COMPOSITION SHINGLES <br />ROOF INSTALLED AS PER <br />MANUF. SPECIFICATIONS <br />F11 <br />1" x 12" SMOOTH <br />12 <br />5� <br />8'-0" RIDGE VENT <br />F4 <br />— 1" x 4" SMOOTH <br />12 TEXTURED <br />{ I <br />5 TRIM / BAND <br />{ I � <br />6" FASCIA <br />l J (TYP) <br />T.O.P. <br />HDR HGT. <br />T <br />00 <br />TRIM BAND 2nd FIN. FLR.,,l <br />HEEL <br />CORBEL <br />LE <br />BEL <br />IEETEXTURED <br />CEMENTICIOUS <br />FINISH ON C.M.U. <br />1EM <br />JIM--R <br />FRONT ELEVATION - Al <br />12' RIDGE VENT <br />SCALE: 1 /4"= V-0" <br />. <br />T.O.P. <br />HDR HGT. <br />to <br />GABLE END VENT <br />SCALE: 3/4"=T-0" <br />1 <br />—I00 <br />- � 1 <br />N ' <br />I 00 <br />_ 2nd FIN. FLR.J - <br />Mi� <br />T.O.M. <br />HDR HGT. <br />N• <br />_ F.FL. <br />LEFT ELEVATION <br />- Al <br />1 /4"=1'-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />"G.C. VERIFY ROOF PITCH" <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />"ELECTRICAL SPECIFICATION NOTES' <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portland cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Attic Ventilation <br />Attic Ventilation to be in compliance with the Florida Building Code 6th Edition <br />(2017) Residential R806. <br />The Minimum net free ventilating area shall be 1/150 of the area of the vented <br />space. The ventilating area may be reduced to 1/300 provided that at least 40% <br />but no more than 50% of the required ventilation is provided in the upper portion of <br />the space to be ventilated.Upper ventilators shall be located no more than 3 feet <br />(measured vertically) below the ridge or highest point of the space, with the <br />balance of the required ventilation provided by eave or cornice vents. <br />**CALCULATIONS BASED ON THE FOLLOWING VALUES, SEE ROOF PLAN** <br />(Values to be verified with Manufacturer Specifications) <br />• RIDGE VENTS 15 SQ. IN. OF NET FREE AREA / LINEAR FT. <br />• OFF -RIDGE VENTS 138 SQ. IN. OF NET FREE AREA / UNIT <br />• SOFFIT VENTS 7 SO. IN. OF NET FREE AREA / SQ. FT. <br />a <br />ui... <br />uL.- <br />0 0 <br />m <br />z <br />z 0 <br />J M <br />a <br />M <br />z <br />N o <br />Oro <br />LL' O <br />Qn <br />.J <br />_ <br />Ln <br />�Ln = 8 <br />(� <br />C) m <br />i_I., m �— [2 E <br />0 <br />U o N <br />N N <br />M W <br />o <br />o w <br />n a <br />Z W O M2 <br />U) �Zo <br />H ti o <br />a w <br />y Z <br />aw <br />LY zUA <br />c�aA 0 0 <br />Z_ QLLM <br />III a <br />r <br />> d <br />c <br />U <br />4101,, O� OFESS\p ``\\N <br />lel®'f <br />11111111151\m <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />co <br />w <br />19 <br />co <br />o <br />Z <br />LL_J <br />E u <br />z a <br />o, <br />�� <br />da <br />�° <br />0 <br />O E <br />N¢o <br />¢o <br />a <br />WW <br />L <br />(� <br />C <br />Z <br />� < <br />U <br />�m <br />0 <br />m0 <br />Z <br />W <br />J <br />t!) <br />N <br />F d <br />o$d <br />�w <br />sW <br />z Z <br />g0 <br />oz <br />=3 <br />CD <br />CO <br />�w <br />O� <br />� o <br />a r <br />�+ <br />o� <br />°� <br />`o <br />M <br />L <br />W <br />c <br />N <br />co <br />O <br />/.-. <br />/C 0 <br />V <br />oo <br />■� z C:)oO <br />LO <br />tV <br />Ln <br />Q <br />�-- <br />N <br />c N MCc) N <br />0 <br />f6 <br />z <br />C <br />7 O y <br />E <br />`m <br />C <br />aU <br />°� < p <br />-1 <br />JOB NO: 19-5903 <br />SCALE : AS NOTED <br />SHEET NO. <br />3.1 <br />r <br />