Laserfiche WebLink
3 <br />v <br />a <br />N <br />0 <br />rn <br />LO <br />LO <br />.z <br />x <br />co <br />N <br />O <br />LO <br />I <br />rn <br />E <br />v <br />x <br />rn <br />C <br />a <br />N <br />E <br />c <br />d <br />EE <br />b <br />i <br />ri <br />i <br />L� <br />rn <br />0 <br />t2 <br />s <br />rn <br />0 <br />CD <br />29 <br />12 <br />5� <br />HEEL <br />12 <br />zz:::::�5 <br />T.O.M.--�`------- <br />HDR HGT. <br />TEXTURED <br />C CEMENTICIOUS <br />' FINISH ON C.M.U. <br />60 co <br />(TYP.) <br />F.FL. <br />— ------------------------------- <br />9 <br />12 <br />:7�5 <br />INININININININ <br />ININININININININII <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />FRONT ELEVATION - Al <br />SCALE: 1/4"=1'-0" <br />14'-0" RIDGE VENT <br />12 <br />5� <br />12 <br />zz::::�15 <br />15'-0" RIDGE VENT <br />3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />— — — — — — — — — T.O.M. <br />---------------------------------------------------------------- HDR HGT. <br />------------------------ <br />6" FASCIA <br />10 <br />TEXTURED o <br />CEMENTICIOUS CD °D <br />FINISH ON C.M.U. co <br />(TYP.) <br />F.FL. <br />LEFT ELEVATION - Al <br />1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />"CALCULATIONS BASED ON THE FOLL0IMNG VALUES, SEE ROOF PLAN - <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SO. FT. <br />a <br />0 � <br />0 <br />0 <br />0 <br />z_ <br />z <br />z g <br />to z <br />as N <br />M. <br />.0 <br />LLr <br />N c <br />�N <br />,U„ <br />'® 120 <br />O <br />S <br />U <br />0 <br />so <br />N �O <br />U) <br />r7 U <br />ED XX a <br />us a.-$ 3 <br />Z <br />t •. S0rr <br />s CO •` <br />R0FESS�Q����k <br />�r�t'�(ttttttti4t�� <br />To the best of the Engineers knowiedge, infonnallon and belief, <br />the structural plans and specifications contained within these <br />drawings oompty with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineers signature and seal is only for <br />the sbuctural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />C:,w <br />CM <br />2 <br />Q <br />� <br />o o <br />Z8 <br />so <br />E v <br />_ <br />�' <br />o� <br />oa <br />W <br />Sz <br />z <br />O E <br />C r0 <br />dp <br />o <br /><o <br />wz <br />a <br />m0 <br />zN <br />,ID <br />to <br />C <br />- <br />� J <br />H x <br />� <br />F o <br />zLL <br />zZ <br />,e <br />77���.. Y� <br />W� <br />yE <br />�� <br />(� <br />g <br />CC) <br />il< <br />o <br />3 <br />C O <br />0 <br />^L' <br />W`/ <br />� <br />N <br />J <br />0 <br />^C^'' m <br />W � <br />T <br />CF) <br />Z .- <br />T <br />Ln <br />O) <br />T T N <br />y CO <br />r <br />hi <br />E <br />M N <br />N y <br />o <br />Z <br />Z <br />a <br />E 0 <br />c <br />v Q o <br />_° <br />JOB <br />NO: 19-5904 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.1 <br />