My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3192 Moulden Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3192 Moulden Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 10:09:49 PM
Creation date
2/19/2025 8:57:38 AM
Metadata
Fields
Template:
Building Plans
Street #
3192
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19066
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VENTED SOFFIT <br />46 SQ. FT. <br />ZONE-1 <br />ATTIC SPACE <br />2276 SQ. FT. <br />d <br />VENTED SOFFIT <br />46 SQ. FT. <br />125 SLOPE <br />F.10 <br />VENTED SOFFIT <br />61 SQ. FT. —7 <br />a <br />..0 <br />4'-0' ROOF V • T <br />16'-0' RIDGE VENT <br />RIDGE <br />yA <br />4'-0' ROOF VEMT ; <br />W I 11 I <br />O I l l I <br />T I I 1 1 <br />II 11 <br />Al <br />N <br />T <br />in <br />5:12 <br />5:12 SLOPe <br />�•' <br />,Qy O <br />04 �Q 1 . <br />tiiL0 �•: <br />RIDGE 5:12 SLOP Vx, <br />I'-O' RIDGE VENT �•'; ,' <br />'Sio r. <br />............................................................. <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION REQUIRED <br />UPPER VENTILATION PROVIDED <br />1/150 Rule <br />1/300 Rule <br />Ridge <br />Off -Ridge <br />(No Upper Ventilators <br />(Must Provide Upper Ventilators) <br />Vent Amt <br />Amt. <br />Req.) <br />(Ft.) <br />Total <br />Ventilation <br />ATTIC <br />Provided <br />SPACE <br />SQ. FT. <br />Total SQ. <br />SQ. FT. <br />SQ. IN. of <br />by Upper <br />pp <br />SQ. IN. of <br />ventilation of vented <br />IN. of <br />of <br />vented <br />ventilation to <br />be provided <br />. <br />SQIN. of <br />SQ, IN. of <br />Ventilators <br />El S <br />(See ev <br />( ) <br />required soffit <br />ventilation <br />soffit <br />by upper <br />Ventilation <br />Ventilation <br />needed <br />required <br />needed <br />ventilators <br />Main <br />20.00000 <br />2.000000 <br />Floor <br />2276 <br />2185 <br />312 <br />1092 <br />78 <br />546 <br />0 <br />576.0 <br />300.0 <br />276.0 <br />(Zone 1) <br />**NOTE** <br />GENERAL CONTRACTOR MUST ENSURE THAT PROPER VENTILATION IS PROVIDED AT EAVES/SOFFITS AS <br />REQUIRED BY FBC 5th ED. RESIDENTIAL. <br />VENTED SOFFIT LEGEND <br />IF SOFFIT IS LABELED AS "NON -VENTING" FIRE PROTECTION WILL BE INSTALLED <br />AS REQUIRED BY SECTION R302 OF THE FBC 5th EDITION (2014) RESIDENTIAL. IF <br />LABELED AS "VENTED", NO FIRE PROTECTION WILL BE REQUIRED. <br />VENTED SOFFIT <br />VENTED SOFFIT <br />56 SQ. FT. <br />ROOF PLAN <br />SCALE: %4'=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.6 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.6.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.6.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.6.3 Water-Resisitive Barriers. <br />Water-resisitive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paperbacked <br />stucco lath) over an approved synthetic house wrap. <br />R703.8 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry contructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 5th Edition <br />(2014) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or comics vents. <br />-CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SQ. IN. OF NET FREE AREA / SQ. FT. <br />• O'HAGIN WEATHERMASTER (Shingle Roof) - 72 SO. IN. OF NET FREE AREA/ FT. <br />** (Sq. Ft Soffit Needed) x 7 = (Sq. in. Needed) / 72 = Amount of O'Hagin vents Needed <br />• LOMANCO DECK -AIR (Shingle Roof) - 9 SQ. IN. OF NET FREE AREA / FT. <br />*'Formula: (Sq. Ft. Soffit Needed) x 7 = (Sq. In. Needed) 19 = Linear Ft of Deck -Air Needed) <br />• O'HAGIN (Tile Roof) - 86.25 SO. IN. OF NET FREE AREA / VENT <br />**Formula: (Sq. Ft Soffit Needed) x 7 = (Sq. In. Needed) / 8625 = Amount of O'Hagin Vents Needed <br />0 <br />Z o <br />—0 <br />Z <br />J <br />r2 <br />v, Z <br />V7 <br />Q) C <br />w <br />U — <br />0 w <br />0 <br />V)= <br />o 0 <br />U <br />0M <br />w <br />F— <br />—$ <br />Rig <br />M <br />C cc co <br />E 72 - <br />Ooa <br />(D <br />�� i,ii II U W <br />1i <br />u <br />LLCD <br />I _ <br />0 Co iz <br />Ill111 <br />L Y <br />Qrn <br />O q <br />u� �r <br />0. <br />rnQo <br />CZ01 <br />N-C-B-D C� <br />d <br />� <br />SE ° °° <br />°o y} <br />�. C� •,� <br />co <br />cc <br />N <br />x `.� r-. V <br />S a <br />CN <br />CO <br />pz¢ry,J„ � <br />c@��t e-f <br />� z <br />- Id <br />w <br />°• W , ` '� <br />w <br />CL <br />rvv \ <br />co m <br />°�� <br />In <br />N O <br />O <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />O <br />O <br />Z N <br />O <br />.2 N <br />r>-r V) M O <br />M <br />Q -p Lf1 <br />i2 to L d- <br />Q 0 LPG <br />fl- <br />I- , M <br />00 QUa''' <br />Z � � <br />J <br />WC) <br />C:) <br />MJ <br />G� <br />zu, <br />¢a <br />�a <br />H <br />��� <br />�z0,o <br />W <br />Q z z <br />y <br />pC J <br />LO <br />W � <br />z0N <br />f- W <br />L <br />Z <br />y0 <br />Qz <br />: <br />z <br />g� <br />D <br />UU <br />J <br />= <br />CL <br />'o W <br />0 ' <br />LL <br />40� <br />O <br />0 <br />O <br />°d0¢ <br />a <br />a <br />rN. <br />W d <br />Z <br />Z <br />LLJ <br />Lr) <br />L.li <br />D2 <br />U o <br />6i <br />a LL <br />Ozo <br />?�z <br />Z <br />a <br />�z <br />03 <br />O <br />Q <br />_I <br />LU <br />= <br />¢ z <br />n <br />ri <br />a_ <br />V) <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: ERAND <br />VERSION No' 10 <br />SHEET NO. <br />5.0 <br />