical attachment flange of <br />3 1/2" shall be provided at or below the foundation plate line on exterior stud walls in accordance with ASTM C 926. <br />SELF -ADHERED FLASHING <br />PRODUCTS DETAILS <br />TWO LAYERS OF FELT OR ONE LAYER OF HOUSE WRAP AND <br />ONE LAYER OF FELT ARE REQUIRED BEHIND STUCCO. FBC R703.2.1 <br />Detail Instructions <br />Refer to the number marked as G in each detail that corresponds to the numbered items in the list of <br />instructions below: <br />1. Install self -adhered flashing in order as shown by numbers <br />2. Install flashing and weather resistive barrier to form water shedding laps <br />3. Self -adhered flashing can be substituted for building paper <br />4. Split the release paper using the ripcord (Split release on demand, embedded in the adhesive layer) - <br />for ease of installation and to minimize scoring cuts <br />5. Remove all release paper per standard installation instructions and adhere to substrate using a square <br />piece of flashing material (6" x 6" Minimum) <br />6. Fold as shown by arrows <br />7. Angle of corner may vary, adjust folding of the flashing accordingly to fit tight to corner <br />8. Mechanically fasten as necessary <br />pp'pp.❖.; !a. <br />age <br />;r•; •: •::,I <br />y� <br />4.' <br />_ 7 <br />1 <br />Cement Plaster <br />in accordance <br />with ASTMC926 <br />over wood 2nd <br />floor <br />Cement <br />Plaster <br />over block <br />1 st floor <br />7/8" Cement Plaster <br />�- in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />/- Building Paper <br />_---7/16" O.S.B. <br />sheathing <br />Metal <br />Flashing <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />Maintain . <br />Bottom of <br />Weep Screed <br />1 1/2" to 2" <br />Above Roof <br />Sheathing <br />Note: <br />The building paper and metal lath must be <br />installed over the top of the weep screed. <br />WEEP SCREED DETAIL <br />SCALE: NOT TO SCALE <br />7/8" Cement Plaster <br />in accordance with <br />ASTMC926 <br />Felt backed metal <br />lathe in accordance <br />with ASTMC1063 <br />Building Paper <br />7/16" O.S.B. <br />sheathing <br />.Stampede or similar <br />cauk bottom <br />joint only <br />Weep Screed <br />Installed As Per <br />Manufact. Specs. <br />1/2" Cementitious <br />Decorative Finish <br />All inside and <br />outside corner will <br />need to be miter <br />cut and caulked all <br />butt joints need to <br />becaulked using <br />Stampede or sim. <br />caulk for all <br />r <br />rD <br />r� <br />rn <br />0 <br />N <br />0 <br />N <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />w <br />,. <br />V <br />O U <br />0� <br />N r 'o <br />N e� <br />� <br />= <br />O O O ✓T <br />cl) N N = <br />qk <br />cp <br />00 In N LL LL <br />C <br />�Ma <br />LL <br />_1 * Lu W <br />LL LL a s <br />41 M <br />iy <br />W O a <br />tl d = Y <br />ow <br />mmo <br />W <br />Imo <br />= NIL - <br />mor­'r <br />mM <br />2 <br />a <br />Z <br />Z <br />LL <br />0)2 E� rn <br />_«o r- <br />N Q M Z <br />X o g <br />X rn x <br />C Z <br />Z <br />° <br />U <br />0000 <br />W <br />z N S <br />z " <br />J M <br />o <br />M <br />N <br />z <br />o <br />N <br />_0 <br />4--J <br />w - <br />U � <br />O <br />to <br />` <br />c E <br />o <br />� <br />� <br />V M <br />w MI <br />O $ <br />I <br />_® <br />= <br />-jas <br />m <br />�� <br />o <br />Co <br />J <br />W <br />co <br />co <br />z ¢ <br />o <br />z <br />zQ <br />J <br />L <br />Q E <br />� <br />z o <br />�� <br />wE <br />,m <br />Z® <br />on <br />- C <br />O <br />o <br />Xo <br />� <br />s <br />ap <br />wo <br />noo <br />o <br />O� <br />z <br />cli <br />N L <br />¢o <br />�Z <br />v <br />Y <br />�m <br />n0 <br />Z � <br />aw <br />Zz <br />N <br />oa <br />ao <br />W <br />ao <br />oLL <br />�3 <br />O <br />>0 <br />CO <br />w <br />zl¢ <br />a x <br />=N <br />0 <br />.N <br />> cj- <br />^L' <br />W <br />'> <br />cu <br />00 <br />co <br />CV <br />coJ <br />O <br />o <br />O <br />A, m <br />� <br />W <br />O <br />r <br />M. <br />0) <br />r <br />_ <br />T <br />Z r- <br />o <br />LO <br />r <br />.L <br />j N <br />M <br />r <br />CN <br />_ <br />Z <br />Z <br />E <br />r <br />a <br />0 � <br />¢ o <br />JOB <br />NO: <br />19-8535 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />W P <br />