3186 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3186 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 8:39:26 PM
Creation date
2/19/2025 8:56:43 AM
Metadata
Fields
Template:
Building Plans
Street #
3186
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19068
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I CORNER OF <br />HOME <br />GARAGE SIDE <br />10'-0" <br />TANK -LESS W/H <br />H C G <br />0 0 0 <br />01 <br />5'-0" <br />STUB -OUT FOR O <br />GAS METER - 0 <br />0 0 <br />tV _ <br />• MEASUREMENTS ARE FROM FINISHED FLOOR <br />• ROUGH -IN GAS TO RIGHT (ALWAYS) -12" OFF -CENTER <br />• ROUGH -IN ELECTRIC TO LEFT (ALWAYS) -12" OFF -CENTER <br />GAS CONNECTION DETAIL <br />"ONLY APPLIES TO HILLSBOROUGH AND PASCO COUNTY" <br />RAFTER SPAN TABLE <br />MEMBER SIZE AND SPACING <br />MAXIMUM LENGTH <br />MEMBER CONNECTIONS* <br />2" X 4" @ 16" O.C. <br />T-5" <br />(2)16d TOENAILS <br />2" X 6" @ 16" O.C. <br />10'-8" <br />(2)16d TOENAILS <br />2" X 8" @ 16" O.C. <br />13'-9" <br />(3)16d TOENAILS <br />2" X 10" @ 16" O.C. <br />16'-5" <br />1 USP HTW20 OR 3 16d TOENAILS <br />2" X 12" @ 16" O.C. <br />19'-3" <br />(1) USP HTW20 OR (4)16d TOENAILS <br />2" X 4" @ 24" O.C. <br />6'-111 <br />(2)16d TOENAILS <br />2" X 6" @ 24" O.C. <br />8'-6" <br />(2)16d TOENAILS <br />2" X 8" @ 24" O.C. <br />11'-0" <br />(2)16d TOENAILS <br />2" X 10" @ 24" O.C. <br />13'-U' <br />(3)16d TOENAILS <br />2" X 12" @ 24" O.C. <br />15'4" <br />(1) USP HTW20 OR (3)16d TOENAILS <br />* TOENAIL CONNECTIONS DESIGNED FOR SHEAR ONLY (i.e. RAFTER TO RIDGEBEAM). <br />** SOUTHERN YELLOW PINE, 55 PSF LOADING <br />w <br />co <br />ROOF DIAPHRAGM NAILING SCHEDULE <br />RInGF I INF <br />+ + <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + 4 <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + + +ZbD <br />+ + + + + + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + + <br />+ + + + + + + + + + + + + + <br />+ + <br />+ + <br />+ <br />+ <br />+ + <br />, ,, <br />+ <br />+ <br />+ + +4 <br />+ + <br />+ + <br />++ <br />+ <br />+ <br />+ <br />+ + + + + + + + <br />+ <br />+ + + + + + + + + + + <br />+ + <br />+ + <br />+ + + + + + + 4 <br />+ + <br />+ + + + + + + + + + <br />+ <br />+ <br />+ + + + + + + + CO <br />+ <br />+ + + + + + + + + + + <br />+ + <br />++ <br />+++ <br />++++++++ <br />+ <br />I <br />15/32" CDX <br />PLYWOOD OR <br />7/16" OSB <br />IDGE LINE <br />140 MPH (ult)3 SECOND GUST EXPOSURE "C" WIND ZONE 140 MPH (ult) 3 SECOND GUST EXPOSURE "C" WIND ZONE <br />8d RING SHANK NAILS @ 6" O.C. & 8d RING SHANK NAILS @ 6" O.C. EDGES & <br />+ + + + + 4" O.C. @ GABLE END WALL OR GABLE TRUSS 8d RING SHANK NAILS @ 6" O.C. INTERMEDIATE <br />0.113 INCH NOMINAL SHANK DIAMETER 0.113 INCH NOMINAL SHANK DIAMETER <br />RING DIAMETER OF 0.012 OVER SHANK DIAMETER RING DIAMETER OF 0.012 OVER SHANK DIAMETER <br />16 TO 20 RINGS PER INCH 16 TO 20 RINGS PER INCH <br />0.280 INCH FULL ROUND HEAD DIAMETER 0.280 INCH FULL ROUND HEAD DIAMETER <br />2 INCH NAIL LENGTH 2 INCH NAIL LENGTH <br />NOTE: rFOR 8d RING SHANK NAILS 0.113x 2x 3/8" RING SHANK COIL GUN NAILS MAY BE USED <br />1) SEE STRUCTURAL NOTES FOR SHEATHING SPECIFICATIONS AND WIND SPEED. <br />2) END JOINTS OF THE ROOF SHEATHING SHALL BE STAGGERED AND OCCUR OVER FRAMING MEMBER. <br />3) SCHEDULE ASSUMES SHEATHING IS FASTENED DIRECTLY TO SOUTHERN YELLOW PINE OR DOUGLAS FIR OR BETTER, IF ROOF FRAMING CONSISTS <br />OF A LESSER GRADE OF LUMBER, CONTRACTOR MUST CONTACT ENGINEER OF RECORD FOR ALTERNATE NAILING PATTERN. <br />Backer and Filler Block Dimensions <br />BCI®Joist <br />Backer Block <br />Series <br />Thickness <br />Filler Block Thickness <br />3/4" or 7/8"Two <br />5000s 1.8/1.7 <br />wood panelel s <br />3/4" wood panels or 2 x _ <br />1-1/8" or two 1/2" <br />6000s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />6500s 1.8/1.7 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />1-1/8" or two 1/2" <br />602.0 <br />wood panels <br />2 x — + 5/8" or 3/4" wood panel <br />902.0 <br />2 x — lumber <br />Double 2 x — lumber <br />DOUBLE JOIST CONSTRUCTION <br />(Not required if both loaded equally from above) <br />Filler blocking <br />1/8" gap <br />4. <br />FILL CELL <br />STD. 90" HOOK BOND BEAM <br />W <br />j STD. 90* <br />CONT. #5 <br />CONT. #5 <br />BAR HOOK <br />BAR <br />#5 CONT. <br />FROM <br />FOUNDATION <br />TO HIGHEST <br />F_ <br />BOND BEAM <br />!/ BOND BEAM STEP <br />SCALE: N.T.S. <br />2nd FLOOR <br />INTERIORIEXT WALL SEE <br />PLAN FOR MORE INFO <br />CONT. BASE PLATE <br />BEARING COLUMNAblock <br />PLYWOOD FLOOR <br />SEE PLAN FOR REQSHEATHING PER PLAN <br />COLUMN AND <br />CONNECTIONTJI TO BE CUT TO ALLOW <br />FOR BLOCKING/TJI <br />MASONRY WALL OR <br />INTERIOR BRG. WALL <br />TJI PER PLAN <br />OTHERWISE SOLID <br />BLOCKING TO MATCH <br /># OF 2nd FLOOR <br />above to bearing below. STUDS <br />SECTION @ INT. BRG. WALL <br />N.T.S. <br />1/8" min. }Small gap 2" min. <br />4 max. <br />I <br />Clinch nails <br />when <br />lk�e� possible <br />1) Support back of web during nailing to prevent damage to <br />web -flange connection. <br />2) Block solid between joists for full length of span. Tight fit <br />3) Leave 1/8" gap between top of filler blocking and bottom of top flange. <br />2x4/Plywood/OSB web stiffener 2" min. <br />4) Place joists together and nail from each side with 2 rows of 10d nails 4., <br />Web Stiffener Fastener Schedule <br />Joist Bearing Location <br />Series Depth I End Intermediate <br />® <br />BCI5000s <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d- <br />BCI6000s® <br />BCI6500s® <br />9-1/2" <br />11-7/8" <br />2-8d <br />2-8d <br />2-8d <br />3-8d <br />14" <br />2-8d <br />5-8d <br />16" <br />2-8d <br />I 6-8d <br />BCI60e <br />11-7/8" <br />2-8d <br />I 3-8d <br />14" <br />2-8d <br />I 5-8d <br />16" <br />2-8d <br />6-8d <br />BCI90s® <br />11-7/8" <br />3-16d <br />3-16d <br />14" <br />5-16d <br />5-16d <br />16" <br />6-16d <br />6-16d <br />2x :CONTRACTOR TO PROVIDE 2x TO FILL THE HEIGHT <br />at 12" o.c., clinched when possible. Stagger rows from opposite <br />required when indicated or <br />- Hangers with side nailing. <br />max. <br />OF THE JOIST ASA REQUIRED LEAVINGY" GAP @ TOP <br />sides by 6". <br />- Hangers with sides not containing <br />WEB STIFFENER <br />top flange of Joist. <br />DOUBLE JOIST CONNECTION <br />- Birdsmouthcuts. <br />N.T.S. <br />- Under 2nd floor column w/ loads <br />N.T.S. <br />higher than 15001b. <br />BLOCKING INTERIORa <br />SQUASH BLOCKS AT INTERIOR <br />Boise Joist Blocking <br />transfer bea n wall <br />P g 9 <br />BEARING <br />Vertical load transfer =1900 plf max along load bearing wall. <br />Use 3" (1 Od) nails at 6" o.c. <br />Load bearing walls <br />Required on interior walls : - for vertical load transfer <br />when load bearing - for lateral support when joists <br />meet over wall, or wall stacks directly over wall or <br />Load bearing wall must stack <br />Plumbing <br />over squash=20 blocks and beam below Load bearing wall must stack over <br />require additional <br />Non -stacking walls wall or beam below" blocking and wall or beam below.* <br />consideration. Check /_f <br />� Joist <br />local building When joists meet over wall, provide <br />r1 3/4" minimum bearing for each. I -Joist can be offset <br />code for appropriate g <br />details in One 10d box <br />areas=20 of high or-20 sinker <br />lateral load. nail each side <br />at bearing. <br />Squash block <br />(2x4 minimum) <br />Bearing wall, Versa -Lam LVL or <br />Glulam Beam 0 —/ <br />NO HOLES (EXCEPT <br />KNOCKOUTS) ALLOWED <br />IN BEARING ZONES --, <br />DO NOT cut, notch <br />or drill flanges <br />j, Q"' Provide adequate bearing for each lapped joist. Use 10dx3" nails at 6"o:c. for all joist <br />j <br />blocking panel *Non-sWcking walls <br />10dnails SECTION @ INT. BRG. WALL require additional consideration.— <br />N.T.S. <br />MINIMUM SPACING = 2x GREATEST <br />D DIMENSION OF LARGEST HOLE <br />(see table below) (KNOCKOUT EXEMPTS) D <br />(see table below) <br />to <br />6n A iY" ROUND HOLE MAY A 611611NOTCUT HOLES <br />BE CUT ANYWHERE IN CANTILEVERIDO <br />LARGER THAN 1Y' <br />THE WEB, PROVIDE AT ROUND IN <br />LEAST 3" OF CLEARANCE CANTILEVERS. <br />FROM OTHER HOLES <br />MINIMUM DISTANCE FROM SUPPORT, LISTED BELOW IS REQUIRED FOR ALL HOLED GREATER THAN %" <br />� r � •^.� ��+ -� r �`" ' � �,$ ryas... a <br />� <br />�, �. <br />f . <br />� <br />'v� a. <br />3 <br />g "r' <br />� �' i^`� 2. <br />s� � <br />' y �.y r�- �',. <br />� '"�" 5�f <br />� � �. <br />- <br />IIIIIIII <br />NOTES: <br />1. JOISTS MUST BE PROPERLY DESIGNED M MEET BUILDING CODE REQUIREMENTS. <br />2. TABLE IS FOR UNIFORMLY LOADED MAXIMUM LOADS OF 40 PSL(LIVE) AND 15 PSF (DEAD) ON SIMPLE SPAN APPLICATIONS ONLY. <br />3. REFER TO JOIST SPECIFIER GUIDE FOR INSTALLATION AND OTHER INFO. <br />4. SELECT A TABLE ROW BASED ON JOIST DEPTH AND THE ACTUAL JOIST SPAN ROUNDED UP TO THE NEAREST TABLE SPAN. SCAN ACROSS <br />THE ROW TO THE COLUMN HEADED BY THE APPROPRIATE ROUND HOLE DIAMETER OR RECTANGULAR HOLE SIDE. USE THE LONGEST SIDE OF <br />A RECTANGULAR HOLE. THE TABLE VALUES IS THE CLOSEST THAT THE CENTERLINE OF THE NEAREST SUPPORT. <br />5. THE ENTIRE WEB MAY BE CUT OUT. DO NOT CUT THE FLANGES. HOLES APPLY TO EITHER SINGLE OR MULTIPLE JOISTS IN REPETITIVE <br />MEMBER CONDITIONS. <br />6. FOR MULTIPLE HOLES, THE AMOUNT OF UNCUT WEB BETWEEN HOLES MUST EQUAL AT LEAST TWICE THE DIAMETER (OR LONGEST SIDE) OF <br />THE LARGEST HOLE. <br />7. %2" ROUND KNOCKOUTS IN THE WEB MAY BE REMOVED BY USING A SHORT PIECE OF METAL PIPE AND HAMMER. <br />8. HOLES MAY BE POSITIONED VERTICALLY ANYWHERE IN THE WEB. THE JOIST MAY BE SET WITH THE 1Y" KNOCKOUT HOLES TURNED WITHER <br />UP OR DOWN. <br />9. THIS TABLE WAS DESIGNED TO APPLY TO THE DESIGN TO APPLY TO THE DESIGN CONDITIONS COVERED BY TABLES ELSEWHERE IN HIS <br />PUBLICATION. USE THE BC CALC SOFTWARE M CHECK OTHER HOLE SIZES OR HOLES UNDER OTHER DESIGN CONDITIONS. IT MAY BE <br />POSSIBLE TO EXCEED THE LIMITATIONS OF THIS TABLE BY ANALYZING A SPECIFIC APPLICATION WITH THE BC CALC SOFTWARE. <br />HOLE CUTTING CHART <br />N.T.S. <br />up to 3" to avoid <br />vertical plumbing <br />3" max <br />JOISTS OFFSET <br />kit &) <br />MUGT15 TYP. <br />5/8"e <br />THRU <br />BOLT <br />LISP ' <br />MUGT15 TYP. <br />GIRDER TRUSS <br />r- 2X TOP PLATE <br />2 X B.U.0 <br />TYPICAL USP MUGT15 TO <br />BUILT-UP COLUMN DETAIL <br />TYPICAL HUS INSTALLATION <br />MIN. EMBEDMENT <br />SCHEDULE FOR <br />AND QUANTITY <br />)F FASTENERS <br />TYPICAL HTA 20-18 / HTA 20 <br />INSTALLATION <br />WIT <br />lots]: W011 <br />�II�II�II�IIi�11�1iA1�� �: ' <br />Backer block (12" wide min.) I — — <br />Nail with 10-10d nails. - — <br />Install tight to top flange. SLEEVE THRU STEM <br />e, <br />SEE PLAN FOR °• • <br />Joist hanger FOUNDATION INFO < a <br />STEM FOUNDATION <br />Filler block. GRADE REINF. SEE PLAN <br />Nail with <br />10-10d nails. <br />Backer block required where top a n �E- <br />mount hanger load exceeds 250 lbs. <br />Install tight to top flange. <br />1/4%2" gap — <br />Backer Block <br />'Top Mount' "Face Mount" <br />Backer block shall be tight Backer block shall be tight <br />to bottom of top flange with to top of bottom flange with <br />1/4"-2" gap at top of bottom 1/4"-2" gap at bottom of top <br />flange. flange, <br />eb stiffner as <br />Web stiffeners are not required when top required if hanger <br />flange is laterally supported by joist hanger, doesn't meet <br />height <br />requirements <br />0.6 X Joist <br />" depth <br />I -JOISTS BUCKETS <br />N.T.S. <br />rv%, t,nrnx 4 rvt, <br />SLEEVE THRU FOOTING <br />MONO FOUNDATION <br />TYP. FND. PENETRATIONS <br />SCALE: N.T.S. <br />GRADE <br />HTA 20-18 / HTA 20 <br />INSTALLATION @ MID SPAN <br />LOCATION OF NOTE: <br />UPLIFT VALUE <br />SECOND RT11 IS BASED ON <br />S.P.F. <br />USP RT16 USING <br />16-8d A 1/2" NAILS <br />' UPLIFT =1030# <br />TYPICAL RT16 INSTALLATION <br />TYPICAL MTW INSTALLATION <br />TOP (2) #5's x 4'-0" <br />CENETERED @ PIPE <br />PENETRATION <br />PLUMBING LINE <br />PVC OR SCH40 SLEEVE <br />e <br />i- SEE FND. PLN. <br />SIZE & REINF. <br />12" BELOW PIPE VERTICAL THRU FND. <br />GRADE <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />q e d <br />a e .'A <br />\ • 0. •. • <br />� e <br />SEE FND. PLN. <br />SIZE & REINF. <br />PIPE PERPENDICULAR TO FND. <br />TOP (2) #5's x 4'-0" PVC OR SCH40 SLEEVE <br />CENETERED @ PIPE <br />PENETRATION PLUMBING LINE <br />Q d <br />d aa. a ev G <br />a <br />d <br />e v e . a —'� II— <br />o _ <br />a jd <br />SEE FND. PLN. <br />SIZE & REINF. <br />on <br />Ch T <br />Z o <br />— o <br />Z <br />n_ <br />z <br />U) <br />V) (D <br />a) a, <br />4-J w <br />O w <br />� <br />N <br />�� 1-` <br />r_ <br />In � <br />U <br />w <br />i— E <br />—R <br />N <br />0)cc Cl <br />f0 :S M <br />O`o,, <br />aj <br />U_� <br />Ly N <br />R CM <br />ac <br />o <br />1 <br />N.C•B -D-C <br />�ii <br />01 <br />N N���'iJ � <br />m <br />•� � <br />i <br />co pLLII�� <br />Gr <br />LL <br />Iwo < <br />=,^ <br />SSIfl <br />�o <br />fQIi81a��'�, <br />0 <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />ON <br />Z <br />0 <br />> (,r) M O <br />M <br />aU�I' <br />Ln <br />ai 0 Ln <br />Q - U_ <br />CL <br />i— . M <br />oC V Q 00 <br />a � <br />Z 3 E <br />W �to <br />d- <br />0 <br />�o <br />z g.. <br />�a <br />I- <br />¢°d1 <br />�o �� <br />wWa <br />��zZ <br />o� w <br />C <br />��o <br />m N <br />�o <br />Z Z <br />A\ <br />LU <br />,, o <br />U <br />Z <br />Z <br />Ln <br />Q <br />c <br />G <br />Ov <br />� <br />.1wwwwwwwwq <br />ZZo <br />= <br />H <br />9- <br />0 9. <br />OR OZ <br />N <br />� <br />ZaoJ <br />W 0 J <br />Q z <br />r..L <br />a�wcc <br />Z <br />w <br />w��0 <br />a�o <br />LLI <br />o <br />�¢F <br />00 <br />Q <br />Z <br />z <br />Q�z <br />�Z <br />m <br />o <br />z <br />g <br />LU <br />a <br />L0 <br />2 <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: FGUZMAN <br />VERSION N0. <br />2.0 <br />SHEET NO. <br />SN 1 <br />