Laserfiche WebLink
r <br />n <br />12 <br />5� <br />Z TEXTURED B ND <br />—7 ■ ■ ■ ■ ■ ■ ■ ■ ■ �A� <br />�❑■ 0 ■0 0■ 0 ❑� 0 ❑■ II•I III <br />IFEIN I000a000_ <br />I� I� l� IlIN IFM71�I <br />16-0" RIDGE VENT <br />3'-0 RIDGE VENT <br />12 <br />�5 <br />FRONT ELEVATION - Al <br />SCALE: 1 /4"=V-0" <br />LEFT ELEVATION - Al <br />1 /4"=1' <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />.G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER, <br />"ELECTRICAL SPECIFICATION NOTES" <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following, <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code I Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />—CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA! LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFITVENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />� a <br />0 <br />m <br />N <br />z o <br />z <br />0= N <br />V)IL <br />� w <br />O w T <br />N c E <br />t/' S. <br />t11ls <br />o <br />U <br />w <br />o g <br />I <br />�l <br />_ :F; ai <br />:) o us <br />Q <br />rn rn <br />4m <br />N <br />N <br />yy a� o <br />Z Zo <br />a;Mw a <br />A/ C2 r` o U 1 W 1` <br />LU mLL .O k zz <br />o o <br />Z 0 � <br />o <br />Unz <br />Wes= N <br />a� tj 3 I_ El-C3 <br />a . G'\ <br />J<� <br />-. <br />� t <br />P �• <br />t <br />0FESS0 <br />.. <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />C:,W <br />co <br />CIDw¢Z <br />oS <br />Z <br />z <br />� <br />IJI- <br />C6 E <br />ca- p <br />zo <br />oo <br />>m <br />® <br />E u <br />(LS <br />a= <br />20. <br />XU <br />UO <br />�U <br />O <br />ZI— <br />G <br />O C <br />O <br />C14O <br />a <br />� z <br />0 <br />¢ <br />�z <br />W <br />L <br />(a <br />C <br />z <br />Z <br />Y <br />m 0 <br />O <br />oz <br />C> <br />J <br />Cl)tiw <br />c"m <br />zm <br />zz <br />� 3 <br />Q <br />od <br />� <br />g0 <br />a <br />NW <br />W <br />w <br />3 <br />O <br />yz <br />�� <br />7� <br />irp <br />co <br />�t <br />i= w <br />zl¢ <br />I a <br />OUP <br />C C:)O <br />.N <br />^L, <br />W <br />> <br />CN <br />� <br />ty <br />c <br />1 - <br />N <br />c� <br />N <br />�C j� <br />1TT� <br />V, <br />Z TO <br />T-- <br />V) <br />r <br />T N c;1 0404 <br />T— <br />z <br />M 0 <br />� N r' <br />o <br />z <br />O <br />E <br />03 <br />f° <br />d <br />o v m <br />U _J Q p <br />aci <br />JOB <br />NO: 19-5900 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.1 <br />