My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3152 Nubbin Ridge Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3152 Nubbin Ridge Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 4:19:03 PM
Creation date
2/19/2025 8:54:41 AM
Metadata
Fields
Template:
Building Plans
Street #
3152
Location
Nubbin Ridge Ln
Contractor
Lennar Homes
Building Plans - Permit #
22334
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />1GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />POWER CO. <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />200A <br />INDOOR PANEL <br />CENTER <br />10 #14 Copper to lights & outlets <br />NEMA 1 <br />200 AMP <br />10 #12 copper to 20 amp ckts <br />01 #10-2 copper to WH <br />10 #10-3 copper to Dryer <br />METER <br />MAIN <br />O/0 <br />or <br />4/0 SER Alu <br />200 amp <br />IT <br />150 amp <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />WP GFI DISC. <br />H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn nco oncr+c <br />lO <br />EXHAUST FAN <br />I -- <br />j <br />WH. VERIFY LOCATION <br />-. <br />�Or <br />EXHAUST FAN/LIGHT COMBINATION <br />GFI <br />-- _ _ _ _ _ _ _ _ J <br />ELECTRICAL PANEL <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RECEPT. <br />CH <br />CHIMES (OPTIONAL) <br />FOR ALARM VERIFY METER <br />PB <br />PUSH BUTTON SWITCH (OPTIONAL) <br />SYSTEM LOCATION WITH <br />BUILDER <br />H <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />512 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />I <br />ELECTRIC METER <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G ' J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />ELECTRICAL PLAN - ELEV-B1 <br />SCALE: %4"=1'-0" <br />RJUI <br />ED <br />Imo`' <br />I� <br />m <br />0 <br />N <br />o_ <br />N <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />N <br />f' <br />Q <br />avpE <br />_ 8 <br />o 4 <br />ip0) <br />N_ ~ V� <br />N <br />01 <br />M N r- N <br />00 LL LL <br />O <br />..U+ Cl)Q) N <br />gu- <br />J# W Lu <br />LL -1 d (L <br />13 10 <br />LL <br />6 cc"')Ll <br />LL. <br />Lu j <br />Lu <br />� <br />mS? o <br />I6CC <br />-in <br />onma� <br />m❑ <br />C <br />1 2 Earn <br />g❑0 <br />Z <br />N M<Z <br />< <br />°IL <br />Z <br />❑❑❑❑ <br />41 <br />(D <br />� <br />z o <br />� o <br />ao N <br />o <br />z <br />� <br />Q <br />J (h <br />O <br />E3 <br />!Z Pi <br />N <br />z <br />� o <br />C1 <br />N <br />_ LL <br />V) Y <br />w 0 <br />n <br />U o a <br />OW <br />N <br />E <br />0. <br />� V <br />� pp o <br />rn <br />71;0_Z-Z1 <br />v o <br />c U) <br />o <br />� <br />Q- p <br />E <br />zo <br />�O <br />oz <br />zo <br />QN <br />?© <br />u <br />co <br />QZS <br />oo, <br />H <br />�U <br />a� <br />UO <br />oU <br />U <br />o E <br />tV <br /><z <br />o <br />G <br />wz <br />w <br />L <br />ro <br />U) ❑ <br />C <br />❑ <br />o U <br />y <br />m 0 <br />o <br />O � <br />� <br />J <br />m <br />a ° <br />Q W <br />Z z <br />on <br />ai <br />w <br />o <br />OLL <br />Z <br />5° <br />W <br />U <br />a <br />1G <br />-o <br />o Z <br />TO <br />o <br />Qa <br />10 <br />Za <br />¢ <br />UU3 <br />=N <br />0 <br />^L' <br />W <br />'co <br />r <br />c <br />N <br />O <br />cYi <br />CA <br />v1/ <br />� <br />TZW <br />c <br />T- <br />o � <br />C� <br />T <br />Z o <br />LO <br />y r <br />CN N <br />C) <br />T <br />T <br />CM <br />o <br />ca <br />Z <br />E O <br />,— <br />d <br />U J <br />Q <br />J <br />JOB <br />NO: <br />19-8532 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.