ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />GENERAL ELECTRICAL NOTES: <br />Notes: unless otherwise noted, <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />13 <br />THREE-WAY SWITCH <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />—� <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O EXHAUST FAN <br />;OEXHAUST FAN/LIGHT COMBINATION <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH CHIMES (OPTIONAL) <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD SMOKE DETECTOR <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />® TELEVISION (OPTIONAL) <br />®2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60"A.F.F. <br />O THERMOSTAT v SYSTEM BUILDEIRN WITH <br />T <br />ELECTRIC METER <br />mpg_ ELECTRIC PANEL <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 08, 250.94 —/ <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />VW to egna &outlet <br />spper to 20 arrp ane <br />copper to WH <br />copper to Dryer <br />t Alu <br />Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />WP DISC. <br />GFI H.I <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />unnn nffn onr-nc <br />MELJ <br />DISCONNECT SWITCH <br />® <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />c� <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />< J <br />OPT. CEILING FAN <br />09 <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Ln <br />Z o <br />— co <br />Z <br />Q <br />O <br />J <br />u, Z <br />nV)' <br />Q) u) <br />W <br />0 <br />U <br />0 w <br />� <br />I— <br />C <br />o <br />(� <br />0 0 <br />in CN <br />U <br />uJ <br />a) M <br />CM M <br />— U <br />WW ~° <br />°0N <br />= N <br />U <br />L LL CO <br />a°'i <br />CY <br />a o <br />V7 O� <br />Qrn <br />rnQo <br />A , <br />B I <br />DC <br />NCBV <br />*I <br />'r I <br />O <br />N <br />N_ <br />tp N <br />�Cj <br />a <br />N o�co0a, �Z <br />o N <br />cli <br />ao <br />o <br />0 <br />Z W C)Nr-Z —_ <br />II• p: V, cp C ti <br />=LL;O Ow� <br />z <br />J <br />IlY <br />W _ .6M N <br />C <br />a W <br />ZV Q $� fi <br />Z <br />IA y p C N <br />V <br />us Z <br />CID <br />m <br />CN 8 <br />0 <br />W N Q P7 <br />0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z r-t <br />O <br />� kD <br />O <br />QU)(0to <br />d- <br />Q U_ <br />U fu <br />Z <br />Z § E­ <br />fa <br />Z <br />WJ <br />l00 <br />0 <br />�R <br />3 <br />� w <br />Za <br />fa <br />Z <br />Qua <br />r~00 <br />Hj <br />J <br />U <br />0�oZ <br />U <br />off® <br />L <br />Z O <br />^, <br />V ) <br />< V <br />w <br />a <br />a <br />M <br />w <br />8 <br />1 <br />O <br />M <br />fa <br />_ <br />O <br />0 <br />LL <br />J Q <br />> <br />0 <br />J <br />Y r- <br />UU <br />r4 <br />Q <br />Z!iod <br />1 ` <br />� <br />Lu Q � <br />Z <br />^ <br />Fz <br />50�� <br />M-2 <br />W <br />LP) <br />� W, � <br />J <br />Q <br />(L <br />Q <br />Z <br />a u_ 0 <br />0 o <br />Q <br />,u F- I- <br />eLuZ <br />Ln <br />7—I <br />*k <br />Ln <br />Z <br />tu— <br />Z <br />Z <br />W <br />aV) <br />� <br />f <br />*..I <br />(= <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: M]AMES <br />VERSION N0. 10 <br />SHEET NO. <br />4.0 <br />