My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3196 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3196 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:22:46 PM
Creation date
2/19/2025 8:58:18 AM
Metadata
Fields
Template:
Building Plans
Street #
3196
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
m <br />11 <br />a <br />I— <br />E <br />S <br />(1: <br />N <br />t <br />W) <br />R <br />W, <br />ki <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />NEMA t <br />200 AMP <br />n <br />200 amp <br />150 amp <br />copper to fights & Outlets <br />copper to 20 amp ckts <br />2 copper to WH <br />3 copper to Dryer <br />or 4/0 SER Alu <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />�94ROUNDING <br />BONDING <br />WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance With the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory'. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />W.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />O <br />RECESSED LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />tOr <br />EXHAUST FAN/LIGHT COMBINATION <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />® <br />TELEVISION (OPTIONAL) <br />® 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />WWI_ <br />ELECTRIC PANEL <br />—J&A <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />69 <br />(1) PHONE LINE, (1) DATA PORT <br />�101 <br />�iAre DIN <br />66- a ieLs <br />WP <br />GFI <br />.. O] <br />WP <br />GFI <br />H.B. <br />-FAMIL- `-ROGM .., <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRED <br />01 <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />' FOYER <br />\ C.M <br />InE <br />I <br />GFI AkGFI <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />\ PENDANT AS <br />\PER SPECS / <br />DIN INOOM <br />I --FI I <br />-------- J <br />REF. <br />--- — OPT.— <br />e .H. X-I @ 44" <br />A.F.F. <br />or------------ <br />I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />� I <br />GFI @ 44" GFI FOR <br />A.F.F. GAR. DOOR I <br />GFI I <br />� � I <br />I <br />� I <br />I <br />I <br />I <br />I <br />VERIFY LOCATION IRRIGATION <br />L-_---------- <br />ELECTRICAL PANEL _GFI @ 44" A.F.F. <br />VERIFY METER H.B. <br />LOCATION WITH <br />BUILDER <br />WP <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: Y4'=1'-0" <br />U <br />zo <br />z <br />Q <br />room <br />a <br />z <br />w <br />.0 — <br />0 w <br />CD <br />LU <br />— $ <br />® ►-- E <br />= y <br />C0 <br />c pt0 <br />.g N <br />0 S o <br />LL7.00 <br />GO <br />Q <br />ono <br />Al I <br />B Do <br />It <br />-- <br />00 <br />N <br />rn <br />N <br />d <br />tAZ2 R <br />�z <br />Lt- <br />W ,.€LL o <br />inz <br />LU <br />a <br />J=,�AZ5 <br />m <br />LLW <br />m m <br />a <br />°do <br />❑❑ <br />To the best of the Engineer's knowledge, Information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code - Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z N <br />0 <br />� O <br />Z <br />1 M O <br />fa Ln <br />0- <br />N OIn <br />Q aL <br />Z <br />Cn <br />OC CL O <br />E ... <br />W <br />Z <br />Wo <br />O <br />J <br />%0 <br />d' <br />Z <br />W <br />Z08 a <br />U <br />z <br />z <br />J <br />�w <br />O <br />U <br />IF— <br />Z <br />W <br />Ce <br />N <br />W <br />J <br />41 <br />� <br />LU <br />�_ <br />� <br />� <br />p <br />W <br />U <br />N <br />O <br />F <br />Z <br />bob <br />Q`�`� <br />^ <br />W Q <br />Z <br />rl Ln <br />CY tQ <br />�a�� <br />J <br />--1 <br />I W <br />Q <br />Z <br />W <br />Z <br />tj <br />� 0 <br />NZ <br />cci <br />N <br />m <br />O <br />oo <br />g <br />= <br />9 <br />rn <br />.-I <br />a <br />to <br />F <br />SCALE : AS NOTED <br />DATE: 3/30/2018 <br />TECH: MJAMES <br />VERSION N0. 5ol <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.