My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
3208 Kresterbrooke Ln
Zephyrhills
>
Building Department
>
Building Plans
>
3208 Kresterbrooke Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:09:27 AM
Creation date
2/19/2025 8:59:00 AM
Metadata
Fields
Template:
Building Plans
Street #
3208
Location
Kresterbrooke Ln
Contractor
Lennar Homes
Building Plans - Permit #
20293
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a=i <br />s <br />00 <br />0 <br />N <br />N <br />a <br />it <br />CD <br />x <br />DO <br />0 <br />J <br />N <br />m <br />CD <br />E <br />0 <br />x <br />t" <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />MO <br />200 amp <br />150 amp <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 <br />NEMA1 <br />200 AMP <br />14 copper to lights & outlets <br />12 copper to 20 amp ckts <br />10-2 copper to WH <br />10-3 copper to Dryer <br />or 410 SER Alu <br />4 Bare Cu Ground <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general) <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 42" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC, 406.11 <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2017 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' if the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlests shall not be required on a wall directly behind a range or sink to fulfill <br />the requirement for an outlet every 24". The width of the sink or range is not to be included in the <br />spacing of the outlets unless the distance from the sink or range is greater the 12" for straight counter <br />tops and 18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />DUPLEX OUTLET ABOVE COUNTER <br />FfT <br />WEATHERPROOF DUPLEX OUTLET <br />W.P. <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />G.F.I. <br />HALF -SWITCHED DUPLEX OUTLET <br />® SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />'4, _ <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />P.C. <br />LIGHT FIXTURE WITH PULL CHAIN <br />TRACK LIGHT <br />—� <br />FLOURESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />® D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />0 <br />PUSHBUTTON SWITCH (OPTIONAL) <br />SD <br />SMOKE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />]M <br />ELECTRIC METER <br />awl_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />SPEAKER (OPTIONAL) <br />^®^ <br />ROUGH -IN FOR OPT. CEILING FAN <br />'✓ J <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />I <br />C.M <br />r Y )�I <br />PA IO CAFE <br />WID N.B. <br />GFI DISC. <br />OWNER'S SW� ITE <br />T <br />ROUGH -IN FOR / <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE / <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />• .. _ LIEN <br />• <br />1. Vjl <br />IN <br />If <br />FAMILY RM <br />ROUGH -IN FOR <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />GFI �- <br />GFI C —---------] GFI <br />i i- -- I <br />I I I <br />' I D.W. <br />L___J <br />INK / DIS I <br />T \ <br />PENDANT AS <br />PER SPECS \ <br />T <br />LO <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />HOOD PER SPECS <br />JIC <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H.B. <br />IRRIGATION <br />VERIFY LOCATION GFI @ 44" A.F.F. <br />W.H. ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOM <br />GFI <br />GFI @ 44" <br />A.F.F. <br />I <br />I <br />_ I <br />I II I <br />I <br />I <br />I I 11 1 <br />— / <br />GFI @ 44" <br />A.F.F. <br />ii <br />ill ������I,%11l11111111111111111111�111111111111 <br />r <br />w _, • I� <br />•. _ <br />BEDROOM 2 <br />BEDROOM 4 <br />BEDROOM ■, n <br />I -• FOR El N."-• <br />�■ • •- <br />"14/- <br />PRE -WIRE FANI <br />��IGHT PRE -WIRE <br />LIGHT 11 `1 ' <br />I :••- <br />• 1� .. <br />MAIN FLOOR ELECTRICAL PLAN <br />SCALE: %4"=1'-0" <br />Z o <br />_ C> <br />Z � <br />Q <br />J <br />Vn) (� <br />, <br />� �7 <br />w <br />Q <br />OLn LLJ <br />Vi <br />to 0 <br />i� <br />U <br />LU <br />E <br />03 M M <br />m <br />8 <br />Mal <br />T 'C <br />0 0 O <br />= N <br />N <br />U <br />L E W <br />00 <br />:5 - cu <br />O Y <br />III II11 (D <br />ffuVuV PP <br />O) <br />C0 aO <br />�C <br />Q O <br />B I <br />N -C <br />*71 <br />C=> <br />N <br />N <br />Z O <br />Z M <br />M LL <br />� N �/ Z_Mr— <br />U) <br />LL <br />if (n fV <br />W - m N <br />ai <br />W <br />!Z W <br />a <br />W _ <br />Z 0 cr) <br />z <br />EI <br />Z " <br />ix C> <br />W aQM� <br />0 <br />o <br />CD <br />To the best of the Engineer's knowledge, information, and <br />belief, the structural plans and specifications contained <br />within these drawings comply with the 2017 Florida <br />Building Code- Residential 6th Edition. Engineer's <br />signature and seal is only for the structural engineering <br />portions of the drawing pages bearing Engineer's signature <br />and seal. <br />O <br />Z <br />n <br />0 <br />.N <br />� O <br />H M O <br />M <br />Q U-) fo <br />0^ <br />�'- U_ <br />CL <br />U ru <br />00 <br />Q <br />§ fu <br />Z <br />W <br />J <br />to <br />oz <br />Zaa <br />Z <br />J <br />oQ-o <br />ZWw� <br />M � z <br />J <br />�2Orn <br />< <br />U <br />o-woo <br />� o <br />L <br />Z <br />Zz <br />> <br />V • <br />i Z <br />M <br />J <br />vt 3 <br />w <br />o <br />Z <br />UU <br />= <br />O <br />Q <br />a Lu <br />Q <br />>� <br />a90 <br />LL <br />Q <br />Z Lu � J <br />Q <br />Z <br />O 'L W <br />209W <br />gut <br />Z <br />J <br />a�oZ <br />LJ J <br />toQZ o <br />r-I <br />M <br />Q <br /><( <br />Z <br />W i5 � <br />�uJZ <br />Z <br />�ce <br />o' <br />N <br />Z <br />� <br />_ <br />Z <br />J0 <br />¢W <br />0 <br />00 <br />,-I <br />a <br />(n <br />SCALE : AS NOTED <br />DATE : 3/30/2018 <br />TECH: MJAM ES <br />VERSION NO- 4nO <br />SHEET NO. <br />4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.