Laserfiche WebLink
:JTMP) SEE ELEV. <br />SIMPSON SP2 w/ (12)1Od <br />NAILS AT EACH STUD <br />CRICKET AS REQUIRED <br />SINGLE 2x CONT. BASE <br />PLATE W/ (2)16d TO <br />TRUSS BELOW <br />(2) 2x6 OR (2) 2x8 <br />TOP PLATE SEE <br />PLAN <br />(2) 2x HEADER TO SIT <br />2x6 ! 2x8 WALL BEYOND <br />FLUSH TO THE OUTSIDE <br />SEE PLAN FOR HEADER <br />SEE PLAN FOR SIZE <br />CONNECTION <br />2x DEAD WOOD @ MID <br />POINT w/ (3)12d <br />TONEAILS SPACED <br />DOUBLE 2x TOP <br />EVENLY <br />PLATE <br />2x BLOCKING @ EACH END W/ 1 Od @ <br />4" O.C. FROM EACH HEADER FACE <br />TO BLOCKING <br />(2) 2x HEADER <br />PER PLAN <br />VARIES 2x BOTTOM PLATE W/ (1)10d @ 8" <br />O.C. TO EACH HEADER FACE <br />2 x 6 (MIN.) FRAME <br />WALL HEADER DETAIL ri <br />SCALE: N.T.S. S4 <br />SEE TYPICAL WALL SECTION <br />PRE-ENGINEERED WOOD <br />TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR <br />(SEE SCHEDULE) <br />DOUBLE 2x4 SPF. #2 <br />TOP PLATE <br />2x S.P.F. STUDS @ 16" O.C. <br />SINGLE 2x CONT. TOP <br />PLATE W/ (2)12d INTO <br />TRUSS ABOVE <br />2x CLOSURE WALL W/ <br />STUDS @ 16" O.C. W/ <br />(3)10d TOENAILS T&B <br />AS REQ'D <br />Zx BLOCKING @ MID <br />POINT EVERY OTHER <br />STUD W/ (3) 1Od NAILS <br />1/2" EXTERIOR GRADE SHEATHING nI- <br />U <br />FASTENED TO TRUSSES WITH 8d COMMON <br />WIRE NAILS @ 4" O/C BOUNDARIES 6" O/C <br />EDGES & 8" O/C FIELD <br />SIMPSON SP1 w/ (10)10d <br />ELL <br />NAILS AT EACH STUD <br />N 2x P.T. PLATE <br />5/8" x 10" "J" BOLT @ 24" O/C MAX <br />W/8"EMBEDMENT <br />C" 8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />N <br />AND FILLED SOLID W/GROUT <br />5 1 #5 VERT. IN CONC. FILLED CELL W! <br />:j <br />m STD. 90A HOOK IN K.O. BLOCK <br />N KNEE WALL ABOVE MASONRY WALL DETAIL <br />BLOCKING (TYP.) <br />\—ROOF TRUSS <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />MOISTURE BARRIER <br />SCALE: N.T.S. <br />iu <br />"x <br />I <br />~- I co <br />MOUNTING BASE NOT SHOWN <br />y <br />FOR CLARITY SEE DETAIL <br />c <br />K/S4 <br />02 <br />SEAT FOR BLOCK IS POURED, <br />IN PLACE CONCRETE <br />J <br />GARAGE FLOOR SLAB <br />TROWEL FINISH SEE <br />sn <br />GENERAL NOTES <br />o <br />SLOPE FORWARD <br />FOR DRAINAGE <br />m_ <br />oZ SEE PLAN FOR FOOTING <br />DIMENSIONS <br />GARAGE ENTRY FINISHED MASONRY DETAIL <br />SCALE: N.T.S. <br />W <br />1/2" MINIMUM CEMENT FINISH <br />STANDARD 3"DIA. TEE <br />THREADED 3" DIA. EXTENSION <br />SCREW OFF CAP (3" DIA.)--� <br />FOR CLEAN -OUT <br />MIN. EXTENSION FROM <br />EXTERIOR FACE OF BLOCK <br />WALL IS 1 1/2" MAXIMUM <br />EXTENSION FROM EXTERIOR <br />FACE OF BLOCK WALL IS 21/4" <br />VENT OR 2ND FLOOR <br />TYPICAL C.M.U. WALL <br />3/4" FURRING STRIPS <br />1/2" GYPSUM BOARD <br />W/ DRYWALL SCREWS <br />@ 8" O.C. OR 4d <br />DRYWALL NAILS <br />DRAIN <br />WALL CLEAN -OUT q <br />SCALE: N.T.S. S4 <br />REFER TO WINDOW PRODUCT APPROVAL <br />SHEETS FOR INSTALLATION INFORMATION BY <br />MANUFACTURER. <br />TYPICAL SECTION THRU WINDOW <br />KNOCK -OUT NOTCH LINTEL WHERE REQUIRED <br />BLOCK W/ (1) #5 FOR CONCRETE PLACEMENT <br />. • • <br />IBM'— <br />._ <br />' <br />1'I <br />MEN <br />�IIlI <br />IIII� <br />- - - Milli-IIIIT� <br />NOTES: <br />10 FILL LINTEL AND ALL CELLS ABOVE LINTEL. <br />NOTE: FOR BEAM DEPTH 22", PROVIDE A 4" x 4" INSPECTION <br />PORT <br />@ EACH VERTICAL REBAR & DIRECTLY ABOVE THE LINTEL. <br />O VERIFY THAT ALL REINFORCEMENT HAS BEEN PLACED <br />PROPERLY. <br />(DSEE FLOOR PLAN FOR ADDITIONAL INFORMATION. <br />® OPENINGS LESS THAN OR EQUAL TO V-0" IN WIDTH DO NOT <br />REQUIRE ADDITIONAL STEEL REINFORCEMENT UNLESS NOTED ON <br />FLOOR PLAN. <br />TYPICAL FILLED LINTEL ASSEMBLY <br />SCALE: N.T.S. <br />WIDTH OF OPENING VARIES 4" FORM CONCRETE INSET TO <br />1/2"X91/2" PLYWOOD CREATE A SOLID BASE FOR <br />MATERIAL SCRAP BLOCK WALL ABOVE. <br />MOUNTING BASE SHOWN <br />IN POSITION <br />2x6 MOUNTING BASE <br />J <br />" <br />T �J <br />o <br />FORM CREATES CONCRETE RECESS TO <br />2x4 (NOM.) RECEIVE GARAGE DOOR AND TO ALLOW <br />FOR WATER SHED. <br />KEEP STIFFENER BACK FROM SIDES ENOUGH <br />TO ALLOW SPACE FOR FLAT MASONS TOOLS <br />(THIS IS A RECOMENDATION FOR CONSTRUCTION OF THIS FORM. ANY <br />MATERIAL OR CONSTRUCTION METHOD MAY BE USED PROVIDED END <br />PRODUCT MEETS THE SHAPE AND DIMENSIONS OF THIS DRAWING.) <br />GARAGE ENTRY FORM DETAIL <br />�8x8x16 C.M.U. GARAGE DOOR <br />GARAGE DOOR ROLLER _ <br />CONNECTION ASSEMBLY <br />GARAGE FLOOR <br />TRAVEL DIRECTION OF <br />GARAGE DOOR <br />MOUNTING BASE DETAIL <br />SCALE: N.T.S. <br />-TRACK MOUNTING BRACKET <br />\GARAGE DOOR TRACK <br />SCALE: N.T.S. d <br />d E c c ^ a n c <br />POURED CONCRETE BASE FOR BOTTOM OF MOUNTING B <br />BLOCK WALL. RECESSED SPACE TO BE 2" ABOVE FINISHED <br />FOR GARAGE DOOR AND WATER GARAGE FLOOR. <br />SHED FORWARD THIS DRAWING. <br />PARTIAL INTERIOR ELEVATION <br />SCALE: N.T.S. <br />7 5/8" 8" 7 5/8" 8" 7 5/8" 8" <br />INTERIOR <br />WALL <br />GL <br />EXTERIOR J <br />WALL <br />SOLID AREAS ARE <br />STEEL AND GROUT <br />FULL 8x8x16 BLOCK <br />DOOR OPENING <br />1 ST COARSE 2ND COARSE 3RD COARSE <br />MASON TO LAY BLOCK AS SHOWN ABOVE. EVERY COARSE MUST BE BONDED TO THE <br />COARSE BELOW. EVERY THIRD (3RD) COARSE THE 11" DOORJAMB WALL IS TO BE <br />WOVEN INTO THE MAIN FRONT TO REAR WALL AS SHOWN. <br />MASONRY LAYOUT D <br />SCALE: N.T.S. SL� <br />VERTICAL JAM <br />5/8"DIA. x 8" J-BOLTS AT 6-3/4", 41-3/4", 71", AND 96-3/8" ABOVE GARAGE <br />FLOOR. ALL J-BOLTS WILL BE IN FILLED CELLS (2,000 PSI MIN. <br />CONCRETE). ANCHORS MAY BE COUNTERSUNK (BUT NOT REQUIRED) <br />RUSS BOTTOM CHORD OR 2x4 <br />TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO <br />FBLOCKINGW/ 2-16d TOE NAILS <br />NOT TRANSFER LOAD. <br />EACH END <br />a <br />° d <br />WALL <br />° <br />° <br />DOOR STOP <br />w <br />c� <br />a <br />d <br />MOLDING <br />a <br />d <br />2x TOP PLATE <br />T <br />GARAGE <br />2-16d NAILS @ 24" O.C. OR <br />DOOR <br />EQUAL TO TRUSS BOTTOM <br />CHORD OR BLOCKING <br />2 x 6 P.T. <br />2x STUD @ 24" <br />O.C. MAX. <br />2x P T PLATE <br />PROVIDE P.A.F. NAILS OR <br />EQUAL @ 12" O.C. <br />SEE TYPICAL WALL SECTION <br />12 <br />(TYP) SEE ELEV. <br />PRE-ENGINEERED WOOD TRUSSES @ 24" O/C <br />UPLIFT CONNECTOR (SEE SCHEDULE) <br />DOUBLE 2"x4" S.P.F. TOP PLATE <br />7/8" STUCCO FINISH PER ASTM C. 926 <br />APPLY 3 LAYERS W/ TOTAL THICKNESS <br />7/8" OVER METAL LATH. FIRST 2 <br />LAYERS 3/8" THICK EACH. 3RD LAYER <br />1/8" THICK. <br />/—CRICKET AS REQUIRED <br />SIMPSON SP2 w/ (12)10d <br />NAILS AT EACH STUD <br />1/2" EXTERIOR GRADE SHEATHING <br />FASTENED TO TRUSSES WITH 8d <br />COMMON WIRE NAILS @ 4" O/C <br />BOUNDARIES 6" O/C EDGES & 8" <br />BLOCKING (" <br />O/C FIELD <br />2X4 PT STUDS @ 16" O.C. <br />(2) 2X4 PT STUDS UNDER HIP <br />CARRIER/GIRDER TRUSS <br />- - - <br />SIMPSON HETA20 w/ (8)1Odxl 1/2" <br />NAILS AT EA. TRUSS VERTICAL WEB <br />(24" O.C. MAX) w/ MIN. 4" EMBEDMENT <br />LMAIN <br />IN KO BLOCK AT EA. STUD <br />SPAN <br />ROOF TRUSS <br />MOISTURE BARRIER <br />UPLIFT CONNECTOR <br />8"X8"X16" K.O. BLOCK W/ 1 #5 CONT. <br />(SEE SCHEDULE) <br />AND FILLED W/ GROUT <br />1 #5 VERT. IN CONC. FILLED CELL--- <br />W/ STD. 900 HOOK IN K.O. BLOCK <br />ALT. KNEEWALL ABOVE MASONRY WALL DETAIL E <br />PIPE OR DUCT w! PENETRATION THRU TOP PLATE w/ MORE <br />THAN 50% OF TOP PLATE WIDTH INSTALL SIMPSON <br />PSPN516Z w/ (12)16d NAILS <br />TOP 2 ROWS 10d @ 3" O.C. (14 <br />SPLICE NAILS TOTAL) EA. SIDE OF <br />4,9. SPLICE <br />HICE STAGGERED <br />Od @ 8" O/C <br />STAGGERED FROM BOT. ATTACH ALL J <br />SEE A/S3 FOR DOOR TRACK EXTERIOR STUDS W/ <br />REINF. INFO. PLATE TO CONCRETE W/MOUNTING ANGLE (4 16d TOENAILS <br />TO 7bP PLATE <br />NOTE: REFER TO GARAGE DOOR PRODUCT APPROVAL SHEETS NOTE: <br />FOR DOOR INSTALLATION INFORMATION PER MANUFACTURER. PLATE LENGTHS MUST BE BOTTOM SPLIC <br />AT LEAST 4'-0" LONG. TYPICAL OVER STUD <br />TYPICAL INTERIOR NON - <br />BEARING WOOD FRAME WALL TYPICAL GARAGE DOOR BUCK K TOP PLATE SPLICE DETAIL M <br />SCALE: N.T.S. S4 SCALE: N.T.S. S4 SCALE: N.T.S. S4 <br />F= 2240 LBS <br />SIMPSON SIMPSON SIMPSON C <br />HEADER SUPPORT <br />NO. OF JACKS & STUDS <br />REQ. AT OPENINGS <br />OPENING <br />2" x 4" WALL <br />2" x 6" WALL <br />STRAPS <br />JACKS <br />STUDS <br />JACKS <br />STUDS <br />SIZE <br />EA END <br />EA END <br />EA END <br />EA END <br />SIMPSON <br />1'-4' <br />(1) <br />(2) <br />(1) <br />(2) <br />(1)LSTA30 <br />4' - 9' <br />(2) <br />(3) <br />(2) <br />(2) <br />(1) LSTA30 <br />9' -16' <br />(3) <br />(4) <br />(2) <br />(4) <br />(2) LSTA30 <br />N, <br />SCALE: N.T.S. S4• <br />2"x BUILT-UP COLUMN, SOLID MEMBER OR <br />P.L. 1.8E Fb=2400 PSI (AS PER PLANS) <br />° o C • HTT4 w/ (18)1 Od NAILS (3610# SPF) <br />"o • HTT5 w/ (26)10d NAILS (4670# SPF) <br />" o 9 DTT2Z w/ (8)1/4" x 1 1/2"SDS (1835#SPF) <br />"o a • HDU2-SDS2.5 w/ (6)1/4" x 21/2" SDS (2215# SPF) <br />" " • HDU4-SDS2.5 w/ (10)1/4" x 21/2" SDS (3285# SPF) <br />_ • HDU5-SDS2.5 w/ (14)1/4" x 21/2" SDS (4065# SPF) <br />- • HDU8-SDS2.5 w/ (20)1/4" x 21/2" SDS (5665# SPF) <br />• HDU11-SDS2.5 w/ (30)1/4" x 21/2" SDS (6865# SPF) <br />• 5/8" DIA. x 12" EPDXIED A.T.R. MIN. 8" <br />EMBEDMENT w/ WASHER & NUT <br />0 • FOR DTT2Z USE 1/2" DIA. x 12" EPDXIED <br />A.T.R. MIN. 8" EMBEDMENT w/ WASHER & <br />NUT <br />• FOR HDU8 USE 7/8" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />• FOR HDU11 USE 1" DIA. x 12" EPDXIED A.T.R. <br />MIN. 8" EMBEDMENT w/ WASHER & NUT <br />HTT / HDU TENSION TIE rN <br />SCALE: NTS S4 <br />SP4 SP2 SIMPSON SP4 3P2 SIMPSON SP4 <br />2X TOP PLATE <br />2X STUDS @ 24" O.C. OVERLAPPING <br />4 r <br />If I <br />/8"xl0" "J" BOLT NAILED <br />@ 24" O.C. MAX. INTO <br />MIN. (2) PER TRANSOM <br />BOTTOM PLATE TRANSOM FRAMING FRAMING <br />2XPT <br />SEE SECTION AA/S1 <br />FLAT STRAPS PER CHART ABOVE TO BE BENT SECTION <br />PLATE AND BB/S1 FOR <br />OVER TOP PLATE ** HOLD DOWN CONNECTIONS <br />NOT REQUIRED @ BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />SEE FLOOR PLAN NOTES FOR <br />REQUIRED CONNECTION <br />2-ROWS 12d NAILS STAGGERED <br />@ 12" O/C EACH FACE OR <br />3-ROWS 12d NAILS STAGGERED <br />@ 12" O/C FOR 2"x10" OR <br />2x CRIPPLES @ <br />GREATER HEADER <br />16" O.C. W/ (2)12d <br />TOENAILS T/B <br />SIMPSON SP4 w! (6) <br />(2) 2x HEADER SEE PLAN <br />1 Od x 1 1/2" AT EAri <br />STUD (USE SP6 FOR <br />• INTERIOR HEADER: <br />S4 <br />2x6 WALL, USE SP8 <br />(1) 2x SILL PLATE W/ (2) <br />FOR 2x8 WALL) <br />12d TOENAILS <br />1Od NAILS @ 8" <br />BOX HEADER • EXTERIOR HEADERS: <br />ONLY <br />O/C TYP. <br />(1) 2x SILL PLATE W/ (2) <br />12d TOENAILS <br />DOUBLE 2x <br />• OPENING LARGER THAN 4 FT: <br />CRIPPLE STUD <br />(2) 2x SILL PLATE w/ SIMPSON <br />TYPICAL (U.N.O.) <br />LS30 w/ (6)1Old x 1 1/2" EACH <br />SIDE <br />2x STUDS TYP. <br />00 SIMPSON HTT4 TYP. <br />Op OR U.N.O. SEE N/S4 <br />FN��G <br />** HOLD DOWN <br />CONNECTIONS <br />NOT REQUIRED @ <br />P.T. BOT. PLATE BEARING WALLS NOTED <br />WITHOUT UPLIFT <br />WALL HEADER DETAIL rQ_ <br />SCALE: N.T.S. S4 <br />ADDITIONAL DETAILS <br />SP4 <br />/-RECESS <br />/ LINTEL <br />TRANSOM FRAMING <br />SEE SECTION AA/S1 AND <br />BB/S1 FOR ADDITIONAL <br />DETAILS <br />LINTEL <br />d <br />dO d <br />c <br />SIMPSON SIMPSON <br />SP4 SP2 <br />NAILED INTO <br />TRANSOM <br />FRAMING <br />SIMPSON <br />Sp1 SIMPSON <br />SIMPSON SP4 <br />/ SP4 <br />SIMPSON <br />SP1 <br />SIMPSON SIMPSC <br />SP4 SP4 <br />—10d NAILS @ 6" <br />STAGGERED <br />J-BOLTS @ 24" O.C. <br />MAX <br />—2X P.T. PLATE <br />ROOF TRUSS ABOVE <br />r' 2X BLOCKING <br />o I I <br />d 2X8 P.T. BOTTOM P TE G' <br />5/8"x10" "J" BOLT @ 24" O.C. MAX. B <br />C (MIN. (2) PER BOTTOM PLATE) <br />SIMPSON C <br />SP4 <br />1 d A " <br />2X8 P.T. BOTTOM <br />PLATE <br />UU <br />5/8"xl0" "J" BOLTS @ 24" O.C. MAX. <br />(MIN. (2) PER BOTTOM PLATE) <br />(2) 16d TOE NAILS <br />EA. BLOCKING <br />2X8 WALL ABOVE <br />ENTRY <br />K.O. BLOCK W/(1) <br />#5 CONT. & <br />FILLED <br />5/8"X10" J-BOLTS <br />@ 2'-0" O.C. <br />-MASONRY WALL <br />0 N ILS @ 4 10d NAILS @ 6" O.C. <br />STAGGERED A STAGGERED <br />TRANSOM FRAMING <br />o o BEYOND. <br />PLYWOOD FASTENED TO TRUSSES <br />WITH 8d COMMON WIRE NAILS @ 4" 1 PLYWOOD <br />0/C BOUNDARIES 6" 0/C EDGES o E SHEATHING <br />& 8" O/C FIELD <br />S4 <br />B <br />• SIMPSON SP4 w/ (6)10d x 1 12" <br />(USE SP6 FOR 2x6 WALL, USE PLYWOOD <br />SP8 FOR 2x8 WALL) 0 SHEATHING <br />• SIMPSON SP2 w/ (12)10d NAILS MASONRY <br />• SIMPSON SP1 w/ (10)10d NAILS WALL BELOW 5/8"X10" J-BOLTS @ 24" O.C. <br />MAX. (MIN. (2) PER BOTTOM <br />PLATE) <br />ALTERNATE: <br />5/8" DIA. ATR EPDXIED <br />MIN. 6" INTO BOND BEAM <br />@ 24" O.C. <br />FRAMING DETAILS ABOVE ENTRY rR� <br />SCALE: N.T.S. <br />Lo <br />z_o <br />z� <br />z� <br />Q <br />J <br />a <br />Z <br />W <br />Q� 0 <br />rz_ o <br />�V — <br />0 C!'_ <br />t.h <br />e <br />� U <br />oh <br />m <br />a�-, M <br />W <br />W� <br />C 1M <br />fLLC <br />� <br />Q <br />Rig <br />a; <br />A <br />1 <br />N C•B D C <br />•E <br />^N <br />MU) <br />�•' <br />O <br />LY <br />LU <br />WL �'a•• <br />a• 0`'2 <br />- <br />To the best of the Engineers' h ylef,a��p!�.j�(6 on, and <br />belief, the structural plans and s cfc& ati6hs contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />CD <br />Z fV <br />I� <br />O�CD <br />to M cO <br />M <br />Q 'M Lr) <br />a. cn •L � <br />U_ <br />Q C Ln <br />CL ^ <br />cj� a� <br />Q C Co <br />Z � <br />W <br />J <br />d- <br />W — <br />za <br />d <br />4 o <br />$Wz 99 <br />z <br />z <br />V W <br />f J <br />�1f1--8 <br />V 1E Z <br />-� <br />8 <br />I <br />0C <br />Z <br />, ^3 <br />1� <br />N <br />u <br />= <br />N <br />u) <br />Q <br />LU <br />ouj <br />� . <br />0 <br />0 J <br />� 0 <br />0aU4�3 <br />13� <br />Q <br />Z <br />N <br />W� <br />J <br />Ln <br />LV� <br />rl <br />Wa <br />Z91 <br />~g <br />co <br />O1 <br />N <br />0o <br />Z <br />ZUJI <br />g <br />� <br />0 <br />.� <br />0- <br />= <br />cn <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION N0. 5ol <br />SHEET NO. <br />S4 <br />