My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3200 Mouldren Hollow Dr
Zephyrhills
>
Building Department
>
Building Plans
>
3200 Mouldren Hollow Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 11:43:53 PM
Creation date
2/19/2025 8:58:36 AM
Metadata
Fields
Template:
Building Plans
Street #
3200
Location
Moulden Hollow Dr
Contractor
Lennar Homes
Building Plans - Permit #
19246
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 <br />1 <br />I <br />I <br />1 <br />1 <br />I <br />I <br />1 <br />I <br />I <br />I <br />I <br />i <br />I <br />I <br />1 <br />I <br />I <br />1 <br />I <br />i <br />I <br />I <br />1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />1 <br />-----------------' <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. <br />INTERSY' <br />BON <br />TERMINATIOF <br />NEC 08, 250.94 J <br />200AINDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2011 NEC. <br />opper to lights & outlets <br />upper to 20 amp ckts <br />copperto WH <br />copperto Dryer <br />2 Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2011, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2011 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2011 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />FW.P. <br />WEATHERPROOF DUPLEX OUTLET <br />G.F.I. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />24 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />FLOURESCENT LIGHT FIXTURE <br />RECEPT. <br />FOR ALARM' <br />SYSTEM <br />VERIFY METER <br />LOCATION WITH <br />O EXHAUSTFAN I _ — _ —C'I I BEDROOM ' <br />PA •I.0 CAFE /�=-=I==-t--=- �l <br />;R.Q� EXHAUST FAN/LIGHT COMBINATION ' B E D Rr00 M 3 <br />®D ELECTRIC DOOR OPERATOR (OPTIONAL) \ L D.W.0 GFI <br />CH CHIMES OPTIONAL / 1 INK I DIS _i_____ j OUCH -IN FOR <br />I OPT. CLG. FAN/ <br />O PUSHBUTTON SWITCH (OPTIONAL) PENDANT AS \ I i LIGHT PRE -WIRED Ny <br />/ 1 G <br />PER SPECS �. 1� ROUGH -IN FOR <br />SD SMOKE DETECTOR \ <br />OPT. CLG. FAN/ <br />CM SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) / 10 IT I - LIGHT PRE -WIRE <br />I <br />TELEPHONE (OPTIONAL) AC PAD / 3 GFI GFI <br />_ _ <br />• ���II <br />© TELEVISION (OPTIONAL) <br />® 2 (2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. qp [3' DEDICATED RECEPTACLE <br />WP H.B. FOR MICROWAVE RANGE <br />O THERMOSTAT G IDISC. HOOD PER SPECS <br />�N ELECTRIC METER <br />_a ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />�7 <br />ROUGH -IN FOR OPT. CEILING FAN <br />v J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G J <br />OPT. CEILING FAN <br />(1) PHONE LINE, (1) DATA PORT <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Z M <br />CD <br />_ <br />Z CO <br />Z <br />Q <br />a. <br />f � Z <br />Z <br />n�n ' <br />W e/S <br />4--J w <br />W <br />O <br />F- <br />0 <br />CIO <br />�V)04 <br />o0 p <br />' V ist <br />N co <br />0)to <br />L.0 E <br />F_ <br />—3 <br />M <br />N O N <br />Ooo <br />N <br />�lJ_00 <br />I O <br />y <br />(5, Y t <br />p O <br /><Crn <br />In It <br />rnQo <br />A I <br />~ _ <br />_ <br />N <br />N <br />m <br />N <br />a�D � <br />o S rn �p <br />� <br />00 <br />0 " <br />Z o <br />�Z W0000 <br />rMmZ <br />0 O <br />LJ Z <br />/yam I. lL <br />'--I <br />L.L <br />ii J) N - <br />W <br />W to <> <br />�0-� <br />Cc 9;5 <br />H <br />C O <br />CCC <br />mm <br />Z yME��R <br />LLtaE^o <br />8 <br />� <br />Jo <br />Wa0):9 <br />N a co 0 <br />of <br />❑ ❑ <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the Florida Building <br />Code 5th Edition (2014) Residential. Engineer's signature <br />and seal is only for the structural engineering portions of <br />the drawing pages bearing Engineer's signature and seal. <br />I< <br />O <br />O <br />Z (V <br />O <br />I>—I-i (n M O <br />M <br />Q LA <br />N In <br />LLro <br />a <br />cl U fu '-.q <br />Z E <br />fB <br />W O <br />W J� <br />oZ <br />o <br />Ln <br />W� <br />Z <br />¢Q <br />z <br />Q <br />Wacl: <br />r� <br />J <br />0SW� <br />CL <br />�o�Z <br />Q <br />U <br />>aO�n <br />O�wo <br />FLo <br />"Z <br />� <br />Z Z <br />CZ,���// <br />�— <br />w <br />a <br />I..L. <br />W <br />M <br />LU <br />�QQ <br />Z <br />_0 <br />U <br />= <br />(o <br />O <br />¢ <br />U� <br />_ <br />O <br />__j <br />LL_ <br />>� <br />F0a <br />Q <br />i U� <br />r <br />u W cca <br />Z a c a <br />o¢o¢ <br />Z w Z J <br />Lu <br />Q <br />Z <br />^ <br />�0go <br />Z <br />W <br />,--I <br />I- fi <br />LLj <br />a <br />� Q o D <br />J <br />ri <br />LLI <br />o Z U <br />O ~ ~ <br />Q <br />Z <br />Z <br />jz <br />co <br />Z <br />t <br />Uj <br />to Z <br />2 <br />Ln <br />aZ <br />O <br />^ <br />g <br />= <br />uj <br />r•1 <br />1'� <br />CL <br />i /) <br />g <br />SCALE : AS NOTED <br />DATE : 2/24/2014 <br />TECH: MJAM ES <br />VERSION NO. 10 <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.