t <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />METER <br />MAIN <br />0 <br />200 amp <br />150 amp <br />POWER CO. FEED — <br />INTERSYSTEM <br />BONDING o <br />TERMINATION PER 7� <br />NEC 14, 250.94 <br />NEMA 1 <br />200 AMP <br />#14 copperto lights & outlets <br />#12 copperto 20 amp ckts <br />#10-2 copper to WH <br />#10.3 copper to Dryer <br />or 4/0 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />wP <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />rOr <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />Pa <br />PUSH BUTTON SWITCH (OPTIONAL) <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />Owl <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT, CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />( J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />H.B. <br />LP AC PAD ___ GFI _ ' ______ • ____GFI _ <br />OPT. REF. <br />DISC. - 80 FLEX <br />WP =E) I T <br />GFI I \ GFI I <br />FAMILY R M ` PENDANT AS r 11 ,_ j ' / , 'A <br />PER SPECS <br />I I D.W.D W I L H ROUGH -IN FOR <br />I I _LEI OPT. CLG. FAN/ <br />\ -z' ` CAFE j LIGHT PRE -WIRE <br />-1 \ ROUGH -IN FOR-,, ` GFI i i I .. _ <br />OPT. CLG. FAN/ \ - <br />�� / LIGHT PRE -WIRE <br />\ la .... <br />GFI U.C. SWITCH <br />' I FOR DISPOSAL <br />I I DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />j HOOD PER SPECS <br />F R <br />PATIO I C.M D <br />CH - co 4= ni <br />WP \ - ----- <br />GFI — <br />---- — — — P \ GFI@44" <br />C.M 1 16 <br />- - - - - A.F.F. <br />S.D <br />-- -- 15 <br />GFI @ 44" -------- <br />14 \ - <br />A.F.F.\ <br />FLR.--- \ I <br />Pj. <br />OWNERS SU fE 2 CAR�GARAGEI <br />i J I <br />-----------� FI @ 44" \ <br />I <br />I I I A.F.F. <br />G � GARAGE <br />I LIGHT AS GFI FOR <br />ROUGH -IN FOR GAR, DOOR <br />OPT. CLG. FAN/ I i PER SPECS PREWIRE <br />LIGHT PRE -WIRE ' I I <br />I I <br />I <br />I I <br />I I I <br />I I I <br />W.I.C. I <br />0 <br />VERIFY LOCATION <br />--' VP L_________- ELECTRICAL PANEL I GFI@44"A.F.F. <br />dh c-i IRRIGATION — <br />RECEPT. / VERIFY METER H.B. <br />FOR ALARM ___/ LOCATION WITH <br />SYSTEM BUILDER <br />FI <br />�I(LIGNT AS <br />PER EI <br />WP I <br />GFI <br />ENTRY <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />0 O <br />O <br />M <br />z o <br />v <br />J c] <br />M <br />z <br />CZ <br />Q) <br />� Y <br />f6 w o <br />j� <br />o Q <br />Fj <br />w <br />N <br />�N <br />fCi �- <br />U <br />W <br />E <br />8 <br />El <br />_ <br />U o' °� <br />C Y <br />=. <br />m <br />® C <br />a co 8 <br />�m <br />N N <br />b <br />42 Vf E M <br />Z LLI R <br />N a? J ayi 2 w <br />ii � Sty r` U W <br />v ° w <br />LY y ti z z a <br />LY a <br />V <br />0 <br />Z 0 �o< a <br />E Orl <br />W a�`MQ <br />umZ <br />U O� <br />❑❑ <br />rn <br />0 <br />CN <br />M <br />00 <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />co <br />M <br />coo <br />�W <br />z Z <br />S <br />L <br />o E <br />E S <br />wo <br />uj <br />� <br />Z& <br />Z® <br />C73 <br />¢Z <br />� <br />_ <br />O <br />2OU <br />XU <br />a¢ <br />o <br />U'O <br />o¢ <br />dz <br />N <br />ao <br />¢ <br />¢� <br />a% r✓ <br />ra <br />CO O <br />- c <br />Z <br />r <br />�m <br />0 <br />.0 <br />0, <br />Z> F <br />Z <br />ZU5 <br />-J <br />¢ 0 <br />20 <br />Z <br />U1 <br />� ?, <br />Q <br />~O <br />O <br />O <br />U <br />a <br />�w <br />W <br />U <br />wLL <br /><o <br />oWE <br />�— <br />�3 <br />a <br />;o <br />� <br />V <br />Z. <br />a <br />UO <br />�O0 <br />> M <br />^L <br />\/ <br />LO <br />c <br />N <br />�-. <br />co <br />-j <br />O <br />Q <br />C 0 0) <br />N <br />/11 m -10 <br />� <br />� -� 0) <br />r <br />00 <br />00 <br />Z o <br />L0 <br />N <br />2 Lo cc)0 <br />r <br />M N <br />o <br />Z <br />E <br />�n <br />a <br />E • • <br />U Q p <br />JOB <br />NO: 19-5903 <br />SCALE : AS NOTED <br />SHEET NO. <br />4.0 <br />